Search NASA⌕ Search

Engineering topics

Bock, F.

Publications and source records attributed to Bock, F..

2025 EIC-France Workshop: Physics Highlights and Perspectives

This document presents a synthesis of the theory contributions and discussions from the 2nd EIC-France Workshop, held at IJCLab (Orsay) on 1-3 December 2025. The workshop brought together members of the French hadron-physics community to review recent theoretical developments relevant to the future Electron-Ion Collider (EIC) and to coordinate national efforts in preparation for its early physics program. The report first summarizes the collider's initial running conditions and luminosity performance, as outlined in the EIC Early Science Matrix. It then provides concise overviews of the theoretical presentations on inclusive, semi-inclusive, exclusive, heavy-flavor, and small-x physics. Based on these discussions, two measurements emerged as especially well suited for early EIC operation and strongly aligned with areas of established French expertise: inclusive diffraction and inclusive quarkonium production. These channels offer clean signatures, robust theoretical interpretability, and direct sensitivity to fundamental QCD phenomena such as gluon saturation, heavy-quark dynamics, and the small-x structure of hadrons and nuclei. In addition, the workshop identified longer-term physics opportunities that will benefit from the full capabilities of the EIC after its ramp-up phase. These include accessing the three-dimensional structure of the pion through the Sullivan process and a broader program of exclusive three-body final states, both of which represent high-impact avenues for exploring hadronic structure and non-perturbative QCD. Together, the elements summarized in this report provide a coherent overview of the strategic priorities and scientific ambitions shaping the French community's contribution to the EIC physics program.

FOS: Physical sciences↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for e → τ charged lepton flavor violation at the EIC with the ECCE detector

The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ μ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e → τ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the τ-leptons created in the DIS process ep → τX are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong τ-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e → τ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in τ identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hot QCD White Paper

Hot QCD physics studies the nuclear strong force under extreme temperature and densities. Experimentally these conditions are achieved via high-energy collisions of heavy ions at the Relativistic Heavy Ion Collider (RHIC) and the Large Hadron Collider (LHC). In the past decade, a unique and substantial suite of data was collected at RHIC and the LHC, probing hydrodynamics at the nucleon scale, the temperature dependence of the transport properties of quark-gluon plasma, the phase diagram of nuclear matter, the interaction of quarks and gluons at different scales and much more. This document, as part of the 2023 nuclear science long range planning process, was written to review the progress in hot QCD since the 2015 Long Range Plan for Nuclear Science, as well as highlight the realization of previous recommendations, and present opportunities for the next decade, building on the accomplishments and investments made in theoretical developments and the construction of new detectors. Furthermore, this document provides additional context to support the recommendations voted on at the Joint Hot and Cold QCD Town Hall Meeting, which are reported in a separate document.

FOS: Physical sciences↗

Exclusive J/$\psi$ detection and physics with ECCE

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been recommended as a reference design for the proposed Electron-Ion Collider (EIC) program. Here, this paper presents simulation studies of exclusive J/$\psi$ detection and selected physics impact results in EIC using the projected ECCE detector concept. Exclusive quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. Preliminary results estimate the excellent statistics benefited from the large cross section of J/$\psi$ photoproduction and superior performance of ECCE detector concept. The precise measurement of exclusive J/$\psi$ photoproduction at EIC will help us to more deeply understand nuclear gluon distributions, near threshold production mechanism and nucleon mass structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scientific computing plan for the ECCE detector at the Electron Ion Collider

The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. Here, in this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal Filtering Using Principal Component Analysis and Karhunen-Loeve Expansion Approaches for Regional GPS Network Analysis

Spatial filtering is an effective way to improve the precision of coordinate time series for regional GPS networks by reducing so-called common mode errors, thereby providing better resolution for detecting weak or transient deformation signals. The commonly used approach to regional filtering assumes that the common mode error is spatially uniform, which is a good approximation for networks of hundreds of kilometers extent, but breaks down as the spatial extent increases. A more rigorous approach should remove the assumption of spatially uniform distribution and let the data themselves reveal the spatial distribution of the common mode error. The principal component analysis (PCA) and the Karhunen-Loeve expansion (KLE) both decompose network time series into a set of temporally varying modes and their spatial responses. Therefore they provide a mathematical framework to perform spatiotemporal filtering.We apply the combination of PCA and KLE to daily station coordinate time series of the Southern California Integrated GPS Network (SCIGN) for the period 2000 to 2004. We demonstrate that spatially and temporally correlated common mode errors are the dominant error source in daily GPS solutions. The spatial characteristics of the common mode errors are close to uniform for all east, north, and vertical components, which implies a very long wavelength source for the common mode errors, compared to the spatial extent of the GPS network in southern California. Furthermore, the common mode errors exhibit temporally nonrandom patterns.

displacement↗