Engineering topics
Bowen, James
Publications and source records attributed to Bowen, James.
X- to Ka- Band Cryogenic LNA Module for Very Long Baseline Interferometry
We report a new result of a packaged low noise amplifier (LNA) module with wide bandwidth of 5 to 35 GHz with low noise temperature performance of 10 - 18 K, while operated at 10 K ambient. The LNA used 3-stages of sub-50 nm gate length, 100% indium channel content indium phosphide (InP) high electron mobility transistors (HEMTs). Wideband cryogenic LNAs are important for future radio astronomy observatories. To our knowledge these results represent the lowest noise achieved in a wideband amplifier from 5-35 GHz.
Ultra-wideband low noise amplifiers for the next generation very large array
We report the measured gain and noise temperatures of these LNAs.
Ka-Band High-Rate Telemetry System Upgrade for the NASA Deep Space Network
The NASA Deep Space Network (DSN) has a new requirement to support high-data-rate Category A (Cat A) missions (within 2 million kilometers of Earth) with simultaneous S-band uplink, S-band downlink and Ka-band downlink. The S-band links are required for traditional TT&C (Telemetry, Tracking, and Command) support to the spacecraft, while the Ka-band link is intended for high-data-rate science returns. The new Ka-band system combines the use of proven DSN cryogenic designs, for low system temperature, and high data rate capability using commercial telemetry receivers. The initial Cat A support is required for the James Webb Space Telescope (JWST) in 2013 and possibly other missions. The upgrade has been implemented into 3 different 34-meter Beam Waveguide (BWG) antennas in the DSN, one at each of the complexes in Canberra (Australia), Goldstone (California) and Madrid (Spain). System test data is presented to show that the requirements were met and the DSN is ready for Cat A Ka-band operational support.
A Multi-Center Controlled Study of the Acute and Chronic Effects of Cooling Therapy for MS
To determine the acute and chronic effects of cooling therapy on patients with MS using objective functional performance measures and self-assessed measures of fatigue. Cooling demyelinated nerves can reduce conduction block, potentially improving symptoms of MS. Significant acute and chronic effects of cooling have not been demonstrated in a multi-center, controlled, blinded study using objective measures of neurologic function. Patients (N=84) with definite MS, mild to moderate disability (EDSS less than 6.0), and self-reported heat sensitivity were enrolled at 5 study sites. Acute effects of cooling were assessed by randomly assigning subjects to high-dose or low-dose cooling for one hour using an active cooling vest and cap (Life Enhancement Technologies, Santa Clara, CA). Settings were individualized to maintain the cooling garments at 55 F for the high-dose treatment and 70 F for the low-dose treatment. Both patients and examining investigators were blinded to treatment assignments. The MSFC and visual acuity/contrast sensitivity were assessed before and 30 minutes after treatment. The following week, subjects had an identical visit with the alternate cooling treatment. Chronic effects of cooling were assessed by randomly assigning the same subjects to unblinded daily home cooling or observation for 4 weeks. All subjects completed the Rochester Fatigue Diary (RFD) twice weekly and subjective measures of strength, cognition, and energy level daily. At the end of the period, subjects completed the Modified Fatigue Impact Scale (MFIS) and underwent another high-dose cooling session with assessment of the MSFC and vision. After a one-week washout period, subjects crossed over to the alternate 4-week treatment. Oral temperatures were reduced with both acute treatments (0.8 +/- .06 F, high and 0.5 +/- .06 F, low). While mean MSFC did not change significantly during individual cooling sessions, post hoc analysis pooling the 3 high-dose cooling sessions revealed an improvement in MSFC scores (acute phase 0.064 +/- 0.020, p = 0.0013; chronic phase 0.044 +/- 0.021, p = 0.0368) from before to after cooling. The change in MSFC scores during the acute cooling sessions was not related to the extent of change in oral temperatures. Both the RFD score and the MFIS indicate a significantly lower fatigue level during the cooling month compared to observation (RFD, 2.53 +/- 0.83,p = 0.0033; MFIS 7.63 +/- 1.56, p = 0.0001).
Simple, low-profile, circularly polarized arrays
A low-profile, circularly polarized antenna can be made using an annular sector of strip conductor parallel to a closely spaced ground plane. This antenna has a very wide impedance bandwidth and is particularly well suited for use in series-fed arrays. Control of the excitation coefficients can be accomplished by a simple variation in the geometry of each element. Interconnection of the elements has been realized both in coaxial cable and in microstrip. Axial ratios less than 1 dB in the broadside direction are easily obtainable.