A radiation-hard, low-background multiplexer design for spacecraft imager applications

A possible multiplexer design for the focal plane for the Cassini Visible and Infrared Mapping Spectrometer (VIMS) is reviewed. The instrument's requirements for the multiplexed array are summarized. The VIMS instrument has a modest radiation-hardness requirement due to the trajectory and planetary environments in which the instrument will be required to operate. The total ionizing dose hardness requirement is a few tens of kilorads. A thin-gate oxide of a few hundred angstroms thickness is to be used. Field hardness is to be achieved by guard bands or hardened dielectric isolation. The design is argued to meet the low-noise and radiation-hardness required for imaging at Saturn. The design is versatile enough to provide double-correlated and double-uncorrelated sampling, which is accomplished in the signal processing electronics outside the focal plane.

Staller, Craig↗

InSb linear multiplexed FPAs for the CRAF/Cassini visible and infrared mapping spectrometer

This paper provides a review of a custom multiplexer circuit designed for use with a 256 element InSb linear array in the CRAF/Cassini VIMS instruments. The requirements, operation noise model and test results from a prototype 1 x 64 array are discussed. The infrared focal plane array (FPA) preliminary design and the impact of the new multiplexer on the instruments' predicted performance will be discussed. Emphasis will be placed on the multiplexer that was designed for the CRAF/Cassini missions. The FPA assembly combines electronic and optical components into a single hermetically sealed hybrid package. The detector configuration is that of a linear dual-multiplexed indium antimonide array with 256 elements, each 103 x 200 on 123-micron centers.

Niblack, Curtiss↗

Infrared focal plane design for the Comet Rendezvous/Asteroid Flyby and Cassini Visible and Infrared Mapping Spectrometers

A focal plane assembly combining hybrid electronic components with passive optical components within a single hermetically sealed package has been designed by Cincinnati Electronics to meet the performance requirements imposed by the Comet Rendezvous/Asteroid Flyby (CRAF) and Cassini Visible and Infrared Mapping Spectrometers (VIMSs). A single line array of 256 InSb photodiodes, accessed by two 1 x 128 multiplexers, provides continuous spectral coverage from 0.85 to 5.1 microns. Intrinsic field-of-view apertures and a unique order sorting filter require critical optical alignment within the hybrid. FPA performance requirements, design approach, and critical issues are discussed.

Staller, Craig↗

Low noise HgCdTe 128 x 128 SWIR FPA for Hubble space telescope

Large area focal plane arrays of unprecedented performance were developed for use in Near Infrared Camera and Multi-Object Spectrometer (NICMOS), a proposed Hubble Space Telescope refurbishment instrument. These FPAs are 128x128-element, HgCdTe hybrid arrays with a cutoff wavelength of 2.5 microns. The multiplexer consists of a CMOS field effect transistor switch array with a typical mean readout noise of less than 30 electrons. The detectors typically have a mean dark current of less than 10 electrons/s at 77 K, with currents below 2 electrons measured at 60 K (both at 0.5 V reverse bias). The mean quantum efficiency is 40 to 60 percent at 77 K for 1.0 to 2.4 microns. Functional pixel yield is typically greater than 99 percent, and the power consumption is approximately 0.2 mW (during readout only).

Blessinger, Michael↗

Laboratory and telescope use of the NICMOS2 128 x 128 HgCdTe array

The second generation of Hubble Space Telescope (HST) instruments will include a near-infrared instrument. This choice has driven the development of near-infrared arrays to larger sizes and lower read noises. Rockwell International has delivered an array for use in the Near Infrared Camera and Multi-Object Spectrometer (NICMOS) instrument; this array has been dubbed NICMOS2. NICMOS2 is a 128x128 array of HgCdTe diodes In-bonded to a switched MOSFET readout. The readout was specifically designed for astronomical use with the HST requirement of low read noise a prime goal. These arrays use detector material which is similar to that used by Rockwell in previous arrays (e.g., HgCdTe produced on a sapphire substrate), but the NICMOS2 devices differ substantially from other 128x128 arrays produced by Rockwell in having a read noise of only 30 electrons when read out using appropriate correlated sampling. NICMOS2 has now been characterized in the laboratory, and it has been used on groundbased telescopes.

Rieke, Marcia J.↗

Future directions for NICMOS arrays

The Near Infrared Camera and Multi-Object Spectrometer (NICMOS) for the Hubble Space Telescope (HST) requires focal plane arrays of 256x256 pixels for both its cameras and its spectrometers. The new arrays, developed by the Rockwell Corporation for NICMOS, have 40 microns pixels of HgCdTe bump bonded to a switched MOSFET readout. Expected read noise and dark current for the arrays at 60 K are 30 e and 1 e/sec. respectively. The basis for these numbers is previous experience with 128x128 arrays.

Thompson, R.↗

HgCdTe 256x256 NWIR FPA

Researchers developed a HgCdTe 256x256 focal plane array (FPA) which operates in the 1 to 5 micron band. This is presently the largest demonstrated HgCdTe FPA. The detector material is HgCdTe on sapphire (PACE-1 technology) which has a low thermal expansion mismatch with silicon. The multiplexer is a CMOS FET-switch device processed through a commercial silicon foundry. The multiplexer input is direct injection and the charge capacity is about 2 times 10 to the 7th power electrons. The kTC limited read noise is 400 electrons. Researchers demonstrated high background imaging using the device. The broadband quantum efficiency is measured to be 59 percent. Dark currents less than 0.1 pA were measured at 77 K for detectors processed on PACE-1 material with 4.9 microns cutoff. The dark currents decrease as the temperature is lowered, and researchers are presently studying the T less than 77 K characteristics. The interconnect yield is greater than 95 percent. The devices are available for astronomical applications.