Extraction of Mercury Utilizing 3D Printed Media - Mercury Extraction Coalescer (MEC) (Revision 1)

The presence of mercury in environmental or industrial settings presents a number of issues from bio-accumulation to production of toxic by-products. The primary objective of this project was the development of a 3D printed component designed to act as a coalescing filter for the removal or segregation of elemental mercury from aqueous streams. The use of 3D printing allows for the design and integration of surface microstructures and internal geometries that could be difficult if not impossible to achieve through traditional manufacturing techniques. The initial phase of testing focused on the integration of 3D printed components into both environmental remediation testing (university subcontracted testing) and simulations of high-level nuclear waste processing (SRNL). Structures ranged from simple torturous paths that provided regions where the elemental mercury could settle out of the recirculation process to micro-structured frits that have increased surface area for aid in droplet coalescence and surface adsorption.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction of Mercury Utilizing 3D Printed Media - Mercury Extraction Coalescer (MEC)

Mercury is a persistent environmental hazard that is strictly regulated. The design of a 3D printed coalescer was proposed to facilitate segregation and/or adsorption of elemental mercury from aqueous solutions. 3D printing techniques were employed to generate designed surfaces and internal geometries that would otherwise be very difficult to near impossible through traditional manufacturing processes. The proposed coalescer was designed to take advantage of advancements in 3D printing to incorporate surface sub-structures and material compositions targeted specifically at mercury adsorption. The initial phase of research targeted the design of physical structures that could assist with adsorption or segregation of mercury from acidic condensate, rendering it isolated and preventing recirculation back into the chemical process, as well as implementation into standard environmental remediation techniques for contaminated aqueous solutions. Future work was to focus on formulating reactive coalescers to improve chemisorption along with physisorption.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-faced GRAYQB™: a radiation mapping device

GrayQb{trademark} is a novel technology that has the potential to characterize radioactively contaminated areas such as hot cells, gloveboxes, small and large rooms, hallways, and waste tanks. The goal of GrayQb{trademark} is to speed the process of decontaminating these areas, which reduces worker exposures and promotes ALARA considerations. The device employs Phosphorous Storage Plate (PSP) technology as its primary detector material. PSPs, commonly used for medical applications and non-destructive testing, can be read using a commercially available scanner. The goal of GrayQb{trademark} technology is to locate, quantify, and identify the sources of contamination. The purpose of the work documented in this report was to better characterize the performance of GrayQb{trademark} in its ability to present overlay images of the PSP image and the associated visual image of the location being surveyed. The results presented in this report are overlay images identifying the location of hot spots in both controlled and field environments. The GrayQb{trademark} technology has been mainly tested in a controlled environment with known distances and source characteristics such as specific known radionuclides, dose rates, and strength. The original concept for the GrayQb{trademark} device involved utilizing the six faces of a cube configuration and was designed to be positioned in the center of a contaminated area for 3D mapping. A smaller single-faced GrayQb{trademark}, dubbed GrayQb SF, was designed for the purpose of conducting the characterization testing documented in this report. This lighter 2D version is ideal for applications where entry ports are too small for a deployment of the original GrayQb™ version or where only a single surface is of interest. The shape, size, and weight of these two designs have been carefully modeled to account for most limitations encountered in hot cells, gloveboxes, and contaminated areas. GrayQb{trademark} and GrayQb{trademark} SF share the same fundamental detection system design (e.g., pinhole and PSPs). Therefore, performance tests completed on the single face GrayQB in this report is also applicable to the six- faced GrayQB (e.g., ambient light sensitivity and PSP response). This report details the characterization of the GrayQb{trademark} SF in both an uncontrolled environment; specifically, the Savannah River Site (SRS) Plutonium Fuel Form Facility in Building 235-F (Metallurgical Building) and controlled testing at SRS’s Health Physics Instrument Calibration Facility and SRS’s R&D Engineering Imaging and Radiation Systems Building. In this report, the resulting images from the Calibration Facility were obtained by overlaying the PSP and visual images manually using ImageJ. The resulting images from the Building 235-F tests presented in this report were produced using ImageJ and applying response trends developed from controlled testing results. The GrayQb{trademark} technology has been developed in two main stages at Savannah River National Laboratory (SRNL): 1) the GrayQb{trademark} development was supported by SRNL’s Laboratory Directed Research and Development Program and 2) the GrayQb{trademark} SF development and its testing in Building 235-F were supported by the Office of Deactivation and Decommissioning and Facility Engineering (EM-13), U.S. Department of Energy – Office of Environmental Management.