Search NASA⌕ Search

Engineering topics

Bourdelle, C.

Publications and source records attributed to Bourdelle, C..

Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Nuclear fusion could offer clean, abundant energy. However, managing the power exhausted from the core fusion plasma towards the reactor wall remains a major challenge. This is compounded in emerging compact reactor designs promising more cost-effective pathways towards commercial fusion energy. Alternative Divertor Configurations (ADCs) are a potential solution. In this work, we demonstrate exhaust control in ADCs, employing a novel method to diagnose the neutral gas buffer, which shields the target. Our work on the Mega Ampere Spherical Tokamak Upgrade shows that ADCs tackle key risks and uncertainties for fusion energy. Their highly reduced sensitivity to perturbations enables active exhaust control in otherwise unfeasible situations and facilitates an increased passive absorption of transients, which would otherwise damage the divertor. We observe a strong decoupling of each divertor from other reactor regions, enabling near-independent control of the divertors and core plasma. Our work showcases the real-world benefits of ADCs for effective heat load management in fusion power reactors.

Imaging techniques↗

Divertor shaping with neutral baffling as a solution to the tokamak power exhaust challenge

Exhausting power from the hot fusion core to the plasma-facing components is one fusion energy’s biggest challenges. The MAST Upgrade tokamak uniquely integrates strong containment of neutrals within the exhaust area (divertor) with extreme divertor shaping capability. By systematically altering the divertor shape, this study shows the strongest evidence to date to our knowledge that long-legged divertors with a high magnetic field gradient (total flux expansion) deliver key power exhaust benefits without adversely impacting the hot fusion core. These benefits are already achieved with relatively modest geometry adjustments that are more feasible to integrate in reactor designs. Benefits include reduced target heat loads and improved access to, and stability of, a neutral gas buffer that ‘shields’ the target and enhances power exhaust (detachment). Analysis and model comparisons shows these benefits are obtained by combining multiple shaping aspects: long-legged divertors have expanded plasma-neutral interaction volume that drive reductions in particle and power loads, while total flux expansion enhances detachment access and stability. Containing the neutrals in the exhaust area with physical structures further augments these shaping benefits. These results demonstrate strategic variation in the divertor geometry and magnetic topology is a potential solution to one of fusion’s power exhaust challenge.

magnetically confined plasmas↗

WEST full tungsten operation with an ITER grade divertor

The mission of WEST (tungsten-W Environment in Steady-state Tokamak) is to explore long pulse operation in a full tungsten (W) environment for preparing next-step fusion devices (ITER and DEMO) with a focus on testing the ITER actively cooled W divertor in tokamak conditions. Following the successful completion of phase 1 (2016-2021), phase 2 started in December 2022 with the lower divertor made entirely of actively cooled ITER-grade tungsten mono-blocks. A boronization prior the first plasma attempt allowed for a smooth startup with the new divertor. Despite the reduced operating window due to tungsten, rapid progress has been made in long pulse operation, resulting in discharges with a pulse length of 100 s and an injected energy of around 300 MJ per discharge. Plasma startup studies were carried out with equatorial boron nitride limiters to compare them with tungsten limiters, while Ion Cyclotron Resonance Heating assisted startup was attempted. High fluence operation in attached regime, which was the main thrust of the first campaigns, already showed the progressive build up of deposits and appearance of dust, impacting the plasma operation as the plasma fluence increased. In total, the cumulated injected energy during the first campaigns reached 43 GJ and the cumulated plasma time exceeded 5 h. Demonstration of controlled X-Point Radiator regime is also reported, opening a promising route for investigating plasma exhaust and plasma-wall interaction issues in more detached regime. This paper summarises the lessons learned from the manufacturing and the first operation of the ITER-grade divertor, describing the progress achieved in optimising operation in a full W environment with a focus on long pulse operation and plasma wall interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the EUROfusion Tokamak Exploitation programme in support of ITER and DEMO

Within the 9th European Framework programme, since 2021 EUROfusion is operating five tokamaks under the auspices of a single Task Force called ‘Tokamak Exploitation’. The goal is to benefit from the complementary capabilities of each machine in a coordinated way and help in developing a scientific output scalable to future largre machines. The programme of this Task Force ensures that ASDEX Upgrade, MAST-U, TCV, WEST and JET (since 2022) work together to achieve the objectives of Missions 1 and 2 of the EUROfusion Roadmap: i) demonstrate plasma scenarios that increase the success margin of ITER and satisfy the requirements of DEMO and, ii) demonstrate an integrated approach that can handle the large power leaving ITER and DEMO plasmas. The Tokamak Exploitation task force has therefore organized experiments on these two missions with the goal to strengthen the physics and operational basis for the ITER baseline scenario and for exploiting the recent plasma exhaust enhancements in all four devices (PEX: Plasma EXhaust) for exploring the solution for handling heat and particle exhaust in ITER and develop the conceptual solutions for DEMO. The ITER Baseline scenario has been developed in a similar way in ASDEX Upgrade, TCV and JET. Key risks for ITER such as disruptions and run-aways have been also investigated in TCV, ASDEX Upgrade and JET. Experiments have explored successfully different divertor configurations (standard, super-X, snowflakes) in MAST-U and TCV and studied tungsten melting in WEST and ASDEX Upgrade. The input from the smaller devices to JET has also been proven successful to set-up novel control schemes on disruption avoidance and detachment.

ASDEX upgrade↗

Successful prediction of tokamak transport in the L-mode regime

A long standing shortfall in the predicted L-mode edge energy transport by reduced quasi-linear models of gyrokinetic turbulent transport has been resolved. The improved model TGLF-SAT2 has higher fidelity to gyrokinetic simulations of the electron-scale contribution to the electron energy transport and the ion-scale flux surface shape dependence of energy transport. The success of TGLF-SAT2 in predicting the L-mode and Ohmic edge profiles is critical to whole pulse simulation and opens the door to prediction of the H-mode power threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability analysis of WEST L-mode discharges with improved confinement from boron powder injection

WEST L-mode plasmas with dominant electron heating and no core torque source have observed improvements in confinement during boron (B) powder injection. These results are reminiscent of previous powder injection experiments on other devices and gaseous impurity seeding experiments on WEST. During powder injection, the stored energy increased up to 25% due to enhanced ion and electron heat and particle confinement. The improvements in confinement were not indicative of an L-H transition. To identify the dominant mechanisms and the causality chain behind these improvements in confinement, we employ interpretative modeling using METIS, predictive integrated modeling using a high-fidelity plasma simulator (HFPS), and stand-alone gyrokinetic simulations using quasi-linear gyrokinetic code. Interpretative modeling with METIS allowed for the estimation of missing data while maintaining good overall consistency with experiment. These results provided the initial conditions for fully predictive flux driven simulations using the HFPS. From these simulations, quasi-linear gyrokinetic analysis was performed at ρ = 0.5 and ρ = 0.65. Collisionality was found to be a strong candidate for the turbulence suppression mechanism at ρ = 0.5, while a combination of collisionality and the T e /T i ratio was found to be the likely mechanism at ρ = 0.65. The results additionally suggested that increased Z eff (through main ion dilution) could play a role in the improved confinement, but this could not be confirmed due to a lack of experimental measurements. The modeling framework established here can now be used to evaluate and exploit a variety of future powder injection experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing high performance RF heating scenarios on the WEST tokamak

High power experiments, up to 9.2 MW with LHCD and ICRH, have been carried out in the full tungsten tokamak WEST. Here, quasi non inductive discharges have been achieved allowing to extend the plasma duration to 53 s with stationary conditions in particular with respect to tungsten contamination. Transitions to H mode are observed, and H-modes lasting up to 4 s have been obtained. The increase in stored energy is weak since the power crossing the separatrix is close to the L–H threshold. Hot L mode plasmas (central temperature exceeding 3 keV) with a confinement time following the ITER L96 scaling law are routinely obtained. The weak aspect ratio dependence of this scaling law is confirmed. Tungsten accumulation is generally not an operational issue on WEST. Difficulty of burning through tungsten can prevent the discharge from accessing to a hot core plasma in the ramp-up phase, or can lead to rapid collapse of the central temperature when radiation is enhanced by a slight decrease of the temperature. Except a few pulses post-boronization, the plasma radiation is rather high (P rad /P tot ~ 50%) and is dominated by tungsten. This fraction does not vary as the RF power is ramped up and is quite similar in ICRH and/or LHCD heated plasmas. An estimate of the contribution of the RF antennas to the plasma contamination in tungsten is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developing high performance RF heating scenarios on the WEST tokamak

High power experiments, up to 9.2 MW with LHCD and ICRH, have been carried out in the full tungsten tokamak WEST. Quasi non inductive discharges have been achieved allowing to extend the plasma duration to 53s with stationary conditions in particular with respect to tungsten contamination. Transitions in H mode are obtained lasting up to 4s with weak energy increment at the power crossing the separatrix is close to the threshold. Hot L mode plasmas (Te(0)>3keV) with a confinement time following the ITER L96 scaling are routinely obtained. The weak aspect ratio dependence of this scaling law is confirmed. Tungsten accumulation is generally not an operational issue on WEST. Difficulty of burning through tungsten can prevent from accessing to a hot core plasma in the ramp-up phase or can lead to rapid collapse of the central temperature when radiation is enhanced by a slight decrease of the temperature. Apart few pulses post-boronization, the plasma radiation is rather high (Prad/Ptot~50%) and is dominated by tungsten. This fraction does not vary as the RF power is ramped up and is quite similar in ICRH and/or LHCD heated plasmas. An estimate of the contribution of the RF antennas to the plasma contamination in tungsten is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operating a full tungsten actively cooled tokamak: overview of WEST first phase of operation

WEST is an MA class superconducting, actively cooled, full tungsten (W) tokamak, designed to operate in long pulses up to 1000 s. In support of ITER operation and DEMO conceptual activities, key missions of WEST are: (i) qualification of high heat flux plasma-facing components in integrating both technological and physics aspects in relevant heat and particle exhaust conditions, particularly for the tungsten monoblocks foreseen in ITER divertor; (ii) integrated steady-state operation at high confinement, with a focus on power exhaust issues. During the phase 1 of operation (2017–2020), a set of actively cooled ITER-grade plasma facing unit prototypes was integrated into the inertially cooled W coated startup lower divertor. Up to 8.8 MW of RF power has been coupled to the plasma and divertor heat flux of up to 6 MW m –2 were reached. Long pulse operation was started, using the upper actively cooled divertor, with a discharge of about 1 min achieved. This paper gives an overview of the results achieved in phase 1. Perspectives for phase 2, operating with the full capability of the device with the complete ITER-grade actively cooled lower divertor, are also described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. The load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The geometry of the ICRF-induced wave–SOL interaction. A multi-machine experimental review in view of the ITER operation

As a part of ITPA-Integrated Operational Scenario activities, this contribution reviews recent experimental characterizations of radio-frequency (RF)-induced scrape-off layer (SOL) modifications of various tokamaks worldwide and of the LArge Plasma Device at UCLA. The phenomenology, as observed using a large variety of measurement techniques, is consistent with expectations from RF sheath rectification. Emphasis is then put on the complex three-dimensional (3D) spatial patterns of the RF–SOL interaction, in relation to the magnetic topology and the spatial distribution of RF currents over the metallic structures surrounding the RF wave launchers. Dependence on the local plasma parameters in the antenna vicinity is also briefly addressed. The final part discusses implications for future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WEST actively cooled load resilient ion cyclotron resonance heating system results

Three identical new WEST ion cyclotron resonance heating (ICRH) antennas have been designed, assembled then commissioned on plasma from 2013 to 2019. The WEST ICRH system is both load-resilient and compatible with long-pulse operations. The three antennas have been successfully operated together on plasma in 2019 and 2020, with up to 5.8 MW of coupled power. In this work, the load resilience capability has been demonstrated and the antenna feedback controls for phase and matching have been developed. The breakdown detection systems have been validated and successfully protected the antennas. The use of ICRH in combination with lower hybrid has triggered the first high confinement mode transitions identified on WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First lower hybrid current drive experiments on the WEST tokamak

The first lower hybrid current drive experiments in the full tungsten WEST tokamak are reported. Good wave coupling is found at rather low plasma current (q 95 ~4.3) and medium density (n e ~3×10 19 m -3 ). Reflection coefficient is in agreement with the expectation from the linear theory of coupling. With low reflection coefficients, 5MW was coupled for 2 seconds. High central electron temperature, up to 5keV, is achieved at ne = 3-4×10 19 m -3 . Flat and even hollow profiles of tungsten density are derived from the bolometry diagnostic. The stored thermal energy follows the H96-P scaling law with very slight degradation with density. The current drive efficiency has been assessed in low loop voltage (V L ~0.15V) discharges. Low plasma current operation and rather high effective charge (Z eff ~3) lead to modest current drive efficiency (η = 0.5-0.65 × 10 19 A.W -1 m -2 ). Long pulse operation (~30s) with high LHCD power (P LH =2.7MW) is achieved with stationary parameters, in particular electron and impurity densities, with the upper water-cooled tungsten divertor.

Goniche, M.↗