The Cosmic Dust Analyzer for Cassini

The Cosmic Dust Analyzer (CDA) is designed to characterize the dust envirenment in interplanetary space, in the Jovian and in the Saturnian systems. The instrument consists of two major components, the Dust Analyzer (DA) and the HIgh Rate Detector(HRD).

cosmic↗

Miniaturization in X-Ray and Gamma-Ray Spectroscopy

The paper presents advances in two new sensor and miniaturized associated electronics technologies which, when combined, can allow for very significant miniaturization, and the reduction of weight and power consumption in x-ray and gamma-ray spectroscopy systems.

Mercuric↗

Advances in the development of encapsulants for mercuric iodide X-ray detectors

Advances in the development of protective impermeable encapsulants with high transparency to ultra-low-energy X-rays for use on HgI2 X-ray detectors are reported. Various X-ray fluorescence spectra from coated detectors are presented. The X-ray absorption in the encapsulants has been analyzed using characteristic radiation from various elements. Results suggest that low-energy cutoffs for the detectors are not determined solely by the encapsulating coatings presently employed but are also influenced by the front electrode and surface effects, which can affect the local electric field or the surface recombination velocity. An energy resolution of 182 eV (FWHM) has been achieved for Ni L lines at 850 eV. Improved detector sensitivity to X-ray energies under 700 eV is demonstrated.

Iwanczyk, J. S.↗

Performance and durability of HgI2 X-ray detectors for space missions

Considerable progress has been achieved recently in HgI2 detector fabrication technology and amplification electronics. An energy resolution of 198 eV (full width at half maximum) has been obtained for the Mn k-alpha line of 5.9 keV in a practical X-ray probe without the use of cryogenic cooling. Detectors prepared with Parylene-C encapsulation have demonstrated perfect reliability in two-year tests under high vacuum and temperature and bias cycling. Other HgI2 detectors have been used to demonstrate proton-radiation-damage resistance to levels of 10 to the 12 protons/sq cm at 10.7 MeV. It is concluded that HgI2 detectors are suitable for the ordinary requirements of energy dispersive detectors in X-ray spectroscopy systems.

Iwanczyk, J. S.↗

Practical application of HgI2 detectors to a space-flight scanning electron microscope

Mercuric iodide X-ray detectors have been undergoing tests in a prototype scanning electron microscope system being developed for unmanned space flight. The detector program addresses the issues of geometric configuration in the SEM, compact packaging that includes separate thermoelectric coolers for the detector and FET, X-ray transparent hermetic encapsulation and electrical contacts, and a clean vacuum environment.

Bradley, J. G.↗

Low energy X-ray spectra measured with a mercuric iodide energy dispersive spectrometer in a scanning electron microscope

A mercuric iodide energy dispersive X-ray spectrometer, with Peltier cooling provided for the detector and input field effect transistor, has been developed and tested in a scanning electron microscope. X-ray spectra were obtained with the 15 keV electron beam. An energy resolution of 225 eV (FWHM) for Mn-K(alpha) at 5.9 keV and 195 eV (FWHM) for the Mg-K line at 1.25 keV has been measured. Overall system noise level was 175 eV (FWHM). The detector system characterization with a carbon target demonstrated good energy sensitivity at low energies and lack of significant spectral artifacts at higher energies.

Iwanczyk, J. S.↗

An electromagnetic/electrostatic dual cathode system for electron beam instruments

A method of providing cathode redundancy which consists of two fixed cathodes and uses electromagnetic and/or electrostatic fields to direct the electron beam to the electron optical axis is presented, with application to the cathode system of the Scanning Electron Microscope and Particle Analyzer proposed for NASA's Mariner Mark II Comet Rendezvous/Asteroid Flyby projected for the 1990s. The symmetric double deflection system chosen has the optical property that the image of the effective electron source is formed above the magnet assembly near the apparent position of the effective source, and it makes the transverse positions of the electron sources independent of the electron beam energy. Good performance of the system is found, with the sample imaging resolution being the same as for the single-axis cathode.

Bradley, J. G.↗

Helium concentration in the earth's lower atmosphere

A helium content of 5.222 + or - 0.017 ppm by volume has been established by measurements during 1981 of the earth's lower atmosphere, using isotope dilution mass spectrometry. This compares well with the currently accepted value of 5.239 + or - 0.004 ppm determined by Gluekhauf (1946) on the basis of measurements conducted in the 1930s. While processes that could have altered helium concentrations since the 1930s imply a significant increase in concentration, due to helium release during natural gas production, possible net helium losses from the atmosphere are not easily quantifiable.

Oliver, B. M.↗

Development of a miniature scanning electron microscope for in-flight analysis of comet dust

A description is presented of an instrument which was developed with the original goal of being flown on the International Comet Mission, scheduled for a 1985 launch. The Scanning Electron Microscope and Particle Analyzer (SEMPA) electron miniprobe is a miniaturized electrostatically focused electron microscope and energy dispersive X-ray analyzer for in-flight analysis of comet dust particles. It was designed to be flown on board a comet rendezvous spacecraft. Other potential applications are related to asteroid rendezvous and planetary lander missions. According to the development objectives, SEMPA miniprobe is to have the capability for imaging and elemental analysis of particles in the size range of 0.25 microns and larger.

Conley, J. M.↗

Ion microprobe mass analysis of plagioclase from 'non-mare' lunar samples

The ion microprobe was used to measure the composition and distribution of trace elements in lunar plagioclase, and these analyses are used as criteria in determining the possible origins of some nonmare lunar samples. The Apollo 16 samples with metaclastic texture and high-bulk trace-element contents contain plagioclase clasts with extremely low trace-element contents. These plagioclase inclusions represent unequilibrated relicts of anorthositic, noritic, or troctolitic rocks that have been intermixed as a rock flour into the KREEP-rich matrix of these samples. All of the plagioclase-rich inclusions which were analyzed in the KREEP-rich Apollo 14 breccias were found to be rich in trace elements. This does not seem to be consistent with the interpretation that the Apollo 14 samples represent a pre-Imbrium regolith, because such an ancient regolith should have contained many plagioclase clasts with low trace-element contents more typical of plagioclase from the pre-Imbrium crust. Ion-microprobe analyses for Ba and Sr in large plagioclase phenocrysts in 14310 and 68415 are consistent with the bulk compositions of these rocks and with the known distribution coefficients for these elements. The distribution coefficient for Li (basaltic liquid/plagioclase) was measured to be about 2.

Meyer, C., Jr.↗

K-Ar dating of lunar fines - Apollo 12, Apollo 14, and Luna 16.

K-Ar ages were determined on a 6-in. double-focus mass spectrometer in fines of less than 1 mm from Apollo 14 and 16, and Luna 16 lunar soil samples. Age estimates of about 2.8 AE and about 4.0 AE are suggested for the two low-K components whose presence in the samples must be assumed to accommodate the age data. An average value of 0.1849 plus or minus 0.0008 was obtained for the Ar-18/Ar-36 ratio in the solar wind from ordinate intercept correlations for the Apollo 14 and Luna 16 samples. Cosmic ray exposure ages were close to 440 m.y. for both Apollo 14 samples and close to 840 m.y. for both Luna 16 samples.

Pepin, R. O.↗