Improvements of NSLS-II X-ray Diagnostic Beamlines
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Blednykh, Alexei.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A fast and precise technique of local impedance measurement has been developed and tested at NSLS-II. This technique is based on in-phase sine-wave (AC) excitation of four fast correctors adjacent to the vacuum chamber section, impedance of which is measured. The beam position is measured using synchronous detection. Use of the narrow-band sine-wave signal allows us to improve significantly the accuracy of the orbit bump method. Beam excitation by fast correctors results in elimination of the systematic error caused by hysteresis effect. The systematic error caused by orbit drift is also eliminated because the measured signal is not affected by the orbit motion outside the excitation frequency range. In this article, the measurement technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented.
Possible installation of a long low-gap in-vacuum undulator in the NSLS-II storage ring could result in several impedance-related and beam lifetime issues. High impedance of the low-gap undulator can result in beam instabilities and beam-induced overheating of the undulator itself. These issues have been preliminary studied using analytical formulae, computer simulations and experience of operations with existing in-vacuum undulators. Depending on the device location, the minimum gap and the overall ring-average residual gas pressure, an in-vacuum undulator (IVU) may appreciably shorten the elastic gas scattering component of the beam lifetime. When the latter becomes comparable to the Touschek lifetime, a significant reduction of the total beam lifetime will occur. Here this effect is studied by applying some well-known analytical formulas, as well as insights from NSLS-II operating experience. Finally, the issue of IVU radiation damage also needs to be looked at, and potentially addressed with a dedicated collimation system.
An analytical expression of the low-frequency quadrupole impedance for undulators and wigglers is derived and benchmarked against beam-based impedance measurements done at the 3GeV NSLS-II storage ring. The adopted theoretical model, valid for an arbitrary number of electromagnetic layers with parallel geometry, allows to calculate the quadrupole impedance for arbitrary values of the magnetic permeability $μ_r$. In the comparison of the analytical results with the measurements for variable magnet gaps, two limit cases of the permeability have been studied: the case of perfect magnets ($μ_r$ → $\infty$), and the case in which the magnets are fully saturated ($μ_r$ = 1).
Not Available
The NSLS-II storage ring (SR) phase I commissioning has been successfully completed in May 12, 2014. In accordance to the project milestone, 25 mA average current was achieved in the storage ring with PETRA III 500 MHz 7-cell PETRA-III RF cavity but w/o ID’s and Landau cavities. In about 5 weeks we delivered a 3 GeV beam to the ring injection straight section, made the 1st turn around the ring, achieved hundreds of turns optimizing injection, stored beam having sextupoles and RF turned ON. Injection efficiency was achieved 95%, close orbit rms value is ~100 um, tune and chromaticity were measured and adjusted as desired, and beam lifetime was a few hours depending on the stored beam current. This report consists of a summary, a chronological part, the injector system performance in Ch3, SR commissioning experience in Ch4 and the outlook of remaining work in Ch5. The SR commissioning experience includes the software experience, hardware (timing, diagnostics, RF, vacuum, PS) operation experience, the strategy for initial injection beam to the stored beam, measurement of the linear optics and control to the desired value, nonlinear beam dynamics study, beam instability study, the subsystem reliability and fault study at different scenarios.
Explore the source record for details and available documents.
To estimate the vertical impedance of more complex geometry as an In-Vacuum Undulator we crosschecked first the results for simplified geometries. Axially symmetric tapered structures and rectangular structures are under discussion. Comparisons of analytical results with numerical results obtained with the electromagnetic field solver GdfidL are presented. Intensive studies were carried out to determine the dependence of the wake potential and kick factor on the collimator’s geometric parameters. We discuss the relationship of our results to the earlier work of G. Stupakov.
We studied the coupled-bunch instability driven by a 7-cell PETRA-III cavity structure, which is considered to be installed in the commissioning Phase 1 in the NSLS-II storage ring at an average current of 25mA. For instability threshold calculations we used the parameters of the bare lattice (no DW’s and Landau cavities). The transverse and longitudinal coupled-bunch instabilities can be driven by the higher order modes (HOM’s) of the 7-cell PETRA-III cavity structure. In the case of uniform filling the beam is longitudinally stable, and transversely unstable at zero chromaticity. To increase the transverse instability threshold we studied the stabilizing effect of the slow head-tail instability at positive chromaticity. We assume the slow head tail effect is driven by a broadband resonator impedance. In the case of all RF buckets filled (M=1320 bunches, N=3.1x10 8 particles per bunch) the beam is unstable for values of the chromaticity in the range [0 2]. To increase the damping provided by the slow head-tail effect, we discuss fillings with a larger number of particles per bunch. We analyze uniform filling configurations with M=132 (N=3.1x10 9 ) and M=66 (N=6.2x10 9 ). We also discussed HOM’s frequencies detuning based upon temperature change as a cure of the coupled-bunch instabilities, and proposed working points to make the 7-cell PETRA-III cavity structure stable under coupled-bunch interaction.