Search NASA⌕ Search

Engineering topics

Boclet, D.

Publications and source records attributed to Boclet, D..

Observation of gamma ray low state of Cygnus X-1

Cygnus X-1 was observed on 25 Sep. 1980 with a high-resolution cooled germanium spectrometer in the Low Energy Gamma-Ray Spectrometer (LEGS) balloon-borne experiment. The source was in a very low gamma-ray state: the differential flux at 45 keV was 1.3 x 10 exp -3 ph/sq cm sec keV. The results of a power low fit to our data are compared with three other observations of a similar state. All of these spectra represent significantly lower gamma-ray fluxes than normally observed in the x-ray low or high state. Only HEAO-3 has simultaneous x-ray data and, for that case, Cygnus X-1 was in the x-ray low state which normally corresponds to the highest gamma-ray emission. The similarity of the gamma-ray spectra suggest that all these measurements may correspond to the unusual state observed by HEAO-3.

Tueller, T.↗

Evidence for variability of the hard X-ray feature in the Hercules X-1 energy spectrum

The hard X-ray spectrum of HER X-1 was measured for the first time with a high resolution (1.4 keV FWHM) germanium spectrometer. The observation was performed near the peak of the on-state in the 35 day cycle and the 1.24 pulsations were observed between the energies of 20 keV and 70 keV. The feature corresponds to an excess of 7.5 sigma over the low energy continuum. Smooth continuum models are poor fits to the entire energy range (chance probabilities of 2 percent or less). The best fit energies are 35 keV for an absorption line and 39 keV for an emission line. These are significantly lower energies than those derived from previous experiments. A direct comparison of the data with the results of the MPI/AIT group shows statistically significant variations which strongly suggest variability in the source. Previously announced in STAR as N83-37036

Tueller, J.↗

Evidence for variability of the hard X-ray feature in the Hercules X-1 energy spectrum

The hard X-ray spectrum of HER X-1 was measured for the first time with a high resolution (1.4 keV FWHM) germanium spectrometer. The observation was performed near the peak of the on-state in the 35 day cycle and the 1.24 pulsations were observed between the energies of 20 keV and 70 keV. The feature corresponds to an excess of 7.5 sigma over the low energy continuum. Smooth continuum models are poor fits to the entire energy range (chance probabilities of 2 percent or less). The best fit energies are 35 keV for an absorption line and 39 keV for an emission line. These are significantly lower energies than those derived from previous experiments. A direct comparison of our data with the results of the MPI/AIT group shows statistically significant variations which strongly suggest variability in the source.

Tueller, J.↗

A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

Paciesas, W. S.↗

A high energy resolution experiment in the hard X-ray range

The Low Energy Gamma-Ray Spectrometer (LEGS), a joint project among NASA/GSFC, CEN-SACLAY, and Rice University, is designed to perform fine energy resolution measurements of astrophysical sources. In its low energy configuration (20-800 keV energy range) the instrument uses three planar detectors (effective area of 53 sq cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (FOW of about 5 x 10 deg FWHM). In a typical one-day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is not greater than about 0.0003 ph/sq cm s (at 100 kev).

Paciesas, W.↗

High energy resolution observation of the Crab and AO535 plus 26 in the hard X-ray range

A number of uncertainties exist currently regarding the existence of gamma-ray lines in the Crab spectrum. An investigation was, therefore, conducted, and the Crab was observed for eight hours during a balloon flight from Palestine, TX, on September 26, 1980. It appeared that the binary source AO535 plus 26 contaminated the Crab data. It was, however, possible to separate the two sources. The obtained results are discussed and evaluated. It is found that the possibility of a line at 73 keV with the intensity reported by Ling et al. (1979) can be excluded for the obtained data. The 400 keV line cannot be ruled out. The results concerning AO535 plus 26 are very different from those previously obtained.

Hameury, J. M.↗

Confidence about line features in Her X-1 spectrum

A balloon borne X-ray telescope was flown Aire-surl'Adour, France to search for pulsation of the X-ray source HER X1. The source was measured for about 3500 s relative exposure larger than 0.75 and features were detected at 57.5 plus or minus 7.5 keV and 135 plus or minus 10 keV in the spectrum. Data were reanalyzed in terms of possibility of gain shift encoder. The very strong dependence of the line features on such a shift is discussed.

Durouchoux, P.↗