Search NASA⌕ Search

Engineering topics

Bocci, V.

Publications and source records attributed to Bocci, V..

At least 19 records

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

DarkSide-20k sensitivity to light dark matter particles

The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV c$^{−2}$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV c$^{−2}$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP–nucleon interaction cross-sections below 1 × 10$^{−42}$ cm$^{2}$ is achievable for WIMP masses above 800 MeV c$^{−2}$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV c$^{−2}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for dark matter annual modulation with DarkSide-50

Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eV ee , the lowest threshold ever achieved in such a search. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.

Dark Matter detectors (WIMPs, axions, etc.)↗

Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils produced in a target material from the WIMP elastic scattering. The experimental identification of the direction of the WIMP-induced nuclear recoils is a crucial asset in this field, as it enables unmistakable modulation signatures for dark matter. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity in argon dual-phase time projection chambers (TPC), that are widely considered for current and future direct dark matter searches. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud. Data were taken with nuclear recoils of known directions and kinetic energy of 72 keV, which is within the range of interest for WIMP-induced signals in argon. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is $R < 1.072$ with 90 % confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: ${}^{36}\hbox {Ar}$, ${}^{38}\textrm{Ar}$, and ${}^{40}\textrm{Ar}$. We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

Abstract We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for 25 rare and forbidden decays of D + and ${D}_s^{+}$ mesons

A search is performed for rare and forbidden charm decays of the form ${D}_{(s)}^{+}\to {h}^{\pm }{\mathrm{\ell}}^{+}{\mathrm{\ell}}^{\left(\prime \right)\mp } $, where h ± is a pion or kaon and ℓ (')± is an electron or muon. The measurements are performed using proton-proton collision data, corresponding to an integrated luminosity of 1.6 fb –1 , collected by the LHCb experiment in 2016. No evidence is observed for the 25 decay modes that are investigated and 90 % confidence level limits on the branching fractions are set between 1.4 × 10 –8 and 6.4 × 10 –6 . In most cases, these results represent an improvement on existing limits by one to two orders of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy neutral leptons in $W^+\rightarrow \mu ^{+}\mu ^{\pm }\, \text {jet}$ decays

A search is performed for heavy neutrinos in the decay of a W boson into two muons and a jet. The data set corresponds to an integrated luminosity of approximately 3.0fb –1 of proton–proton collision data at centre-of-mass energies of 7 and 8 TeV collected with the LHCb experiment. Both same-sign and opposite-sign muons in the final state are considered. Data are found to be consistent with the expected background. Upper limits on the coupling of a heavy neutrino with the Standard Model neutrino are set at 95% confidence level in the heavy-neutrino mass range from 5 to 50GeV/c 2 . These are of the order of 10 –3 for lepton-number-conserving decays and of the order of 10 –4 for lepton-number-violating heavy-neutrino decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the CKM angle γ in B ± → DK ± and B ± → Dπ ± decays with D → $ {K}_{\mathrm{S}}^0 $h + h -

A measurement of CP -violating observables is performed using the decays B ± → DK ± and B ± → Dπ ± , where the D meson is reconstructed in one of the self-conjugate three-body final states \( {K}_{\mathrm{S}}^0 \) π + π - and \( {K}_{\mathrm{S}}^0 \) K + K - (commonly denoted \( {K}_{\mathrm{S}}^0 \) h + h - ). The decays are analysed in bins of the D -decay phase space, leading to a measurement that is independent of the modelling of the D -decay amplitude. The observables are inter- preted in terms of the CKM angle γ . Using a data sample corresponding to an integrated luminosity of 9 fb - 1 collected in proton-proton collisions at centre-of mass energies of 7, 8, and 13 TeV with the LHCb experiment, γ is measured to be \( \left({68.7}_{-5.1}^{+5.2}\right){}^{\circ} \) . The hadronic parameters \( {r}_B^{D K},{r}_B^{D\pi},{\delta}_B^{D K},\kern0.5em \mathrm{and}\kern0.5em {\delta}_B^{D\pi} \) , which are the ratios and strong-phase differences of the suppressed and favoured B ± decays, are also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of differential $ b\overline{b} $- and $ c\overline{c} $-dijet cross-sections in the forward region of pp collisions at $ \sqrt{s} $ = 13 TeV

The inclusive \( b\overline{b} \) - and \( c\overline{c} \) -dijet production cross-sections in the forward region of pp collisions are measured using a data sample collected with the LHCb detector at a centre-of-mass energy of 13 TeV in 2016. The data sample corresponds to an integrated luminosity of 1.6 fb - 1 . Differential cross-sections are measured as a function of the transverse momentum and of the pseudorapidity of the leading jet, of the rapidity difference between the jets, and of the dijet invariant mass. A fiducial region for the measurement is defined by requiring that the two jets originating from the two b or c quarks are emitted with transverse momentum greater than 20 GeV/ c , pseudorapidity in the range 2 . 2 < η < 4 . 2, and with a difference in the azimuthal angle between the two jets greater than 1.5. The integrated \( b\overline{b} \) -dijet cross-section is measured to be 53 . 0 ± 9 . 7 nb, and the total \( c\overline{c} \) -dijet cross-section is measured to be 73 ± 16 nb. The ratio between \( c\overline{c} \) - and \( b\overline{b} \) -dijet cross-sections is also measured and found to be 1 . 37 ± 0 . 27. The results are in agreement with theoretical predictions at next-to-leading order.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strong constraints on the b → sγ photon polarisation from B0 → K*0e+e-decays

An angular analysis of the B 0 → K* 0 e + e - decay is performed using a data sample corresponding to an integrated luminosity of 9 fb - 1 of pp collisions collected with the LHCb experiment. The analysis is conducted in the very low dielectron mass squared ( q 2 ) interval between 0 . 0008 and 0 . 257 GeV 2 , where the rate is dominated by the B 0 → K * 0 γ transition with a virtual photon. The fraction of longitudinal polarisation of the K * 0 meson, F L , is measured to be F L = (4 . 4 ± 2 . 6 ± 1 . 4)%, where the first uncertainty is statistical and the second systematic. The \( {A}_{\mathrm{T}}^{\mathrm{Re}} \) observable, which is related to the lepton forward-backward asymmetry, is measured to be \( {A}_{\mathrm{T}}^{\mathrm{Re}} \) = - 0 . 06 ± 0 . 08 ± 0 . 02. The \( {A}_{\mathrm{T}}^{(2)} \) and \( {A}_{\mathrm{T}}^{\mathrm{Im}} \) transverse asymmetries, which are sensitive to the virtual photon polarisation, are found to be \( {A}_{\mathrm{T}}^{(2)} \) = 0 . 11 ± 0 . 10 ± 0 . 02 and \( {A}_{\mathrm{T}}^{\mathrm{Im}} \) = 0 . 02 ± 0 . 10 ± 0 . 01. The results are consistent with Standard Model predictions and provide the world’s best constraint on the b → sγ photon polarisation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗