Unresolved resonance parameter evaluation and uncertainty quantification of n + 181Ta reactions
Not Available
Engineering topics
Publications and source records attributed to Block, Robert C..
Not Available
A new 181 Ta neutron resolved resonance region evaluation has been performed from the thermal energy range up to approximately 2.5 keV. The R-matrix SAMMY code was used with the Reich–Moore approximation to evaluate resonance parameters from several experimental data sets. A Monte Carlo approach was used for resonance spin assignments and generating 59 small fictitious resonance levels which were shown to improve the cumulative level, Porter-Thomas, and Wigner distributions as compared to theoretical predictions. Covariance information was also generated for the entire resolved resonance region. Finally, the positive impact of the new evaluation was validated through benchmark calculations which were sensitive to the 181 Ta cross section and showed improvement in the reactivity bias for several benchmark cases.
This paper provides a template of expected uncertainties and correlations for measurements of total neutron cross-section observables by transmission. Measurements with time-of-flight and mono-energetic neutron sources are covered. The information required for evaluations in the resonance region and high energy region is detailed, along with the template of uncertainties and correlations that can be used in the absence of other information.
This paper provides a template of expected uncertainties and correlations for measurements of neutron-induced capture and charged-particle production cross sections. Measurements performed in-beam include total absorption spectroscopy, total energy detection, γ -ray spectroscopy, and direct charged-particle detection. Offline measurements include activation analysis and accelerator mass spectrometry. The information needed for proper use of the datasets in resonance region and high energy region evaluations is described, and recommended uncertainties are provided when specific values are not available for a dataset.
To resolve discrepancies in evaluated cross sections among major nuclear data libraries, energy-differential neutron transmission and radiative capture yield of 181 Ta were measured from 0.15 to 100 keV using multiple sample thicknesses. The new measurements provide resolution such that the resolved resonance region (RRR) can be evaluated up to at least 2.5 keV and the unresolved resonance region can be evaluated up to at least 100 keV. The transmission and capture yield measurements were modeled using resonance parameters from three major libraries to assess the predictive capability of each. It was found that JENDL-5.0 performed best in the RRR. Because of the poor performance of the U.S. ENDF/B evaluation, it is recommended that ENDF/B be reevaluated for 181 Ta.