Boudreaux, Philip R.

Publications and source records attributed to Boudreaux, Philip R..

At least 19 records

High-Efficiency Thermoelectric Clothes Dryer (CRADA Final Report)

A typical clothes dryer in the US accounts for 7% of the average residential customer’s electric bill. Nationwide, consumers pay about $\$$9 billion annually for clothes drying. While energy efficiency for most household appliances has improved by a factor of 2 or more in recent decades, today’s clothes dryers perform similarly to units from the 1970s. Dryer efficiency is measured by the combined energy factor (CEF), with today’s units typically drying 3.73 lb of cloth per kWh consumed. An ENERGY STAR qualified unit must achieve 3.93 lb/kWh (for standard size electric units) and dry in less than 80 minutes. ORNL and CRADA partner Samsung Electronics America have developed an efficient prototype clothes dryer that uses thermoelectric heat pumps instead of electric resistance to dry the clothes. The prototype fabricated at ORNL successfully demonstrated in the laboratory a CEF of 6.89 lb/kWh at standard conditions of 75°F and 50% Relative Humidity (RH), exceeding the original project target of 6.0 lb/kWh. Additional trials on the same prototype achieved faster dry time with slightly lower CEF, meeting all requirements for ENERGY STAR product qualification. Deploying dryers with energy factor of 6 nationwide represents a technical potential of 234 TBtu/yr primary energy savings. The modeling and prototype development activities for the thermoelectric clothes dryer under this CRADA are summarized in this final report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Building Science Advisor: A Web-Based Tool to Assess the Durability of Building Envelope Components

The Department of Energy (DOE) and Oak Ridge National Laboratory (ORNL) have developed an innovative new design tool that will put building science expert advice in the hands of every building designer who cares to manage moisture risk in high-R envelope components. As modern buildings become increasingly more airtight, constructed with modern labor-saving materials, and equipped with air-conditioning, they have become less forgiving to moisture intrusion. The Building Science Advisor (BSA) provides building science knowledge and advice based on expert experience, field measurements, laboratory tests, and computer simulations.BSA users are prompted to enter relevant information about the building location, design, and material selection options like cladding, structural system, and insulation. Influential factors such as climate, building air tightness, material properties, and internal moisture loads are also considered to estimate and compare the moisture durability performance of several design options. If the BSA deems the assembly’s performance unsatisfactory, it will provide the reasons why, and suggest necessary changes to wall design to ensure more robust performance.Using the BSA tool enables building designers to confidently select assembly design characteristics that achieve their design goals with the least moisture durability risk. Links to design-specific guidance are also be provided to help users manage any remaining risk. This tool will further enable DOE’s Building Technologies Office (BTO) to meet its long-term energy goal of a 50% reduction in building energy consumption by reducing builder concern about using highly energy efficient wall systems.

Desjarlais, Andre Omer↗

Comparing Retrofit Wall Performance Predicted from Hygrothermal Simulations to Measurements

Over the past few years ORNL has been showing that WUFI® can be used to predict the moisture performance of walls when exposed to diffusion of water vapor, convection of moist air through the wall, and solar driven moisture. This is accomplished by comparing the hygrothermal simulation results to carefully instruments walls exposed to these phenomena in a climate chamber. In FY 2018, three stick-built walls were succumbed to typical Chicago, Illinois weather conditions in Oak Ridge National Laboratory’s Heat, Air and Moisture chamber. The measured temperature, relative humidity, and moisture content within these walls were compared with WUFI hygrothermal simulation results. In FY 2019, similar experiments and comparisons with WUFI results were completed with two walls, a structural insulated panel-based wall and a concrete masonry unit-based wall. In FY 2020, experiments were completed for a probable exterior retrofit of a wall which included adding cavity and continuous insulation. Two pairs of walls were tested by exposing them to Chicago winter weather with a positive pressure pushing outside air into the wall. The results from the FY 2020 experiments are reported here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of power conversion technology options for a self-powered furnace

A self-powered furnace is defined as one that imports no electricity: a power cycle integrated into the furnace generates all the electrical power needed, and the heat rejected by the power cycle contributes to space heating. This paper presents criteria for selection of suitable power generation technology for such a furnace. A weighting system was presented to assign weight to each criterion based on its importance to the success of a self-powered furnace implementation. Power generation candidates were reviewed and scored based on the selection criteria. The top five candidates were analyzed to quantitatively compare the additional heat exchange requirements they impose on a baseline furnace. Air-cooled internal combustion engines and microturbine generators had negligible impact on the heat exchange requirement compared to a baseline furnace. Liquid-cooled internal combustion engines increased the heat exchange requirement by a factor of 1.5. Thermoelectric generators and thermophotovoltaic increased the heat exchange requirement by a factor of roughly 2.5. Organic Rankine cycle increased the heat exchange requirement by a factor of 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validated model of a thermoelectric heat pump clothes dryer using secondary pumped loops

The energy associated with clothes drying makes up 4% of the total residential electrical energy consumption in the US. The cost is high since most clothes dryers use electric resistance heating which is inexpensive but also energy inefficient. State-of-the-art vapor-compression heat pump clothes dryers offer significant energy savings but have limited market penetration in the US. Here, a new configuration of clothes dryer was studied that utilizes a solid-state thermoelectric heat pump with pumped secondary water loops and conventional fin-and-tube water-to-air heat exchangers. Experimental results are presented for the thermoelectric dryer prototype with a combined energy factor of 6.89 lb BDW /kWh (specific moisture extraction rate of 1.71 kg w /kWh) and a dry time of 84 min for a standard load size of 8.45 lb (3.83 kg) with 57.5% starting moisture content. This is a 85% energy efficiency improvement over baseline electric resistance dryers. The efficiency and drying time results achieved are similar to vapor compression heat pump dryers. Compared to previous air-based thermoelectric clothes dryers, the energy efficiency has been increased by 6%, but drying time has been reduced by as much as 47% using secondary pumped loops and separate heat exchangers, which represents a significant advancement in the technology. In addition to the experimental prototype, a model was also developed to study the performance. The model was validated against experimental prototype data and used to identify the range of performance (dry time and efficiency) that could be expected of the design.

42 ENGINEERING↗

Comparing wall performance predicted from hygrothermal simulations to wall performance measured from environmental chamber experiments

To effectively mitigate prevailing perceptions of potential moisture risks in high-R wall assemblies, a comprehensive moisture durability assessment that incorporates BA team field evaluations, lab tests and simulations has been completed over the last couple years. In FY18, three stick-built walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The measured temperature, relative humidity and moisture content within these walls were compared to WUFI hygrothermal simulation results. In FY19, similar experiments and comparison to WUFI results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The following tasks were completed for these two walls: 1. Measure air permeance of each individual wall using ASTM E283 Standard Test Method. 2.Test walls in diffusion scenario as only moisture transport mechanism and compare measured transient temperature and relative humidity of select wall components to WUFI model results. Chicago summer and weather will be investigated. 3. Test walls in wetting event scenario and compare measured transient temperature and relative humidity of select wall components with Chicago summer weather to WUFI model results. 4. Test walls in diffusion/advection scenario. In addition to controlling outdoor chamber to match real outdoor weather, a pressure differential across the wall will be varied. Measured transient temperature and relative humidity of select wall components will be compared to WUFI model results. 5. Test walls in diffusion/advection with solar heating of cladding. In addition to the variables above, IR lamps will be used to heat the cladding on a diurnal cycle. Measured transient OSB MC and temperature will be compared to WUFI model results. This report documents the experimental method, results and comparison of the measured experimental hygrothermal performance of the two walls to simulations results.

42 ENGINEERING↗

Assessing the Potential of Active Insulation Systems to Reduce Energy Consumption and Enhance Electrical Grid Services

Building envelopes today act as passive systems in a dynamic environment. Traditional energy-saving efforts have mainly tried to improve the performance of building envelope systems by increasing thermal resistance to a set value that reduces energy flow. However, changes in weather and indoor conditions often lead to situations in which a low thermal resistance would decrease energy use. The optimization of thermal resistance that is triggered by changes in temperature, solar radiation, or availability of energy from renewable sources is currently not possible. Controllable active insulation systems (AISs), in which the thermal resistance of the insulation material can be dynamically controlled within a certain range, can expand the capabilities of the building envelope. With AISs the building envelope is no longer only a passive barrier between indoors and outdoors; instead, heat transfer can be controlled. Moreover, when AISs are combined with the thermal mass in the envelope system, these can act as thermal batteries that can be loaded and unloaded on demand. To quantify the benefits of AISs, a literature study of active insulation and achievable thermal conductivity ranges, thermal simulation models, and control logics was performed. Based on this literature study, a simulation model was developed to control the thermal resistance of insulation materials. A methodology to assess the potential of active insulation systems to reduce energy use and enhance electrical grid services was established and applied to identify ideal implementation scenarios for active insulation systems. A significant reduction of total building energy consumption for heating and cooling was found in all climate zones. The savings for the slab-on-ground DOE residential prototype building for eight selected cities in different climate zones range from 4069 kBtu to 8433 kBtu. Depending on the control cooling during peak load hours in Los Angeles could be reduced by more than 80% without a negative impact on thermal comfort conditions.

Antretter, Florian↗

Model-Based Air Flow Path Optimization of Heat Pump Clothes Dryer

A heat pump clothes dryer (HPCD) uses a vapor compression system to dry clothes. The condenser heats air, which passes through the drum to evaporate moisture out of the clothes, and the evaporator condenses water out of the air stream. As a result, the HPCD can achieve 50% energy savings compared to a conventional electric resistance dryer. In this work we developed a physics-based, quasi-steady-state HPCD system model with detailed heat exchanger and compressor models. The system model can simulate the inherently transient HPCD drying process, to size components, and to reveal trends in key variables (e.g. compressor discharge temperature, power consumption, required drying time, etc.) The system model was calibrated using experimental data from a prototype HPCD. Air leakages, in and out, along the closed air circulation path of HPCD cause varied effects on the performance. Understanding the location, magnitude, and direction of air leakage of the heat pump clothes dryer is critical for accurately characterizing the performance and developing a high-performance design. The system model was used to reveal the impacts. In addition, model-based parametric optimizations were conducted to design the HPCD charge inventory, flow rate, air path and leak points for optimum performance.

Shen, Bo↗

Experimental Measurements of Clothes Dryer Drum Heat and Mass Transfer Effectiveness

Accurate system modeling of a clothes dryer requires a drum component model that displays correct trends with respect to changing conditions. In this work, a model of drum heat and mass transfer effectiveness is adopted. Within this framework, experimental measurements of drum effectiveness are investigated with respect to several variables: drum volume, load mass, cloth type, drum volumetric air flow rate, and drum entering air temperature. These data can inform the modeling and simulation of any clothes dryer with horizontal-axis, axial-flow tumble-type clothes dryer drum.

Gluesenkamp, Kyle R.↗

A Rule-Based Expert System Applied to Moisture Durability of Building Envelopes

The moisture durability of an envelope component such as a wall or roof is difficult to predict. Moisture durability depends on all the construction materials used, as well as the climate, orientation, air tightness, and indoor conditions. Modern building codes require more insulation and tighter construction but provide little guidance about how to ensure these energy-efficient assemblies remain moisture durable. Furthermore, as new products and materials are introduced, builders are increasingly uncertain about the long-term durability of their building envelope designs. Oak Ridge National Laboratory and the US Department of Energy's Building America Program are applying a rule-based expert system methodology in a web tool to help designers determine whether a given wall design is likely to be moisture durable and provide expert guidance on moisture risk management specific to a wall design and climate. The expert system is populated with knowledge from both expert judgment and probabilistic hygrothermal simulation results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Survey of existing and emerging power conversion technologies relevant to a self-powered furnace

Furnaces for residential space heating consume about 2.5% of all annual primary energy consumed in the US. Conventional furnaces utilize electricity from the electric grid to power blowers and other components. A self-powered furnace would utilize fuel energy to generate its own power, while rejecting the waste heat from the power cycle to provide additional useful building heating. Assuming the total energy use remains the same as for a conventional furnace, there are advantages in primary energy efficiency and operating cost. With no electrical connection to the grid, the self-powered furnace also improves resiliency to electric grid outages and reduces demand on the grid, which can be important during periods of peak heating. In addition, when unit size and venting type are maintained, a drop-in replacement with no incremental installation cost and increased potential for market adoption is achieved. In this work, the power generation requirements for such a drop-in-ready, self-powered furnace are analyzed, and available power generation technologies are surveyed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probabilistic modeling of the indoor climates of residential buildings using EnergyPlus

The indoor air temperature and relative humidity in residential buildings significantly affect material moisture durability, HVAC system performance, and occupant comfort. Therefore, indoor climate data is generally required to define boundary conditions in numerical models that evaluate envelope durability and equipment performance. However, indoor climate data obtained from field studies is influenced by weather, occupant behavior and internal loads, and is generally unrepresentative of the residential building stock. Likewise, whole-building simulation models typically neglect stochastic variables and yield deterministic results that are applicable to only a single home in a specific climate. The

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

State-of-the-Art for Hygrothermal Simulation Tools

The hygrothermal (heat and moisture) performance of buildings can be assessed by utilizing simulation tools. There are currently a number of available hygrothermal calculation tools available which vary in their degree of sophistication and runtime requirements. This report investigates three of the most commonly used models (WUFI, HAMT, and EMPD) to assess their limitations and potential to generate physically realistic results to prioritize improvements for EnergyPlus (which uses HAMT and EMPD). The outcome of the study shows that, out of these three tools, WUFI has the greatest hygrothermal capabilities. Limitations of these tools were also assessed including: WUFI’s inability to properly account for air leakage and transfer at surface boundaries; HAMT’s inability to handle air leakage, precipitationrelated moisture problems, or condensation problems from high relative humidity; and multiple limitations for EMPD as a simplified method to estimate indoor temperature and humidity levels and generally not used to estimate the hygrothermal performance of the building envelope materials. In conclusion, out of the three investigated simulation tools, HAMT has the greatest modeling potential, is open source, and we have prioritized specific features that can enable EnergyPlus to model all relevant heat and moisture transfer mechanisms that impact the performance of building envelope components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A field study setup of four homes having non-ventilated and semi-conditioned sealed attics

During the 2015-2016 fiscal year and with financial support from the Florida Building Commission (FBC) and the Florida Roofing and Sheet Metal Contractors Association (FRSA ), the University of Florida (UF) and the Oak Ridge National Laboratory (ORNL) completed Phase I of a study that setup four residential home demonstrations in Florida climate zones CZ-1A and CZ-2A. UF and ORNL are evaluating the hygrothermal (heat and moisture flow) performance and durability of sealed attic construction where expanded foam insulation is applied directly to the underside of the roof deck. The four homes are instrumented for measuring temperature and relative humidity of the indoor living space, the outdoor air and the attic air. In addition, the temperature, relative humidity and moisture content of the roof sheathing are being monitored and recorded by remotely-accessible data acquisition equipment. Here, air leakage tests on the whole house, on the sealed attic and in the HVAC ducts were conducted on all four homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Durability Assessment of Selected Well-insulated Wall Assemblies

This report presents the results from studying the hygrothermal performance of two well-insulated wall assemblies, both complying with and exceeding international building codes (IECC 2015 2014, IRC 2015). The hygrothermal performance of walls is affected by a large number of influential parameters (e.g., outdoor and indoor climates, workmanship, material properties). This study was based on a probabilistic risk assessment in which a number of these influential parameters were simulated with their natural variability. The purpose of this approach was to generate simulation results based on laboratory chamber measurements that represent a variety of performances and thus better mimic realistic conditions. In total, laboratory measurements and 6,000 simulations were completed for five different US climate zones. A mold growth indicator (MGI) was used to estimate the risk of mold which potentially can cause moisture durability problems in the selected wall assemblies. Analyzing the possible impact on the indoor climate due to mold was not part of this study. The following conclusions can be reached from analyzing the simulation results. In a hot-humid climate, a higher R-value increases the importance of the airtightness because interior wall materials are at lower temperatures. In a cold climate, indoor humidity levels increase with increased airtightness. Air leakage must be considered in a hygrothermal risk assessment, since air efficiently brings moisture into buildings from either the interior or exterior environment. The sensitivity analysis of this study identifies mitigation strategies. Again, it is important to remark that MGI is an indicator of mold, not an indicator of indoor air quality and that mold is the most conservative indicator for moisture durability issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Imaging based refractometer for hyperspectral refractive index detection

Refractometers for simultaneously measuring refractive index of a sample over a range of wavelengths of light include dispersive and focusing optical systems. An optical beam including the range of wavelengths is spectrally spread along a first axis and focused along a second axis so as to be incident to an interface between the sample and a prism at a range of angles of incidence including a critical angle for at least one wavelength. An imaging detector is situated to receive the spectrally spread and focused light from the interface and form an image corresponding to angle of incidence as a function of wavelength. One or more critical angles are identified and corresponding refractive indices are determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗