Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Dynamic Model of Refrigerator with Thermal Energy Storage for Demand Flexibility

A refrigerator is an essential appliance for both commercial and residential applications. Thermal (Cold) energy storage can effectively reduce the carbon emission from refrigerators. This preliminary study investigated the demand flexibility of a domestic refrigerator using thermal (cold) energy storage through dynamic modeling and controls. The models include both fresh and frozen compartments, a vapor compression cycle loop, and thermal storage panels. Results show that thermal energy storage can effectively achieve temperature control of the compartments within the 4-hour time window. The load reduction and cost savings (46.3%) were achieved through the TES using TOU rates.

Gao, Zhiming

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Benchmark Testing of Two Residential Refrigerators Using R-600a

Household refrigerators provide a convenient and safe means of food preservation and storage. More than 100 million refrigerators are used in US homes, resulting in significant primary energy consumption and carbon emissions. As a greenhouse gas with a 100-year global warming potential of 1,430, R-134a has been banned in new US domestic refrigerators and freezers since 2021, and R-600a with a global warming potential of 3 is widely employed as a working fluid in the current US household refrigerator market. In this paper, benchmark testing was conducted for two 2023 refrigerators using R-600a. Moreover, the effect of representative customer use patterns, such as door opening and warm food storage, was studied to evaluate the effect on the energy consumption of the refrigerators. These results will provide background knowledge for facilitating the integration of new technologies to achieve significantly reduced greenhouse gas emissions in future efficient refrigerators.

Gao, Zhiming

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI