Heat Pipe Precools and Reheats Dehumidified Air

Precooling and reheating by heat pipe reduces operating costs of air-conditioning. Warm air returned from air-conditioned space and cooled air supplied are precooled and reheated, respectively, by each other through a heat pipe. Heat-pipe technology brought to bear on problem of conserving airconditioning energy in hot, humid environments. Any increase in the cost of equipment due to installation of heat-pipe heat exchangers expected to be recovered in energy savings during service period of 2 years or less.

Koning, R. C.↗

Moonport to Spaceport - The changing face at KSC

The facilities and planned operations of the Orbiter Processing Facility (OPF) at Kennedy Space Center are described, noting an eventual goal of five to six weeks turnaround for the vehicle. The dual-bay OPF is being developed to handle processing of two Orbiters in parallel. Once in the facility, all fuels are drained, parts and systems needing maintenance are removed for shipping and refurbishing or repair in-place, hazardous cargo is secured, and a thorough visual inspection is made of all accessible areas. Mobile launch platforms previously used as transports in the Apollo program have been upgraded and modernized and serve for the Shuttle launch preparations. Details of launch procedures are outlined, and the reduction of launch personnel to 45 persons is mentioned. Finally, details of payload insertion and mating with the Spacelab modules are described, along with the progress on the test flights.

Boggs, W. H.↗

Identification of cost effective energy conservation measures

In addition to a successful program of readily implemented conservation actions for reducing building energy consumption at Kennedy Space Center, recent detailed analyses have identified further substantial savings for buildings representative of technical facilities designed when energy costs were low. The techniques employed for determination of these energy savings consisted of facility configuration analysis, power and lighting measurements, detailed computer simulations and simulation verifications. Use of these methods resulted in identification of projected energy savings as large as $330,000 a year (approximately two year break-even period) in a single building. Application of these techniques to other commercial buildings is discussed

Bierenbaum, H. S.↗

Autoignition - A liquid propellant explosive potential limiting phenomena

It has been thought that the unplanned mixing of the propellants of liquid launch vehicles could result in massive explosion and destruction. This paper presents results of NASA's attempt to develop a precise analytical theory and predictive model for liquid propellant explosives. Prediction model experiments involving a 'seven-chart' approach showing the relationship between yield function, mixing function, time dependence, chemical and physical reactant properties and quantity effects were used to establish a theory that autoignition takes place when propellants mix in a certain 'critical mass' or greater. An analytical confirmation of the theory has been carried out, with particular reference to possible autoignition in LOX/LH2 and LOX/RP-1 and Saturn V: it was confirmed that autoignition occurs and prevents the mixing of more than the 'critical mass' and therefore limits the explosive yield to several thousand pounds, which will disperse the remaining propellant and prohibit detonation of the total quantities otherwise suspected.

Boggs, W. H.↗