Comparison between measured turbine stage performance and the predicted performance using quasi-3D flow and boundary layer analyses

A method for calculating turbine stage performance is described. The usefulness of the method is demonstrated by comparing measured and predicted efficiencies for nine different stages. Comparisons are made over a range of turbine pressure ratios and rotor speeds. A quasi-3D flow analysis is used to account for complex passage geometries. Boundary layer analyses are done to account for losses due to friction. Empirical loss models are used to account for incidence, secondary flow, disc windage, and clearance losses. Previously announced in STAR as N84-22564

Boyle, R. J.↗

Comparison between measured turbine stage performance and the predicted performance using quasi-3D flow and boundary layer analyses

A method for calculating turbine stage performance is described. The usefulness of the method is demonstrated by comparing measured and predicted efficiencies for nine different stages. Comparisons are made over a range of turbine pressure ratios and rotor speeds. A quasi-3D flow analysis is used to account for complex passage geometries. Boundary layer analyses are done to account for losses due to friction. Empirical loss models are used to account for incidence, secondary flow, disc windage, and clearance losses.

Boyle, R. J.↗

Heat transfer in serpentine passages with turbulence promoters

Local heat transfer rates and overall pressure losses were determined for serpentine passages of square cross section. The flow entered an inlet leg, turned 180 deg and then passed through an outlet leg. Results were obtained for a passage with smooth walls for three different bend geometries and the effect of turbulence promoters was investigated. Turbulence promoters between 0.6 and 15% of the passage height were tested. Local heat transfer rates are determined from thermocouple measurements on a thin electrically heated Inconel foil and pressure drop is measured along the flow path.

Boyle, R. J.↗

Comparison of Experimental and Analytical Performance for Contoured Endwall Stators

Comparisons between predicted and experimental stator losses showed that the analysis was able to predict the change in stator loss when contoured endwalls with highly three dimensional passage geometry were used. The level of loss was predicted to within 75 percent of that measured. The predicted loss was due only to profile loss and boundary layer growth on the endwalls. The 25 percent difference was approximately 0.015 at design pressure ratio. The analysis was shown to predict the trend in stator flow angle, even for small stator geometries.

Boyle, R. J.↗

Analytic investigation of effect of end-wall contouring on stator performance

Calculations show improved stator performance when the tip end wall was contoured so that the inlet area was greater than the exit area. Comparisons are made with previously published experimental data. The results of a parametric analysis of the effect contour geometry on the efficiency of a highly loaded axial stator are given. The maximum stator efficiency gain is about 0.8 percentage point, and this represents a 22 percent reduction in stator losses. The degree to which endwall contouring reduces the forces driving secondary flows was also examined. The driving forces for both cross channel and radial secondary flow were reduced.

Boyle, R. J.↗

Effect of steam addition on cycle performance of simple and recuperated gas turbines

Results are presented for the cycle efficiency and specific power of simple and recuperated gas turbine cycles in which steam is generated and used to increase turbine flow. Calculations showed significant improvements in cycle efficiency and specific power by adding steam. The calculations were made using component efficiencies and loss assumptions typical of stationary powerplants. These results are presented for a range of operating temperatures and pressures. Relative heat exchanger size and the water use rate are also examined.

Boyle, R. J.↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. A 1,180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row were calculated and recorded along with sensor, insolation, and weather data every five minutes using a minicomputer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. An 1180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row are calculated and recorded along with sensor, insolation, and weather data every 5 minutes using a mini-computer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Thermal performance of an integrated thermal protection system for long-term storage of cryogenic propellants in space

It was demonstrated that cryogenic propellants can be stored unvented in space long enough to accomplish a Saturn orbiter mission after 1,200-day coast. The thermal design of a hydrogen-fluorine rocket stage was carried out, and the hydrogen tank, its support structure, and thermal protection system were tested in a vacuum chamber. Heat transfer rates of approximately 23 W were measured in tests to simulate the near-Earth portion of the mission. Tests to simulate the majority of the time the vehicle would be in deep space and sun-oriented resulted in a heat transfer rate of 0.11 W.

Dewitt, R. L.↗

Analytic and experimental evaluation of shadow shields and their support members for thermal control of space vehicles

The thermal performance of shadow shields, and their support struts, for the thermal protection of cryogenic propellants in a simulated deep-space environment was investigated analytically and experimentally. Very low overall heat-transfer rates were obtained when highly reflective aluminized Mylar shadow shields were used. The thermal interactions between the shields and support struts were investigated with fair to good agreement between the analysis and experimental data. The exterior surface of both fiberglass and titanium struts was coated to reduce the heat input into the test tank. The vacuum level inside the test facility strongly influenced the heat-transfer rates.

Boyle, R. J.↗

An analytical and experimental evaluation of shadow shields and their support members.

Review of the major results of an analytical and experimental program aimed at determining the potential effectiveness of shadow shields in minimizing radiant heat transfer into cryogenic propellant tanks on long-duration interplanetary missions, taking into account the thermal interaction between shields and their support structures. Analytical procedures are developed and applied that include the strut-shield interaction in predicting shadow shield performance. The results of experimental studies of the effects of configuration variables on the performance of a scale model of a shadow shield system are presented. The experimental results are used to verify the validity of analytical predictions. The results obtained show that: (1) shadow shields can be effective in reducing the heat transfer into cryogenic propellant tanks, and (2) the conductive heat transfer through supports can be reduced by selective surface coatings.

Stochl, R. J.↗

An analytical and experimental evaluation of shadow shields and their support members

Experimental tests were performed on a model shadow shield thermal protection system to examine the effect of certain configuration variables. The experimental results were used to verify the ability of an analytical program to predict the shadow shield performance including the shield-support interaction. In general, the analysis (assuming diffuse surfaces) agreed well with the experimental support temperature profiles. The agreement for the shield profiles was not as good. The results demonstrated: (1) shadow shields can be effective in reducing the heat transfer into cryogenic propellant tanks, and (2) the conductive heat transfer through supports can be reduced by selective surface coatings.

Stochl, R. J.↗

Computer program for thermal analysis of shadow shields in a vacuum

Computer program determines temperature profiles and heat transfer rates for shadow shielded cryogenic tank. Tank, shields, and thermal radiation heat source are all axisymmetric. Thermal analysis considers varying shield and tank temperatures, surface properties, and geometric arrangements. Similar heat source properties are also considered.

Boyle, R. J.↗