Search NASA⌕ Search

Engineering topics

Blesener, I C

Publications and source records attributed to Blesener, I C.

Initial experiments using radial foils on the Cornell Beam Research Accelerator pulsed power generator

A novel technique involving radial foil explosions can produce high energy density plasmas. A current flows radially inward in a 5 mum thin aluminum foil from a circular anode, which contacts the foil on its outer rim, to the cathode, which connects to the foil at its geometrical center. When using small 'pin' cathodes (approx1 mm in diameter) on a medium size pulsed-current generator such as the Cornell Beam Research Accelerator, the central magnetic field approaches 400 T, yielding magnetic pressures larger than 0.5 Mbar. While the dynamics is similar to radial wire arrays, radial foil discharges have very distinct characteristics. First a plasma jet forms, with densities near 5x10{sup 18} cm{sup -3}. JxB forces lift the foil upward with velocities of approx200 km/s. A plasma bubble with electron densities superior to 5x10{sup 19} cm{sup -3} then develops, surrounding a central plasma column, carrying most of the cathode current. X-ray bursts coming from the center of this column were recorded at 1 keV photon energy. As the magnetic bubble explodes, ballistic plasma projectiles form and escape with velocities exceeding 300 km/s. Laser shadowgraphy and interferometry, gated extreme ultraviolet imaging and miniature Bdot probes are used to investigate the magnetohydrodynamics properties of such configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axial x-ray backlighting of wire-array Z-pinches using X pinches

For the first time, a geometry has been developed to allow for an axial imaging system for wire-array Z-pinch experiments that produce high-resolution x-ray images. The new geometry required a significant redesign of the electrode hardware. Calibrated areal density measurements of the Z-pinch plasma including wire cores, coronal plasma, streaming plasma, and the precursor were obtained. The system used eight-wire molybdenum (Mo) X pinches in series with and directly below the Z-pinch axis to provide micron-scale x-rays sources for point-projection radiography. The images formed on the x-ray sensitive film had a 15 mm diameter field of view at the center height of the array and a magnification of about 7.5:1. Titanium (Ti) filters in front of the film transmitted radiation in the spectral range of 3-5 keV. For calibration, a separate film with the same thickness Ti filter was placed the same distance from the X pinch. This film had an unobstructed path that bypasses the Z-pinch but included step wedges for calibration of the Z-pinch plasma. The step wedges had thicknesses of tungsten (W) ranging from 0.015 to 1.1 {mu}m to obtain areal density measurements of the W plasma from the wire-array. Images had subnanosecond temporal resolution and about 10 {mu}m spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Azimuthally correlated ablation between z-pinch wire cores

Azimuthally correlated wire core ablation was compared for closely spaced versus widely spaced wires in a 1 MA Z-pinch. X-ray point-projection diagnostics revealed that 240 {mu}m spaced wires exhibited a correlation coefficient approaching unity in both real space and in k-space. This correlated ablation between wires at a fixed axial location is believed to occur due to an enhanced, localized Joule heating. Wires separated by 2.47 mm or greater were uncorrelated in real space, but correlated in k-space, indicating the ablation structure between wires was shifted in phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the effect of current rise time on the formation of the precursor column in cylindrical wire array Z pinches at 1 MA

The limited understanding of the mechanisms driving the mass ablation rate of cylindrical wires arrays is presently one of the major limitations in predicting array performance at the higher current levels required for inertial confinement fusion (ICF) ignition. Continued investigation of this phenomenon is crucial to realize the considerable potential for wire arrays to drive both ICF and inertial fusion energy, by enabling a predictive capability in computational modeling. We present the first study to directly compare the mass ablation rates of wire arrays as a function of the current rise rate. Formation of the precursor column is investigated on both the MAPGIE (1 MA, 250ns [Mitchell et al., Rev. Sci. Instrum. 67, 1533 (1996)]) and COBRA (1 MA, 100ns [Greenly et al., Rev. Sci. Instrum. 79, 073501 (2008)]) generators, and results are used to infer the change in the effective ablation velocity induced by the rise rate of the drive current. Laser shadowography, gated extreme ultraviolet (XUV) imaging, and x-ray diodes are used to compare the dynamical behavior on the two generators, and X-pinch radiography and XUV spectroscopy provide density evolution and temperature measurements respectively. Results are compared to predictions from an analytical scaling model developed previously from MAGPIE data, based on a fixed ablation velocity. For COBRA the column formation time occurs at 116{+-}5 ns and for Al arrays and 146{+-}5 ns for W arrays, with Al column temperature in the range of 70-165 eV. These values lie close to model predictions, inferring only a small change in the ablation velocity is induced by the factor of 2.5 change in current rise time. Estimations suggest the effective ablation velocities for MAGPIE and COBRA experiments vary by a maximum of 30%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Spectroscopy Experiments on the 500 kA XP Pulsed-Power Generator

Recent experiments on the 500 kA XP pulsed-power generator at Cornell University have explored the properties of optical spectra in single wires and wire arrays. In the single wire experiments, {approx}1% of the current from XP has been directed through the single wire. Spectra have been recorded using a half-meter spectrometer and a CCD camera located adjacent to the XP pulser. We are studying the visible spectra emitted by the wires and the background light from the machine hardware in order to identify the levels of current per wire for which visible spectroscopy might provide a means to measure magnetic field strength. We have also investigated the dependence of single wire visible spectra on the current, which was measured using a calibrated non-integrating Rogowski coil. UV and XUV diodes were employed to gather information about the temporal structure of the background and wire radiation. The line radiation in the spectra was recorded with wire currents at the few kA level. This is comparable to the first 10 ns of a 32-wire array experiment on 1 Ma generator and a 600-wire array at 20 MA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Current Rise-time on the Formation of Precursor Structures and Mass Ablation Rate in Cylindrical Wire Array Z-Pinches

We present the first study to directly compare the mass ablation rates of cylindrical wire arrays as a function of the current rise-rate. Formation of the precursor column is investigated on both the MAPGIE (1 MA, 250 ns) and COBRA (1 MA, 100 ns) generators, and results are used to infer the change in the mass ablation rate induced by the rise-rate of the drive current. Laser shadowography, gated XUV imaging and x-ray diodes are used to compare the dynamical behavior both generators, and x-pinch radiography and XUV spectroscopy and provide density evolution and temperature measurements respectively. Results are compared to predictions from an analytical scaling model based on a fixed ablation rate, and the close correlation achieved suggests that the effective ablation velocity is not a strong function of the current rise rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soldered Contact and Current Risetime Effects on Negative Polarity Wire Array Z-pinches

The Cornell University COBRA pulser is a nominal 1 MA machine, capable of driving up to 32 wire cylindrical Z-pinch arrays. COBRA can operate with variable current risetimes ranging from 100 ns to 200 ns (short and long pulse, respectively). Wires are typically strung with a 'press' contact to the electrode hardware, where the wire is loosely pulled against the hardware and held there to establish electrical contact. The machine is normally negative, but a bolt-on convolute can be used to modify the current path and effectively produce positive polarity operation at the load.Previous research with single wires on a 1-5 kA pulser has shown that soldering the wire, thereby improving the wire/electrode contact, and operating in positive polarity can improve the energy deposition into the wire and enhance wire core expansion. Negative polarity showed no difference. Previous experiments on the negative polarity, 20 MA, 100 ns Z accelerator have shown that improving the contact improved the x-ray yield.Cornell data were collected on 16-wire Aluminum Z-pinch arrays in negative polarity. Experiments were conducted with both short and long current pulses with soldered and no-soldered wire/electrode contacts. The initiation, ablation, implosion and stagnation phases were compared for these four conditions. Time dependent x-ray signals were measured using diodes and diamond detectors. An inductive voltage monitor was used to infer minimum current radius achieved, as defined by a uniform shell of current moving radially inward, producing a time dependent inductance. Total energy data were collected with a metal-strip bolometer. Self-emission data were collected by an XUV 4-frame camera and an optical streak camera.In negative polarity and with short pulses, soldering appeared to produce a smaller radius pinch and decrease variations in the x-ray pulse shape. The bolometer, laser backlighter, 4-frame and streak cameras showed negligible differences in the initiation ablation and implosion phases. X-ray yield was increased with soldered arrays in negative polarity with long pulses. The bolometer also showed a 50% increase in radial power emitted for soldered arrays. 4-frame images showed soldered arrays have a more pronounced 'Christmas Tree' effect originating from the cathode. The inductive voltage monitor showed, with both long and short pulses, that soldered and no-solder arrays reached the same minimum current radius at the same time. However, with long pulses soldered arrays radiate x-rays at the time of minimum current radius while no-solder array x-ray output is delayed by {approx}20 ns, resulting in decreased x-ray yield.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of the Axial Instability in Low Wire Number Wire Array Z-Pinches

We are investigating the development of the axial instability, a modulation of the size of the coronal plasma that develops around each wire in wire-array Z-pinches. The modulation is a result of nonuniform ablation of material from the relatively cold wire core. It has long been known that the wavelength of this modulation is constant late in time and, since it is unique to different materials, it has come to be known as the fundamental mode. In these experiments we imaged individual wires with laser shadowgraphy early in time primarily in low wire number, large wire diameter aluminum arrays for ease of viewing. We Observe the development of this modulation from the time of initiation of coronal plasma, obtaining its dominant wavelength and amplitude growth as a function of time. We also studied the instability on coiled wires, which modify the wire ablation mechanism and completely suppress the fundamental mode[Hall2008]. time is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modifying Wire Array Z-pinch Ablation Structure and Implosion Dynamics Using Coiled Arrays

Coiled arrays, a cylindrical array in which each wire is formed into a helix, suppress the modulation of ablation at the fundamental wavelength. Outside the vicinity of the wire cores, ablation flow from coiled arrays is modulated at the coil wavelength and has a 2-stream structure in the r,{theta} plane. Within the vicinity of the helical wires, ablation is concentrated at positions with the greatest azimuthal displacement and plasma is axially transported from these positions such that the streams become aligned with sections of the coil furthest from the array axis. The GORGON MHD code accurately reproduces this observed ablation structure, which can be understood in terms of JxB forces that result from the interaction of the global magnetic field with a helical current path as well as additional current paths suggested by the simulations. With this ability to control where ablation streamers occur, large wavelength coils were constructed such that the breaks that form in the wires had sufficient axial separation to prevent perturbations in the implosion sheath from merging. This produces a new mode of implosion in which the global instability can be controlled and perturbations correlated between all wires in an array. For large wavelength 8-wire coiled arrays, this produced a dramatic increase in x-ray power, equalling that of a 32-wire straight array. These experiments were carried out on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and the COBRA generator (1 MA, 100 ns) at Cornell University.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implosion dynamics and radiation characteristics of wire-array Z pinches on the Cornell Beam Research Accelerator

Experimental results are presented that characterize the implosion dynamics and radiation output of wire-array Z pinches on the 1-MA, 100-ns rise-time Cornell Beam Research Accelerator (COBRA) [J. B. Greenly et al., Rev. Sci. Instrum. 79, 073501 (2008)]. The load geometries investigated include 20-mm-tall cylindrical arrays ranging from 4 to 16 mm in diameter, and consisting of 8, 16, or 32 wires of either tungsten, aluminum, or Invar (64% iron, 36% nickel). Diagnostics fielded include an optical streak camera, a time-gated extreme-ultraviolet framing camera, a laser shadowgraph system, time-integrated pinhole cameras, an x-ray wide-band focusing spectrograph with spatial resolution, an x-ray streak camera, a load voltage monitor, a Faraday cup, a bolometer, silicon diodes, and diamond photoconducting detectors. The data produced by the entire suite of diagnostics are analyzed and presented to provide a detailed picture of the overall implosion process and resulting radiation output on COBRA. The highest x-ray peak powers (300-500 GW) and total energy yields (6-10 kJ) were obtained using 4-mm-diameter arrays that stagnated before peak current. Additional findings include a decrease in soft x-ray radiation prior to stagnation as the initial wire spacing was changed from 1.6 mm to 785 {mu}m, and a timing correlation between the onset of energetic electrons, hard x-ray generation, and the arrival of trailing current on axis - a correlation that is likely due to the formation of micropinches. The details of these and other findings are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗