Search NASA⌕ Search

Engineering topics

Bolotnikov, A.

Publications and source records attributed to Bolotnikov, A..

At least 19 records

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-𝛽 decay detector (∼5 metric ton, 90% 136 Xe, 10% 134 Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overcoming photobleaching in imaging of single barium atoms in a solid xenon matrix

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is 136 Xe, which would double beta decay into 136 Ba. Detecting the single 136 Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical and photoelectric properties of surface barrier diodes based on n- Hg3In2Te6 crystals

The high radiation resistance of Hg3In2Te6 (MIT) single crystals to large doses of ionizing radiation makes devices quite attractive. Such a feature of the crystal structure has not only important advantages, but also causes serious technological difficulties in doping and controlling the specific resistance within the required limits and type of conductivity of single crystals. These technological difficulties create serious problems when creating structures with a potential barrier, especially with a p-n junction. At the moment, there are no publications on the creation of a p-n junction based on MIT. The only alternative is to create a potential barrier such as a Schottky diode or a metal-dielectric-semiconductor structure. This limits the use of MIT to produce, for example, rectifier diodes that can operate at relatively high reverse bias voltages. The typical resistivity of single crystals of MIT of n-type conductivity, which are used for the manufacture of diodes and photodiodes, is approximately equal to ρ≈103-104 Ω×cm. Such a specific resistance leads to a relatively large resistance of the neutral part of the single crystal, which in turn limits the direct currents of the rectifier diodes and significantly limits an important parameter of photodiodes - the dynamic range of the watt-ampere characteristic. This problem arises from the relatively high series resistance of the substrate. For rectifier diodes, this relatively large series resistance leads to a significant forward bias voltage drop, which reduces both the rectification factor and the amount of rectified current. We have already created diodes and photodiodes on Cr/MIT/Cr single crystals with a specific resistance of ρ≈103-104 Ω×cm. The diodes had relatively small dark currents but had the disadvantage of a relatively large specific resistance of the substrate, which we have already discussed above [1,2,3].

Sklyarchuk, V.↗

Study of electro-physical properties of CsPbBr3 perovskite single crystals

Methods have been developed for the synthesis and growth of lead halide perovskites CsPbBr3, which can be used as detectors of optical, X-ray and gamma-radiation. Single crystals of these compounds were grown by the Bridgman method. The melt temperature was 580 °C, the gradient at the crystallization front was 5 K/cm, and the ampoule lowering speed was 3 mm/hour. In this work, the electro-physical properties of the inorganic perovskite CsPbBr3 were investigated. Crystals for research were cut from the beginning and end of the ingot. The optical absorption spectra were measured depending on the crystal thickness and temperature, the differential resistivity dif and the product  were determined from the I-V characteristics. It was established that dif practically does not change for samples made from the beginning and the end of the ingot, and is dif  21010 Ωcm at 100 V and 293 K.

Sklyarchuk, V.↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. Furthermore, this paper describes this database application, explains how it functions, and discusses how it streamlines the design of the experiment.

47 OTHER INSTRUMENTATION↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Radiation effects induced by the energetic protons in 8x8x32 mm3 CdZnTe detectors

We report CdZnTe (CZT) detectors have been used in the past and are being actively considered for future gamma-ray space telescopes. One of the challenges of operating CZT detectors in low Earth orbit is radiation damage caused by energetic protons. Previous studies concluded that fluences of 10 8 -10 9 p/cm 2 are sufficient to cause shifting of peak positions and degradations of energy resolution. Degradation of detectors after proton irradiation has been extensively investigated to determine their radiation resistance limits and performance recovering procedures for their applications in space and nuclear nonproliferation. Here we present the study of radiation effects induced by 100 MeV protons in 3-cm long CdZnTe detectors that we recently proposed for the gamma-ray telescope GECCO. The goal this study is to evaluate the feasibility of using such long CZT detectors in future space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the Electric Field Strength on the Energy Resolution of Cr/CdTe/Pt Detectors

The electrical and spectrometric characteristics of the Cr/cadmium telluride (CdTe)/Pt structure with a metal-semiconductor type rectifying contact, used in X/γ-ray detectors, are investigated. For the detectors fabrication, chlorine-doped CdTe crystals with a resistivity of (3-6) × 10 9 Ω cm at 293 K were used. 137Cs spectra and their modification by applied voltage change were obtained. The reverse bias voltage corresponding to the best energy resolution of the Cr/CdTe/Pt structure is experimentally determined. The concentration of impurities N in the crystal, which determines the thickness of the space-charge region, is estimated. Finally, an energy resolution deterioration of the Cr/CdTe/Pt structure with increasing voltage is explained due to the Gunn effect.

47 OTHER INSTRUMENTATION↗

High-Energy 3D Calorimeter for Use in Gamma-Ray Astronomy Based on Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors

We will present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frisch-grid CdZnTe (hereafter CZT) detectors. This calorimeter aims to measure photons with energies from approximately 100 keV to 20 - 50 MeV . The expected energy resolution at 662 keV is better than 1% FWHM, and the photon interaction position-measurement accuracy is better than 1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section from 5 x 5 to 7 x 7 mm2 and length of 2 - 4 cm. The bars are arranged in modules of 4 x 4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., greater than 1 cm). Also, it allows us to use the standard (unselected) grade crystals, while achieving the energy resolution of the premium detectors and thus substantially reducing the cost of the instrument. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of gamma rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons (like a focal plane detector in a Compton camera). Also, it could provide suitable energy resolution to allow for spectroscopic measurements of gamma ray lines from nuclear decays.

Moiseev, A.↗

The polarization sensitivity of the liquid xenon imaging telescope

The properties and the expected performance of a liquid xenon (LXe) gamma-ray imaging telescope, optimized for the MeV energy region, are presented. The unique potential of this telescope as a Compton polarimeter is particularly emphasized. Based on Monte Carlo simulations, we show that the modulation factor is as high as 40% at 1 MeV with a detection efficiency close to 20%. These figures of merit, combined with the excellent background suppression capability of the three-dimensional position sensitive LXe detector, yield sensitivity at the 3 sigma level to polarization fractions as small as a few percent for strong sources, even in a balloon flight.

Aprile, E.↗