Search NASA⌕ Search

Engineering topics

Bogard, James S

Publications and source records attributed to Bogard, James S.

Design and Performance Considerations for the Quantitative Measurement of HEU Residues Resulting from 99Mo Production

Molybdenum-99 is produced by the irradiation of high-enriched uranium (HEU) resulting in the accumulation of large quantities of HEU residues. In general, these residues are not recycled but are either disposed of or stored in containers with surface exposure rates as high as 100 R/h. The 235U content of these waste containers must be quantified for both accountability and waste disposal purposes. The challenges of quantifying such difficult-to-assay materials are discussed, along with performance estimates for each of several potential assay options. In particular, the design and performance of a High Activity Active Well Coincidence Counting (HA-AWCC) system designed and built specifically for these irradiated HEU waste materials are presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combining Measurements with Three-Dimensional Laser Scanning System and Coded Aperture Gamma-Ray Imaging Systems for International Safeguards Applications

Being able to verify the operator's declaration in regards to technical design of nuclear facilities is an important aspect of every safeguards approach. In addition to visual observation, it is relevant to know if nuclear material is present or has been present in piping and ducts not declared. The possibility of combining different measurement techniques into one tool should optimize the inspection effort and increase safeguards effectiveness. Oak Ridge National Laboratory (ORNL) is engaged in a technical collaboration project involving two U.S. Department of Energy foreign partners to investigate combining measurements from a three-dimensional (3D) laser scanning system and gamma-ray imaging systems. ORNL conducted simultaneous measurements with a coded-aperture gamma-ray imager and the 3D laser scanner in an operational facility with complex configuration and different enrichment levels and quantities of uranium. This paper describes these measurements and their results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combining Measurements with Three-Dimensional Laser Scanning System and Coded Aperture Gamma-Ray Imaging System for International Safeguards Applications

Being able to verify the operator's declaration in regard to the technical design of nuclear facilities is an important aspect of every safeguards approach. In addition to visual observation, it is necessary to know if nuclear material is present or has been present in undeclared piping and ducts. The possibility of combining the results from different measurement techniques into one easily interpreted product should optimize the inspection effort and increase safeguards effectiveness. A collaborative effort to investigate the possibility of combining measurements from a three-dimensional (3D) laser scanning system and gamma-ray imaging systems is under way. The feasibility of the concept has been previously proven with different laboratory prototypes of gamma-ray imaging systems. Recently, simultaneous measurements were conducted with a new highly portable, mechanically cooled, High Purity Germanium (HPGe), coded-aperture gamma-ray imager and a 3D laser scanner in an operational facility with complex configuration and different enrichment levels and quantities of uranium. With specially designed software, data from both instruments were combined and a 3D model of the facility was generated that also identified locations of radioactive sources. This paper provides an overview of the technology, describes the measurements, discusses the various safeguards scenarios addressed, and presents results of experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the person s blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metaland solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ANISOTROPY FACTORS FOR A 252Cf SOURCE

A new 252Cf source has been procured for use at the Dosimetry Applications and Research (DOSAR) facility at the Oak Ridge National Laboratory (ORNL). This source was encapsulated by the Californium Facility at ORNL, however, the encapsulation differs from previous designs designated as SR-Cf-100. The new encapsulation, designated SR-Cf-3000, has a similar cylindrical radius to the previous generation, but is 1.6 cm longer. Since the encapsulation geometries differ the amount of internal scattering of neutrons will also differ leading to changes in anisotropy factors between the two designs. Additionally, the different encapsulations will affect the absorbed dose and dose equivalent delivered per neutron emitted by the source since both the quantity and energy distribution of the emitted neutrons will vary with irradiation angle. This work presents the fluence anisotropy factors for the SR-Cf-3000 series encapsulation as well as absorbed dose and dose equivalent values calculated for various angles of irradiation. The fluence anisotropy factors vary from a maximum of 1.037 to a minimum of 0.641 for irradiation angles perpendicular and parallel to the source axis, respectively. Anisotropy in absorbed dose varied from a maximum of 1.033 to a minimum of 0.676 while anisotropy of dose equivalent varied from 1.035 to 0.657.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗