Positive electrode processing for Hughes NiH2 cells
The basic procedures were developed for the manufacture of nickel cadmium batteries. An electrochemical impregnation in an aqueous ethanol solution is used in this process. Several additional controls were instituted for production of flight electrodes, including a Hughes controlled MCD, a solution reserved exclusively for the impregnation of Hughes positive electrodes a system of complete traceability for individual electrodes, an electrical characterization test to provide information on weight and capacity at the plaque level, and a stress test to provide data on capacity, weight, and physical parameters at the electrode level.