The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

First transmission of electrons and ions through the KATRIN beamline

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium β-decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous 83m Kr was injected into the KATRIN source section, and a condensed 83m Kr source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. In conclusion, we have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the β-electron energy spectrum near the endpoint of tritium β-decay. We performed an integral energy analysis by an electro-static spectrometer (``Main Spectrometer''), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m 3 , and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the β-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. Furthermore, a system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300 °C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10 -11 mbar range. We demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current status of tritium calorimetry at TLK

Inside a tritium facility, calorimetry is an important analytical method as it is the only reference method for accountancy (it is based on the measurement of the heat generated by the radioactive decay). Presently, at Tritium Laboratory Karlsruhe (TLK), 4 calorimeters are in operation, one of isothermal type and three of inertial guidance control type (IGC). The volume of the calorimeters varies between 0.5 and 20.6 liters. About two years ago we started an extensive work to improve our calorimeters with regard to reliability and precision. We were forced to upgrade 3 of our 4 calorimeters due to the outdated interfaces and software. This work involved creating new LabView programs driving the devices, re-tuning control loops and replacing obsolete hardware components. In this paper we give a review on the current performance of our calorimeters, comparing it to recently available devices from the market and in the literature. We also show some ideas for a next generation calorimeter based on experiences with our IGC calorimeters and other devices reported in the literature. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Investigation of durability of optical coatings in highly purified tritium gas

Anti-reflection coated windows are part of Raman spectroscopy systems for tritium analytics in the KATRIN experiment and fusion-related applications. Damages of such windows were observed after three months of expo-sure to highly purified tritium gas in the LOOPINO facility. In this work, the origin of the damages was investigated, identified and eliminated. Coating samples manufactured by various physical vapor deposition methods have been tested for durability by exposure to pure tritium gas and subsequent visual inspection. Electron beam deposited coatings showed indications for damage after 17 days of tritium exposure in contrast to samples manufactured by ion assisted deposition or sputtering. An improved coating layout of the sample cell is presented for reliable long-term monitoring of tritium gas using Raman spectroscopy. (authors)

36 MATERIALS SCIENCE↗

First calibration measurements of an FTIR absorption spectroscopy system for liquid hydrogen isotopologues for the isotope separation system of fusion power plants

Fusion facilities like ITER and DEMO will circulate huge amounts of deuterium and tritium in their fuel cycle with an estimated throughput of kg per hour. One important capability of these fuel cycles is to separate the hydrogen isotopologues (H{sub 2}, D{sub 2}, T{sub 2}, HD, HT, DT). For this purpose the Isotope Separation System (ISS), using cryogenic distillation, as part of the Tritium Enrichment Test Assembly (TRENTA) is under development at Tritium Laboratory Karlsruhe. Fourier transform infrared absorption spectroscopy (FTIR) has been selected to prove its capability for online monitoring of the tritium concentration in the liquid phase at the bottom of the distillation column of the ISS. The actual research-development work is focusing on the calibration of such a system. Two major issues are the identification of appropriate absorption lines and their dependence on the isotopic concentrations and composition. For this purpose the Tritium Absorption IR spectroscopy experiment has been set up as an extension of TRENTA. For calibration a Raman spectroscopy system is used. First measurements, with equilibrated mixtures of H{sub 2}, D{sub 2} and HD demonstrate that FTIR can be used for quantitative analysis of liquid hydro-gen isotopologues and reveal a nonlinear dependence of the integrated absorbance from the D{sub 2} concentration in the second vibrational branch of D{sub 2} FTIR spectra. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High level tritiated water monitoring by Bremsstrahlung counting using a silicon drift detector

The β-ray induced X-ray spectrometry (BIXS) is a promising technique to monitor the tritium concentration in a fuel cycle of a fusion reactor. For in-situ measurements of high level tritiated water by Bremsstrahlung counting, the characteristics of a low-noise silicon drift detector (SDD) have been examined at the Tritium Laboratory Karlsruhe (TLK). In static measurements with constant sample volume and tritium concentration, the Bremsstrahlung spectra of tritiated water samples in a concentration range of 0.02 to 15 MBq/ml have been obtained. The volume has been kept constant at 5 cm{sup 3}. The observed spectra are well above the noise threshold. In addition to X-rays induced by β-rays, the spectra feature X-ray fluorescence peaks of the surrounding materials. No indications of memory effects have been observed. A linear relation between the X-ray intensity and the tritium concentration was obtained and the lower detection limit of the setup has been determined to 1 MBq ml{sup -1}, assessed by the Curie criterion. In addition, the spectra obtained experimentally could be reproduced with high agreement by Monte-Carlo simulations using the GEANT4-tool-kit. It was found that the present detection system is applicable to non-invasive measurements of high-level tritiated water and the SDD is a convenient tool to detect the low energy Bremsstrahlung X-rays. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced sensitivity of Raman spectroscopy for tritium gas analysis using a metal-lined hollow glass fiber

The precise compositional analysis of tritium-containing gases is of high interest for tritium accountancy in future fusion power plants. Raman spectroscopy provides a fast and contact-free gas analysis procedure with high precision, thus being an advantageous tool for the named purpose. In this paper, it is shown that the sensitivity achieved with conventional Raman systems (in 90 degrees or forward/backward configurations) can be enhanced by at least one order of magnitude by using a metal-lined hollow glass fiber as the Raman cell. This leads to the ability of detecting low partial pressures of tritium within short measurement intervals (< 0.5 mbar in < 0.5 s) opening the way for real-time applications.

07 ISOTOPE AND RADIATION SOURCES↗

Raman spectroscopy at the tritium laboratory Karlsruhe

Raman spectroscopy is employed successfully for analysis of hydrogen isotopologues at the Tritium Laboratory Karlsruhe (TLK). Raman spectroscopy is based on the inelastic scattering of photons off molecules. Energy is transferred to the molecules as rotational/vibrational excitation being characteristic for each type of molecule. Thus, qualitative analysis is possible from the Raman shifted light, while quantitative information can be obtained from the signal intensities. After years of research and development, the technique is now well-advanced providing fast (< 10 s), precise (< 0.1%) and true (< 3%) compositional analysis of gas mixtures of hydrogen isotopologues. In this paper, we summarize the recent achievements in the further development on this technique, and the various applications for which it is used at TLK. Raman spectroscopy has evolved as a versatile, highly accurate key method for quantitative analysis complementing the port-folio of analytic techniques at the TLK.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the neutrino mass experiment KATRIN

The most sensitive way to determine the neutrino mass scale without further assumptions is to measure the shape of a tritium beta spectrum near its kinematic end-point. Tritium is the nucleus of choice because of its low endpoint energy, superallowed decay and simple atomic structure. Within an international collaboration the Karlsruhe Tritium Neutrino experiment (KATRIN) is currently being built up at KIT. KATRIN will allow a model-independent measurement of the neutrino mass scale with an expected sensitivity of 0.2 eV/c{sup 2} (90% CL). KATRIN will use a source of ultrapure molecular tritium. This contribution presents the status of the KATRIN experiment, thereby focusing on its Calibration and Monitoring System (CMS), which is the last component being subject to research/development. After a brief overview of the KATRIN experiment in Section II the CMS is introduced in Section III. In Section IV the Beta Induced X-Ray Spectroscopy (BIXS) as method of choice to monitor the tritium activity of the KATRIN source is described and first results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tritium processing loop for KATRIN experiment

The design of tritium processing loop for KATRIN tritium source supported by high purity of tritium has been demonstrated. The demonstration has showed tritium beta spectrum using a high energy resolution electrostatic spectrometer with adiabatic magnetic collimation. The demonstration proved that the systematic uncertainties in KATRIN can cause the use of a windowless gaseous tritium source (WGTS) as the main beta source. The tritium processing system (TPS) involves an inner loop providing the circulation of tritium through WGTS and control of isotope composition of the circulating gas. The demonstration compress and purify the pumped tritium by TPS and returned back to the source. The processing capability of the system in the demonstration kept on the level of 40 gram of tritium per day. The demonstration proved that the system can fulfil the requirements of KATRIN project with stable circulation of pure tritium. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A decade of tritium technology development and operation at the tritium laboratory Karlsruhe

The Tritium Laboratory Karlsruhe (TLK) has been designed to handle relevant amounts of tritium for the development of tritium technology for fusion reactors. This paper describes the tritium technology development and experience gained during the upgrade of facilities, interventions, replacement of failed components and operation of the TLK since its commissioning with tritium in 1994. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First tritium results of the KATRIN test experiment TRAP

The TRAP experiment (Tritium Argon frost Pump) has been built at the Tritium Laboratory Karlsruhe (TLK) as a test rig for the Cryogenic Pumping Section (CPS) of the Karlsruhe Tritium Neutrino Experiment (KATRIN). TRAP employs a heterogeneous layer of pre-condensed argon to adsorb hydrogen isotopes at {approx} 4.2 K This paper presents results obtained in the first three tritium experiments with TRAP. (authors)

42 ENGINEERING↗

Determination of neutrino mass from tritium beta decay

The most sensitive way to determine the neutrino mass scale without further assumptions is to measure the shape of a tritium beta spectrum near its endpoint. Tritium is the nucleus of choice because of its low endpoint energy, super allowed decay, simple nuclear properties and simple atomic structure. Tritium beta decay experiments have been performed for more than 60 years yielding in an upper limit of the electron neutrino mass of 2 eV/c{sup 2}. The Karlsruhe Tritium Neutrino experiment (KATRIN) will improve the sensitivity on the neutrino mass by another order of magnitude. This article gives a short survey of 6 decades of tritium beta decay experiments and discusses the future steps. (authors)