Search NASA⌕ Search

Engineering topics

Branch, Shirmir D.

Publications and source records attributed to Branch, Shirmir D..

A Free-Standing Boron-Doped Diamond Grid Electrode for Fundamental Spectroelectrochemistry

Spectroelectrochemistry (SEC) is a powerful technique that enables a variety of redox properties to be studied, including formal potential (E o ), thermodynamic values (ΔG, ΔH, ΔS), diffusion coefficient (D), electron transfer stoichiometry (n), and others. SEC requires an electrode which light can pass through while maintaining sufficient electrical conductivity. This has been traditionally composed of metal or metal oxide films atop transparent substrates like glass, quartz, or metallic mesh. Robust electrode materials like boron-doped diamond (BDD) could help expand the environments in which SEC can be performed, but most designs are limited to thin films (~100–200 nm) on transparent substrates less resilient than free-standing BDD. Here, this work presents a free-standing BDD grid electrode (G-BDD) for fundamental SEC measurements, using the well-characterized Fe(CN) 6 3–/4– redox couple as proof-of-concept. With a combination of cyclic voltammetry (CV), thin-layer SEC, and chronoabsorptometry, several of the redox properties mentioned above were calculated and compared. For E o' , n, and D, similar results were obtained when comparing the CV [E o' = +0.279 (±0.002) V vs Ag/AgCl; n = 0.97; D = 4.1 × 10 –6 cm 2 ·s –1 ] and SEC [E o' = +0.278 (±0.001) V vs Ag/AgCl; n = 0.91; D = 5.2 × 10 –6 cm 2 ·s –1 ] techniques. Both values align with what has been previously reported. To calculate D from the SEC data, modification of the classical equation used in chronoabsorptometry was required to accommodate the G-BDD electrode geometry. Overall, this work expands on the applicability of SEC techniques and BDD as a versatile electrode material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The simultaneous removal of technetium and iodine from Hanford tank waste

The simultaneous removal of radionuclides technetium-99 and iodine-129 from an actual decontaminated Hanford tank waste sample (a mixture of decontaminated waste from tanks 241-AP-105 and 241-AP-107) was demonstrated for the first time in this work. A series of commercially available ion exchange resins were evaluated in batch contact tests in the tank waste, and all showed removal of both Tc and I. The highest Tc removal was observed for Purolite A530e while the highest iodine removal was observed for ResinTech SIR-110-MP. Batch tests in simulated tank waste with these two resins showed that the SIR-110-HP-MP had consistently higher K d for both pertechnetate and iodide and much higher K d than previous works on Tc removal from Hanford waste. As such, the SIR-110-MP was evaluated in a dual -column (lead/lag) test processing 5.2L of the tank waste mixture showing 60% breakthrough of Tc on the lead column and no significant breakthrough on the lag after 625 bed volumes (BV, 6 mL size) while significant iodine breakthrough (>50%) occurred after 28 BV. The limited iodine uptake was attributed to the column conditions generating mass transfer limitations. A fraction of the Tc and I was not captured by the resin (<10%) in either the batch tests or column tests. The iodine fraction was identified to be an iodide, likely organo-iodide. The fraction of the Tc was identified as a non-pertechnetate species, which is the first time non-pertechnetate has been identified in AP-105 and AP-107 tanks, although the exact species is still unknown.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Radiolysis on Iodine Speciation in a Variety of Matrices

This report details the work conducted in fiscal year 2023 with the aim of providing a better understanding of the speciation of iodine in support of domestic 99 Mo production Shine who uses a sulfate matrix in their process. Laboratory experiments to study the behavior of iodine speciation were conducted using spectroscopic methods including UV-vis and Raman as well as electrochemical studies. Radiolysis occurring in solution presents a unique challenge that is largely unaddressed with thermodynamic modeling, therefore a kinetic model was developed to address these issues. The focus of the studies conducted this year used surrogate radiolytic conditions induced by hydrogen peroxide for comparison to radiolytic conditions from direct gamma irradiation and neat acid solutions. For each case a model incorporating the kinetics was used to predict iodine speciation in the defined conditions where the output was directly compared to the experimental conditions. Further modeling was conducted incorporating the process conditions that are specific to Shine with incorporation of radiolysis and gas sparging.

07 ISOTOPE AND RADIATION SOURCES↗

Exploring the Complex Chemistry of Uranium within Molten Chloride Salts

Harsh environments represent a unique opportunity to explore new frontiers in chemistry while developing novel tools to meet global needs. Exploring the chemistry of uranium within molten salts is a key example. Actinide chemistry within the highly ionic environment of a molten salt is poorly understood, particularly in the presence of common salt impurities or without active oxidation state control. Delving into this chemistry can provide new insight into actinide and f-electron interactions. Furthermore, expanding our chemical knowledge can also enable advances in and deployment of molten salt reactors or molten salt recycle schemes. Both molten salt applications aim towards providing green, reliable, and equitable energy as well as critical materials for the world. Here the utilization of visible absorbance and Raman spectroscopies to understand and quantify U within chloride-based salt eutectics is discussed. Furthermore, machine learning techniques in the form of chemometric modelling are developed and described, providing advanced analytical tools to quantify and characterize the U present. In conclusion, these tools are then leveraged to monitor and explore the dynamic fundamental chemistry of U within chloride-based salt melts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of Iodine, Iodide, and Iodate in Hanford Tank Waste: Technology Transfer from PNNL to Hanford 222-S Laboratory

This report summarizes the measurement of the inorganic chemical forms of iodine in Hanford tank waste. The Hanford tank wastes have roughly a part per million iodine. Part of the iodine is the long-lived beta emitter 129I, and the rest is stable 127I. Because tank waste iodine is radioactive and radiotoxic, its chemical form must be known so that its behavior in the vitrification process can be reliably known and anticipated in various waste streams (glass, secondary liquid and solid waste, and offgas emissions) at Hanford. Iodine in tank wastes exists in the inorganic chemical forms iodide and iodate (and possibly also periodate) and also as organic forms such as alkyl iodides. The measurement of organic iodides is very different from the measurement of inorganic forms and is outside the scope of this report. The inorganic chemical forms are chemically separated, in sequence, from the raw tank waste using solvent extractions and several redox reactions, then measured by ICP-MS. The inorganic chemical forms of iodine are chemically reactive, and so is the tank waste. The chemistry must be carefully designed to avoid unintended reactions that could convert one form of iodine to another during the analysis, which would skew the data and report iodine in the wrong chemical form. This iodine analysis, developed at PNNL, is being transferred to the DOE 222-S Laboratory on the Hanford Site, in Washington State, for implementation during waste processing operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Mercury Speciation and Quantification of Hanford 241-AP-107 Tank Waste Feed and Treated Samples

This report describes the second phase of a multi year project to adapt and develop an analytical technique for the low-level determination of total mercury (HgT), elemental mercury (Hg0), and monomethyl mercury (MeHg, hereafter referred to as methyl mercury) in Hanford tank waste. The focus of Phase II was to quantify the mercury (Hg) species total, elemental, and methyl mercury from a raw sample and treated (i.e., filtered and cesium-decontaminated) waste samples originating from Hanford waste tank 241-AP 107. The focus of Phase I work was to determine if mercury species can be preconcentrated from aqueous Hanford tank waste solution onto a solid adsorbent while simultaneously eliminating or very significantly reducing the parent radionuclide activity. This was demonstrated by developing protocols for the preparation, separation, and collection of total mercury and methyl mercury onto solid adsorbents, then measuring the adsorbents for radiological content at Pacific Northwest National Laboratory’s (PNNL’s) Radiochemical Processing Laboratory (RPL) on the Hanford Site. During Phase II, the Hanford tank waste material was preserved, separated (through distillation or digestion), then collected as either solid adsorbents or into liquid distillate form at the RPL and transferred to the PNNL Marine Sciences Laboratory (MSL) in Sequim, Washington, for analysis and quantification. Quantification of total, elemental, and methyl mercury was conducted under radiological control at the MSL using the ultra trace analytical capabilities available there.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and optimization of a fused-silica microfluidic device for separation of trivalent lanthanides by isotachophoresis

Abstract Elemental analysis of rare earths is essential in a variety of fields including environmental monitoring and nuclear safeguards; however, current techniques are often labor intensive, time consuming and/or costly to perform. The difficulty arises in preparing samples, which requires separating the very chemically and physically similar lanthanides. However, by transitioning these separations to the microscale, the speed, cost, and simplicity of sample preparation can be drastically reduced. Here, all fourteen non radioactive lanthanides (lanthanum through lutetium minus promethium) are separated by ITP in a serpentine fused silica microchannel in < 10 minutes with limits of detection on the order of picomoles. Electrophoretic electrodes are embedded in the microchip reservoirs so that voltage can be quickly applied and switched during operation. The limits of detection are quantified using a commercial C4D to calculate ITP zone lengths in combination with ITP theory. Optimization of experimental procedures and reproducibility based on statistical analysis of subsequent experimental results are addressed.

Bottenus, Daniel R.↗

On-line Optical Spectroscopy to Characterize Chemistry of the Transuranic Elements in Molten Salts

This project was targeted to design, build, and employ a spectroelectrochemical setup for the characterization of molten salts containing radioactive elements. This is a unique capability now housed at the Radiological Processing Laboratory (RPL) of PNNL. Initial work focused on the characterization of molten salts containing uranium, filling literature gaps regarding redox behavior, diffusion coefficients, and speciation. The setup was further modified/relocated to a glove box to allow for the study of transuranic elements, where significant research is needed to fill in literature gaps and fundamental understanding of behavior within molten salts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Separation and Speciation of Mercury from Hanford 241-AP-107 Tank Waste Supernatant

Mercuric nitrate, Hg(NO 3 ) 2 , was introduced into the Hanford flowsheet when it was used to catalyze nitric acid dissolution of certain aluminum alloy fuels and to suppress radioiodine volatilization during nitric acid dissolution of short-cooled uranium metal fuel. Inventory estimates, based primarily on Hanford process-knowledge, suggest a total mercury inventory of 2,100 kg 1 in the Hanford Tank Farms. Aside from the obvious human exposure concerns via tank vapors, mercury species in the tank waste liquid and solid fraction pose risk to the implementation and execution of the River Protection Project mission due to mercury limits imposed under waste acceptance criteria, toxicity characteristic leaching procedure restrictions for secondary waste disposal, and air emission permits. Although there is currently no processing of tank waste at Hanford, waste processing is imminent and representative mercury inventory tracking will be important to anticipate and mitigate stack emissions and secondary liquid waste disposal issues like those experienced at the Savannah River Site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In situ spectroscopic analysis and quantification of [Tc(CO)3]+ in Hanford tank waste

A Pretreatment Protocol is demonstrated for the quantitative conversion and subsequent in situ spectroscopic analysis of non-pertechnetate [Tc(CO)3]+ in tank 241-AN-102 at the Hanford Site. This conversion technique is based on a test method demonstrated using [Re(CO)3]+ in simulated Hanford tank waste. The Protocol entails adding a real waste sample containing the non-pertechnetate [Tc(CO)3]+ species to a developer solution that facilitates the rapid, quantitative conversion of the non-emissive species to a luminescent species which can then be detected spectroscopically. Three AN-102 samples were tested by the standard addition method: (1) a 5 M Na adjusted sample, (2) a sample depleted 137Cs by resin column ion exchange, (3) and an acid-stripped column eluate. The concentrations of non-pertechnetate [Tc(CO)3]+ in these samples were 7.78 × 10-6 M, 6.53 × 10-7 M, and 2.46 × 10-6 M, respectively.

Branch, Shirmir D.↗

In Situ Quantification of [Re(CO) 3 ] + by Fluorescence Spectroscopy in Simulated Hanford Tank Waste

A pretreatment protocol is presented that allows for the quantitative conversion and subsequent in situ spectroscopic analysis of [Re(CO)3]+ species in simulated Hanford tank waste. The protocol encompasses adding a simulated waste sample containing the non-emissive [Re(CO)3]+ species to a developer solution that enables the rapid, quantitative conversion of the non-emissive species to a luminescent species which can then be detected spectroscopically. The [Re(CO)3]+ species concentration in an alkaline, simulated Hanford tank waste supernatant can be quantified by the standard addition method. In a test case, the [Re(CO)3]+ species was measured to be at a concentration of 38.9 µM, which was a difference of 2.01% from the actual concentration of 39.7 µM.

fluorescence detection↗

Optically Transparent Thin-Film Electrode Chip for Spectroelectrochemical Sensing

The electrochemical and spectroelectrochemical applications of an optically transparent thin film electrode chip are investigated. The working electrode is composed of indium tin oxide (ITO); the counter and quasi-reference electrodes are composed of platinum. The stability of the platinum quasi-reference electrode is modified by coating it with a planar, solid state Ag/AgCl layer. The Ag/AgCl reference is characterized with scanning electron microscopy and energy-dispersive X-ray spectroscopy. Open circuit potential measurements indicate that the potential of the planar Ag/AgCl electrode varies a maximum of 20 mV over four days. Cyclic voltammetry measurements show that the electrode chip is comparable to a standard electrochemical cell. Randles-Sevcik analysis of 10 mM K3[Fe(CN)6] in 0.1 M KCl using the electrode chip shows a diffusion coefficient of 1.59 × 10-6 cm2/s, in comparison to the standard electrochemical cell value of 2.38 × 10-6 cm2/s. By using the electrode chip in an optically transparent thin layer electrode (OTTLE), the spectroelectrochemical modulation of [Ru(bpy)3]2+ florescence was demonstrated, achieving a detection limit of 36 nM.

Ag/AgCl↗

Non-pertechnetate Technetium Sensor Research and Development

Several significant uncertainties remain regarding the understanding and modeling of the fate and speciation of technicium-99 ( 99 Tc) in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as one or more non pertechnetate species that have not been identified and to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetate species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99 Tc in Hanford tanks and waste forms. This report summarizes work performed in FY2016 that was sponsored by the Department of Energy’s Office of Environmental Management and demonstrates the protocol for using fluorescent Tc(I)-tricarbonyl complex as a means to detect the non-pertechnetate species within tank waste solutions. The protocol was optimized with respect to ligand concentration, solvent choice, reaction temperature and time. This work culminated in the quantitation of Tc(I)-tricarbonyl within a waste simulant, using a standard addition method for measurement. This report also summarizes the synthesis and high-yield preparation of the low-valence technetium species, [Tc(CO) 3 (H 2 O) 3 ] + , which will be used as the technetium standard material for the demonstration of the non-pertechnetate species in actual wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗