Search NASA⌕ Search

Engineering topics

Bolster, J.

Publications and source records attributed to Bolster, J..

Properties of Cosmic Deuterons Measured by the Alpha Magnetic Spectrometer

Precision measurements by the Alpha Magnetic Spectrometer (AMS) on the International Space Station of the deuteron (𝐷) flux are presented. The measurements are based on 21 × 10 6 𝐷 nuclei in the rigidity range from 1.9 to 21 GV collected from May 2011 to April 2021. We observe that over the entire rigidity range the 𝐷 flux exhibits nearly identical time variations with the 𝑝, 3 He, and 4 He fluxes. Above 4.5 GV, the 𝐷/ 4 He flux ratio is time independent and its rigidity dependence is well described by a single power law ∝𝑅 Δ with Δ 𝐷/ 4 He = −0.108 ± 0.005. This is in contrast with the 3 He/ 4 He flux ratio for which we find Δ 3 He/ 4 He = −0.289 ± 0.003. Above ∼13 GV we find a nearly identical rigidity dependence of the 𝐷 and 𝑝 fluxes with a 𝐷/𝑝 flux ratio of 0.027 ± 0.001. These unexpected observations indicate that cosmic deuterons have a sizable primarylike component. With a method independent of cosmic ray propagation, we obtain the primary component of the 𝐷 flux equal to 9.4 ± 0.5% of the 4 He flux and the secondary component of the 𝐷 flux equal to 58 ± 5% of the 3 He flux.

cosmic ray acceleration↗

Temporal Structures in Positron Spectra and Charge-Sign Effects in Galactic Cosmic Rays

We present the precision measurements of 11 years of daily cosmic positron fluxes in the rigidity range from 1.00 to 41.9 GV based on 3.4 × 10 6 positrons collected with the Alpha Magnetic Spectrometer (AMS) aboard the International Space Station. The positron fluxes show distinctly different time variations from the electron fluxes at short and long timescales. A hysteresis between the electron fluxes and the positron fluxes is observed with a significance greater than 5⁢𝜎 at rigidities below 8.5 GV. On the contrary, the positron fluxes and the proton fluxes show similar time variation. Remarkably, we found that positron fluxes are modulated more than proton fluxes with a significance greater than 5⁢𝜎 for rigidities below 7 GV. These continuous daily positron fluxes, together with AMS daily electron, proton, and helium fluxes over an 11-year solar cycle, provide unique input to the understanding of both the charge-sign and mass dependencies of cosmic rays in the heliosphere.

astroparticles↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗