Engineering topics
Blednykh, A
Publications and source records attributed to Blednykh, A.
NSLS-II INJECTION STRAIGHT DIAGNOSTICS
The ultra-bright light source being developed by the NSLS-II project will utilize top-up injection and fine tuning of the injection process is mandatory. In this paper we present the diagnostics installed in the injection straight. Its use for commissioning and tuning of the injection cycle is also described. The NSLS-II storage ring will utilize a 9.3 meter long injection straight section shown in Fig. 1. Injection will be preformed with two septa (one pulsed, one DC) and four kickers. The stored beam will be shifted towards the pulsed septum up to IS mm and the nominal distance between centers of the injected and the bumped beam is 9.5mm. The NSLS-II beam position monitors will have turn-by-turn and first-turn capabilities and will be used for the commissioning and tuning the injection process. However, there are three additional BPMs and two beam intercepting OTR screens (flags) installed in the injection straight.
Loss Factor of Tapered Structures for Short Bunches
Using the electromagnetic simulation code ECHO, we have found a simple phenomenological formula that accurately describes the loss factor for short bunches traversing an axisymmetric tapered collimator. In this paper, we consider tapered collimators with rectangular cross-section and use the GdfidL code to calculate the loss factor dependence on the geometric parameters for short bunches. The results for both axisymmetric and rectangular collimators are discussed. The behaviour of the impedance of tapered structures for very short bunches in the optical regime has been determined in refs. [10,11]. Here, for the loss factors for two particular geometries, we have studied the departure from the optical regime behaviour as bunch length is increased. In both cases, the ratio of the loss factor for the tapered collimator to the loss factor in the optical regime is a function only of the scaling parameter {sigma}L/d{sup 2}. The fact that the bunch length a and the taper length L appear as a product is consistent with the recent scaling derived by Stupakov in ref. [12], since there is only a weak dependence on g. One noteworthy fact that is not a priori expected is that only the larger radius or vertical half-aperture d appears. The reduction factor is independent of b. Moreover, it is striking that the specific form involving the arctan given in Eq. (5) holds for both geometries, with only the coefficient {mu} differing by a factor of {approx}2 for flat vs round. This suggests that there may be a useful phenomenological form for more general geometries which may follow from natural extensions of Eq. (5). This possibility is presently being investigated.
NSLS-II BPM System Protection from Rogue Mode Coupling
Rogue mode RF shielding has been successfully designed and implemented into the production multipole vacuum chambers. In order to avoid systematic errors in the NSLS-II BPM system we introduced frequency shift of HOM's by using RF metal shielding located in the antechamber slot of each multipole vacuum chamber. To satisfy the pumping requirement the face of the shielding has been perforated with roughly 50 percent transparency. It stays clear of synchrotron radiation in each chamber.
Short pulse generation by laser slicing at NSLSII
We discuss an upgrade R&D project for NSLSII to generate sub-pico-second short x-ray pulses using laser slicing. We discuss its basic parameters and present a specific example for a viable design and its performance. Since the installation of the laser slicing system into the storage ring will break the symmetry of the lattice, we demonstrate it is possible to recover the dynamical aperture to the original design goal of the ring. There is a rapid growth of ultrafast user community interested in science using sub-pico-second x-ray pulses. In BNL's Short Pulse Workshop, the discussion from users shows clearly the need for a sub-pico-second pulse source using laser slicing method. In the proposal submitted following this workshop, NSLS team proposed both hard x-ray and soft x-ray beamlines using laser slicing pulses. Hence there is clearly a need to consider the R&D efforts of laser slicing short pulse generation at NSLSII to meet these goals.
STRIPLINE KICKER DESIGN FOR NSLS2 STORAGE RING
In the NSLS2 storage ring, there are four stripline kickers/pickups. Two long striplines with electrode length of 30cm will be used as bunch-by-bunch transverse feedback actuators. Two short stripline kickers/pickups with 15cm length will mainly used for tune measurement excitation or signal pickup for the beam stability monitor. High shunt impedance of the long stripline kickers is demanded to produce 200 {micro}s damping time. Meanwhile the beam impedance should be minimized. The design work for these two types of stripline is discussed in this paper. NSLS2 is a third-generation light source under construction at Brookhaven National Laboratory. The machine will have < 1nm.rad horizontal emittance by using weak dipoles together with damping wigglers. For the storage ring of 792m circumference, geometric impedance, resistive wall impedance and ion effects are expected to be significant. A transverse bunch-by-bunch feedback system has been designed to suppress the coupled bunch instabilities. More information can be found in previous paper.
ELECTROMAGNETIC FIELD MEASUREMENT OF FUNDAMENTAL AND HIGHER-ORDER MODES FOR 7-CELL CAVITY OF PETRA-II
The booster synchrotron for NSLS-II will include a 7-cell PETRA cavity, which was manufactured for the PETRA-II project at DESY. The cavity fundamental frequency operates at 500 MHz. In order to verify the impedances of the fundamental and higher-order modes (HOM), which were calculated by computer code, we measured the magnitude of the electromagnetic field of the fundamental acceleration mode and HOM using the bead-pull method. To keep the cavity body temperature constant, we used a chiller system to supply cooling water at 20 degrees C. The bead-pull measurement was automated with a computer. We encountered some issues during the measurement process due to the difficulty in measuring the electromagnetic field magnitude in a multi-cell cavity. We describe the method and apparatus for the field measurement, and the obtained results.
PROGRESS WITH NSLS-II INJECTION STRAIGHT SECTION DESIGN
The NSLS-II injection straight section (SR) consists of pulsed and DC bumps, septa system, beam trajectory correction and diagnostics systems. In this paper we discuss overall injection straight layout, preliminary element designs, specifications for the pulsed and DC magnets and their power supplies, vacuum devices and chambers and diagnostics devices. Prior to selecting the current 'conventional' design of the injection straight section we analyzed an option of injection via pulsed multipole pioneered at PF-AR. We found that this promising approach was not suited to the NSLS-II storage ring optics, since it would require a impractically compact arrangement of the injection straight section components and a complex modification of the transport line optics due to the strong focusing of the injected beam passing off the pulsed multipole axis. In addition, the requirement for a small injection transient of the stored beam orbit severely constrains the vertical alignment tolerance of the pulsed multipole. The design of the NSLS-II injection straight section is now completed with exception of transition chamber details, which will be adjusted to accommodate the actual layouts of the pulsed magnets.
Study of Single and Coupled-Bunch Instabilities for NSLS-II
We study single and coupled-bunch instabilities for the NSLS-II storage ring with a recently developed parallel tracking code. For accurate modelling of the coupled-bunch instability, we investigate improvements to current point-bunch models to take into account finite bunch-size effects. Accurate modelling of single and coupled-bunch instabilities is of crucial importance for the machine performance of light sources such as NSLS-II, that provide high current beams. The complexity of the model consists in the accurate calculation of the impedance of the various components of the ring that can excite single and multibunch instabilities via short and long range wakefields. Moreover, a full account of the coupling between transverse and longitudinal dynamics must be taken into account to study effects such as chromaticity and Landau cavity effects. A parallel algorithm for the study of single and coupled-bunch instabilities has been implemented in a particle tracking code. The theoretical framework for single bunch instabilities is the same used in the code TRANFT, while for coupled-bunch instabilities a self-consistent algorithm has been implemented to allow the study of finite bunch-size effects and multibunch effects in arbitrary filling modes. In this paper we present numerical studies of the microwave instability for NSLS-II and discuss the self-consistent algorithm for simulation of coupled-bunch instabilities.
Rogue Mode Shileding in NSLS-II Multipole Vacuum Chambers
Modes with transverse electric field (TE-modes) in the NSLS-II multipole vacuum chamber can be generated at frequencies above 450MHz due to its geometric dimensions. Since the NSLS-II BPM system monitors signals within 10 MHz band at RF frequency of 500 MHz, frequencies of higher-order modes (HOM) can be generated within the transmission band of the band pass filter. In order to avoid systematic errors in the NSLS-II BPM system, we introduced frequency shift of HOMs by using RF metal shielding located in the antechamber slot. We demonstrated numerical modeling and experimental studies of the spurious TE modes in the NSLS-II vacuum chambers with antechamber slot. Calculated frequencies of TE-modes in considered chambers with and without RF shielding were verified experimentally. Flexible BeCu RF shielding inside each chamber at proper location shifts frequencies of H{sub 10p}-modes above {approx}900MHz, except chambers S6 odd and even. These chambers need special attention because of synchrotron radiation from downstream magnets. S6 odd multipole vacuum chamber needs to be measured and the RF shielding length has to be optimized. RF shielding looks adequate for baseline design. Fifty percent of open space provides adequate pumping speed.
Loss factor for short bunches in azimuthally symmetric tapered structures
We use the program ECHO to study numerically the loss factor of axisymmetric cavities and collimators with and without tapering. We consider a Gaussian driving bunch of length {sigma}, and structures with inner radius b, outer radius d, cavity gap (or collimator inner length) g, and taper length L. In all cases we consider a short bunch with {sigma}<<b. For the untapered structures (L=0), in certain regimes, we describe our numerical results using the known expressions for a step transition and for the diffraction model. In addition, we identify new regimes where g<{sigma} and/or d-b<{sigma}, for which the data must be described by new phenomenological expressions. For a tapered collimator with d-b>b, we present a phenomenological formula which accurately describes the dependence of the loss factor on the parameters {sigma}, b, d, and L. This formula also holds for a tapered cavity with g>d{sup 2}/{sigma} and d-b>b.
NSLS-II Beam Diagnostics Overview
A new 3rd generation light source (NSLS-II) is in the early stages of construction at Brookhaven National Laboratory. The NSLS-II facility will provide ultra high brightness and flux with exceptional beam stability. It presents several challenges for diagnostics and instrumentation, related to the extremely small emittance. In this paper, we present an overview of all planned instrumentation systems, results from research and development activities; and then focus on other challenging aspects.
Microwave Instability Simulations for NSLS-II
Potential-well distortion and the microwave instability in the NSLS-II storage ring are investigated. The longitudinal wakepotential is calculated as a sum of the contributions due to vacuum chamber components distributed around the ring. An approximation to the wakepotential for a 0.05-mm charge distribution length, much shorter than the 4.5-mm length of the unperturbed circulating bunch, is used as a pseudo-Green's function for beam dynamics simulations. Comparison of particle tracking simulations using the TRANFT code with the Haissinski solution shows good agreement below the instability threshold current. Above threshold two regimes are observed: (1) energy spread and bunch length are time-dependent (saw tooth behavior); (2) both are time-independent.
Infrared Extraction Change for the NSLS-II Storage Ring
The short- and long-range wakepotentials have been studied for the design of the infrared (IR) extraction chamber with large full aperture: 67mm vertical and 134mm horizontal. The IR-chamber will be installed within a 2.6m long wide-gap bending magnet with 25m bend radius. Due to the large bend radius it is difficult to separate the light from the electron trajectory. The required parameters of the collected IR radiation at the extraction mirror are {approx}50mrad horizontal and {approx}25mrad vertical (full radiation opening angles). If the extraction mirror is seen by the beam, resonant modes are generated in the chamber. In this paper, we present the detailed calculated impedance for the design of the far-IR chamber, and show that placing the extraction mirror in the proper position eliminates the resonances. In this case, the impedance reduces to that of a simple tapered structure, which is acceptable in regard to its impact on the electron beam.
Impedance Calculations for the NSLS-II Storage Rings
Impedance of two vacuum chamber components, Bellows and BPM, is considered in some detail. In order to avoid generation of Higher-Order Modes (HOM's) in the NSLS-II bellows, we designed a new low-impedance RF shielding consisting of 6 wide and 2 narrow metal plates without opening slots between them. The short-range wakepotential has been optimized taking into account vertical offset of RF fingers from their nominal position. The results were compared with data of bellows designed at other laboratories. Narrow-band impedance of the BPM Button has been studied. TE-modes in the BPM button were suppressed by a factor of 8 by modification of existing housings. Two new types of housings are shown. The total impedance of the NSLS-II storage ring is discussed in terms of the loss factor and the vertical kick factor for a 3mm-Gaussian bunch.
Results from a Test Fixture for button BPM Trapped Mode Measurements
A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1) Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.