Search NASA⌕ Search

Engineering topics

Blue, B. E.

Publications and source records attributed to Blue, B. E..

At least 19 records

Production of high fluence laser beams using ion wave plasma optics

Optical components for laser beams with high peak and averaged powers are being developed worldwide using stimulated plasma scattering that occurs when plasmas interact with intense, coherent light. After decades of pursuit of pulse compressors, mirrors, and other plasma based components that can be created by stimulated scattering from electron density perturbations forming on ultra-short time scales (e.g., via Stimulated Raman Scattering), more recent work has produced optical components on longer time scales allowing ion motion as well [via Stimulated Brillouin Scattering (SBS)]. In the most recent work, ion wave plasma optics have had success in producing pulses of focusable coherent light with high energy and fluence by operating on ns time scales and now promise to enable numerous applications. Experiments have further shown that in some parameter regimes, even simple plasma response models can describe the output of such optics with sufficient accuracy that they can be used as engineering tools to design plasma optics for future applications, as is already being done to control power deposition in fusion targets. In addition, the development of more sophisticated models promises to enable still higher performance from SBS driven plasma optical components under a wider range of conditions. The present status and most promising directions for future development of ion wave plasma optic techniques are discussed here.

47 OTHER INSTRUMENTATION↗

A polar direct drive liquid deuterium–tritium wetted foam target concept for inertial confinement fusion

We propose a new approach to inertial confinement fusion (ICF) that could potentially lead to ignition and propagating thermonuclear burn at the National Ignition Facility (NIF). The proposal is based upon a combination of two concepts, referred to as polar direct drive and liquid deuterium–tritium wetted foam capsules. With this new concept, 2D radiation hydrodynamic simulations indicate that ICF ignition and propagating thermonuclear burn are possible with the laser power and energy capabilities available today on the NIF.

3D printing↗

High Fluence 14 MeV Neutron Exposure Capability at the National Ignition Facility

Neutron experiments conducted at the National Ignition Facility can utilize high neutron fluences delivered in very short pulses. By adapting inertial confinement fusion laser pulses and targets, fluences above 10 15 n/cm 2 can be achieved on small experimental volumes, and prospectively up to 10 16 n/cm 2 onto capsule materials under development. Neutron pulse lengths are less than 1 ns. Large experimental volumes from 150 cm 3 to 20 L can access fluences of 10 8 -10 13 n/cm 2 . Experimental platforms may contain encapsulated hazardous materials, active electronics connected to sophisticated prompt read-out equipment, and large assemblies up to 200 kg. Furthermore, sources are designed to maximize total yield, total experimental fluence, or maximum fluenceper user-day allocated as required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High yield polar direct drive fusion neutron sources at the National Ignition Facility

Polar direct drive neutron source experiments were performed at the National Ignition Facility showing substantial improvement in total neutron yield and efficiency of conversion of laser energy to fusion output. Plastic capsules 3–4 mm in diameter were filled with 1.5 mg/cc of deuterium–tritium (DT) fuel and imploded with laser beam pointing and defocus designed to compensate for polar asymmetry introduced by the facility beam entrance angles. Radiation-hydrodynamics simulations were employed to optimize the multi-dimensional laser and target parameter space, within facility and target fabrication constraints. Ensembles of 1D simulations tuned to match the outputs of early shots in the series were used to design subsequent shots in the series. This allowed the later shots to be designed based on empirically motivated sensitivities to laser and target input parameters, while eliminating the need to explicitly model phenomena such as hydrodynamic instabilities and nonlinear laser–plasma interactions. Additionally, one experiment with a 3.0 mm diameter CH capsule produced 13.6 kJ (4.81 × 10 15 DT neutrons) from a laser input below the NIF optics damage threshold at 585 kJ, 328 TW. Two experiments with 4.0 mm capsules produced 31.3 and 33.6 kJ of fusion output (1.11 × 10 16 and 1.19 × 10 16 DT neutrons) with 1.10 MJ, 390 TW and 1.26 MJ, 425 TW of laser input, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

A genetic algorithm approach for reconstructing spectral content from filtered x-ray diode array spectrometers

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. Here, we present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources—where the exact details of spectral content were not thought to be crucial—we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

47 OTHER INSTRUMENTATION↗

Investigation of high X-ray conversion efficiency Kr filled gas sources at the National Ignition Facility

In this work, we report on the performance of high x-ray fluence Kr K-shell sources that are being developed for high energy density experiments. These targets are 4.1 mm in diameter 4.4 mm tall hollow epoxy tubes having a 40 μm thick wall holding 1.5 atm of Kr gas. For these shots, the National Ignition Facility laser delivered a nominally constant total energy of ≈750 kJ of 351 nm (3ω) light at the three power levels [e.g., ≈120 (low), ≈145 (medium), and ≈210 TW (high)]. The Kr K-shell (E photon = 8–20 keV) x-ray radiant intensity and radiant energy (kJ/sr) of these sources were found to increase as a function of laser power but began to plateau at the highest laser power. The Kr K-shell radiant energy increased from ≈1 kJ/sr at ≈120 TW to ≈2 kJ/sr at ≈210 TW. Radiation hydrodynamics simulations predict radiant energies to be always higher than these measurements. The increase in K-shell emission is attributed to its strong dependence on the electron temperature. Electron temperature distributions were inferred from measured Heα and Lyα line emission through the use of a genetic algorithm and Scram modeling. The inferred temperatures from the experiment are 20% to 30% higher than those predicted from modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A plasma amplifier to combine multiple beams at NIF

Combining laser beams in a plasma is enabled by seeded stimulated Brillouin scattering which allows cross-beam energy transfer (CBET) to occur and re-distributes the energy between beams that cross with different incident angles and small differences in wavelength [Kirkwood et al. Phys. Plasmas 4, 1800 (1997)]. Indirect-drive implosions at the National Ignition Facility (NIF) [Haynam et al. Appl. Opt. 46, 3276–3303 (2007)] have controlled drive symmetry by using plasma amplifiers to transfer energy between beams [Kirkwood et al., Plasma Phys. Controlled Fusion 55, 103001 (2013); Lindl et al., Phys. Plasmas 21, 020501 (2014); and Hurricane et al. Nature 506, 343–348 (2014)]. In this work, we show that the existing models are well enough validated by experiments to allow a design of a plasma beam combiner that, once optimized, is expected to produce a pulse of light in a single beam with the energy greatly enhanced over existing sources. The scheme combines up to 61 NIF beams with 120 kJ of available energy into a single f/20 beam with a 1 ns pulse duration and a 351 nm wavelength by both resonant and off-resonance CBET. Initial experiments are also described that have already succeeded in producing a 4 kJ, 1 ns pulse in a single beam by combination of up to eight incident pump beams containing <1.1 kJ/beam, which are maintained near resonance for CBET in a plasma that is formed by 60 pre-heating beams [Kirkwood et al., Nat. Phys. 14, 80 (2018)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma-based beam combiner for very high fluence and energy

Extreme optical fluences, much beyond the damage threshold of conventional optics, are of interest for a range of high-energy-density physics applications. Nonlinear interactions of multiple beams in plasmas have the potential to produce optics that operate at much higher intensity and fluence than is possible in solids. In inertial confinement fusion experiments indirectly driven with lasers, many beams overlap in the plasma inside a hohlraum, and cross-beam energy transfer by Brillouin scattering has been employed to redistribute energy between laser beams within the target. Here in this paper, we show that in a hot, under-dense plasma the energy of many input beams can be combined into a single well-collimated beam. The emerging beam has an energy of 4 kJ (over 1 ns) that is more than triple that of any incident beam, and a fluence that is more than double. Because the optic produced is plasma, and is diffractive, it is inherently capable of generating higher fluences in a single beam than solid-state refractive or reflective optics.

42 ENGINEERING↗

X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility

Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility’s diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding reconstructed Dante spectra using high resolution spectroscopy

The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser propagation measurements in long-scale-length underdense plasmas relevant to magnetized liner inertial fusion

Here, we report experimental results and simulations showing efficient laser energy coupling into plasmas at conditions relevant to the magnetized liner inertial fusion (MagLIF) concept. In MagLIF, to limit convergence and increase the hydrodynamic stability of the implosion, the fuel must be efficiently preheated. To determine the efficiency and physics of preheating by a laser, an Ar plasma with n e / n c r i t ~ 0.04 is irradiated by a multi-ns, multi-kJ, 0.35-μm, phase-plate-smoothed laser at spot-averaged intensities ranging from 1.0 × 10 14 to 2.5 × 10 14 W / c m 2 and pulse widths from 2 to 10 ns. Time-resolved x-ray images of the laser-heated plasma are compared to two-dimensional radiation-hydrodynamic simulations that show agreement with the propagating emission front, a comparison that constrains laser energy deposition to the plasma. The experiments show that long-pulse, modest-intensity ( I = 1.5 × 10 14 W / c m 2 ) beams can efficiently couple energy ( ~ 82 % of the incident energy) to MagLIF-relevant long-length (9.5 mm) underdense plasmas. The heating efficiency we demonstrate is significantly higher than it was thought to have been achieved in early integrated MagLIF experiments [A. B. Sefkow et al., Phys. Plasmas 21, 072711 (2014)].

42 ENGINEERING↗

Simulation study of enhancing laser driven multi-keV line-radiation through application of external magnetic fields

Here, we present a path forward for enhancing laser driven, multi-keV line-radiation from mid- to high-Z, sub-quarter-critical density, non-equilibrium plasmas through inhibited thermal transport in the presence of an externally generated magnetic field. Preliminary simulations with Kr and Ag suggest that as much as 50%–100% increases in peak electron temperatures are possible—without any changes in laser drive conditions—with magnetized interactions. The increase in temperature results in ~2–3× enhancements in laser-to-x-ray conversion efficiency for K-shell emission with simultaneous ≲4× reduction in L-shell emission using current field generation capabilities on the Omega laser and near-term capabilities on the National Ignition Facility laser. Increased plasma temperatures and enhanced K-shell emission are observed to come at the cost of degraded volumetric heating. Such enhancements in high-photon-energy x-ray sources could expand the existing laser platforms for increasingly penetrating x-ray radiography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing off-Hugoniot states in Ta, Cu, and Al to 1000 GPa compression with magnetically driven liner implosions

We report on a new technique for obtaining off-Hugoniot pressure vs. density data for solid metals compressed to extreme pressure by a magnetically driven liner implosion on the Z-machine (Z) at Sandia National Laboratories. In our experiments, the liner comprises inner and outer metal tubes. The inner tube is composed of a sample material (e.g., Ta and Cu) whose compressed state is to be inferred. The outer tube is composed of Al and serves as the current carrying cathode. Another aluminum liner at much larger radius serves as the anode. A shaped current pulse quasi-isentropically compresses the sample as it implodes. The iterative method used to infer pressure vs. density requires two velocity measurements. Photonic Doppler velocimetry probes measure the implosion velocity of the free (inner) surface of the sample material and the explosion velocity of the anode free (outer) surface. These two velocities are used in conjunction with magnetohydrodynamic simulation and mathematical optimization to obtain the current driving the liner implosion, and to infer pressure and density in the sample through maximum compression. This new equation of state calibration technique is illustrated using a simulated experiment with a Cu sample. Monte Carlo uncertainty quantification of synthetic data establishes convergence criteria for experiments. Results are presented from experiments with Al/Ta, Al/Cu, and Al liners. Symmetric liner implosion with quasi-isentropic compression to peak pressure ∼1000 GPa is achieved in all cases. These experiments exhibit unexpectedly softer behavior above 200 GPa, which we conjecture is related to differences in the actual and modeled properties of aluminum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗