Radiation Hot Spot Seasonal Variation on UF6 Cylinders
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Bledsoe, Keith.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.
Material Control and Accountability (MC&A) programs track masses of materials flowing through production processes, where some material remains in process equipment as holdup. Quantification of these masses using gamma emissions typically involves usage of a well characterized radiation detector and assumptions of geometric configuration to constrain detection efficiencies, where the Generalized Geometry Holdup (GGH) method is often used. Uncertainties on the order of ±50% are observed, where the difficulties arise based on the asymmetric and gradient distributions of material that do not fall within the bounds of GGH. Gamma imagers provide a possible means to improve this geometric knowledge. This work describes the process used in creating a series of mass standards to aid the development of imaging algorithms for quantification.
Mass quantification using standoff gamma detection is a logical progression for MC&A applications in uranium processing facilities. While obtaining a ground truth from physical collection and weighing of masses is ideal and routine, it poses a logistical problem from both a standpoint of ALARA programs as well as interruptions to operations. The standard approach is the Generalized Geometry in Holdup (GGH) method that can apply for many cases where geometries of the holdup match simulated models; however, there are many cases where a model may not exist or a feature of the holdup geometry is such that it does not match a model particularly well.1 Gamma imaging at standoff distances and outside process equipment has potential to address these shortcomings and improve mass estimations while reducing personnel exposure; however, algorithms still require a significant degree of benchmarking to build sufficient confidence in algorithms before displacing GGH in some procedures. This paper presents the creation of a set of laboratory standards of depleted U3O8 in fixed size containers covering a range of masses and effective thicknesses up to the infinite thickness for the 185-keV line. These blocks are identically sized aluminum boxes loaded such that a thin, flat face is placed towards the imager, while the back side contains closed cell foam to apply pressure to keep the powder in a fixed position at the front face as the sources are manipulated for measurements. Included is an analysis of the mass estimation using a commercially available Compton imaging instrument where multiple geometries are created showing limitations in current methodologies.
Deposits in commercial uranium processing facilities of interest to nuclear safeguards are predominantly low enriched uranium (LEU). The shapes and sizes of holdup deposits can vary significantly, thus making it difficult to model the deposits accurately for calibration purposes. This presents a challenge to currently employed methods such as the Generalized Geometry Holdup (GGH) that rely on quantifying 235U mass by simplifying deposit shapes as a point, a line, or an area. In this work, gamma ray imaging using high energy resolution Germanium Gamma Imagers (GeGI™) is employed to determine the distribution of uranium inside the source containment. Two types of imaging methods are employed; coded-aperture imaging and Compton imaging. Gamma-ray emissions seen in different regions of the image are quantified using an inverse gamma-ray transport solver being developed at ORNL. Using measured data, the inverse method will be used to solve for unknown source parameters such as source matrix thickness, density, and attenuation due to container wall and shielding. The intrinsic efficiency of the detector is determined based on a library of built-in response functions and key dimensions of the detector (e.g., thickness and radius of the detector crystal). Measurements are performed in both imaging modalities using uranium sources of well-known masses and enrichments configured inside mocked-up holdup fixtures. Results from the two imaging modalities are intercompared. The paper presents preliminary results of the imaging measurements and the progress made in the computational methods to quantify uranium mass.