Search NASA⌕ Search

Engineering topics

Brasunas, J. C.

Publications and source records attributed to Brasunas, J. C..

Composite Infrared Spectrometer (CIRS) on Cassini

The Cassini spacecraft orbiting Saturn carries the composite infrared spectrometer (CIRS) designed to study thermal emission from Saturn and its rings and moons. CIRS, a Fourier transform spectrometer, is an indispensable part of the payload providing unique measurements and important synergies with the other instruments. It takes full advantage of Cassini's 13-year-long mission and surpasses the capabilities of previous spectrometers on Voyager 1 and 2. The instrument, consisting of two interferometers sharing a telescope and a scan mechanism, covers over a factor of 100 in wavelength in the mid and far infrared. It is used to study temperature, composition, structure, and dynamics of the atmospheres of Jupiter, Saturn, and Titan, the rings of Saturn, and surfaces of the icy moons. CIRS has returned a large volume of scientific results, the culmination of over 30 years of instrument development, operation, data calibration, and analysis. As Cassini and CIRS reach the end of their mission in 2017, we expect that archived spectra will be used by scientists for many years to come.

Jennings, Donald E.↗

Thermal Infrared Spectroscopy of Saturn and Titan from Cassini

The Cassini spacecraft completed its nominal mission at Saturn in 2008 and began its extended mission. Cassini carries the Composite Infrared Spectrometer (CIRS); a Fourier transform spectrometer that measures the composition, thermal structure and dynamics of the atmospheres of Saturn and Titan, and also the temperatures of other moons and the rings.

Jennings, Donald E.↗

Titan's Surface Brightness Temperatures and H2 Mole Fraction from Cassini CIRS

The atmosphere of Titan has a spectral window of low opacity around 530/cm in the thermal infrared where radiation from the surface can be detected from space. The Composite Infrared spectrometer1 (CIRS) uses this window to measure the surface brightness temperature of Titan. By combining all observations from the Cassini tour it is possible to go beyond previous Voyager IRIS studies in latitude mapping of surface temperature. CIRS finds an average equatorial surface brightness temperature of 93.7+/-0.6 K, which is close to the 93.65+/-0.25 K value measured at the surface by Huygens HASi. The temperature decreases toward the poles, reaching 91.6+/-0.7 K at 90 S and 90.0+/-1.0 K at 87 N. The temperature distribution is centered in latitude at approximately 12 S, consistent with Titan's season of late northern winter. Near the equator the temperature varies with longitude and is higher in the trailing hemisphere, where the lower albedo may lead to relatively greater surface heating5. Modeling of radiances at 590/cm constrains the atmospheric H2 mole fraction to 0.12+/-0.06 %, in agreement with results from Voyager iris.

Jennings, Donald E.↗

Titan's Surface Temperatures Measured by Cassini CIRS

A large fraction of 19-micron thermal radiation from the surface of Titan reaches space through a spectral window of low atmospheric opacity. The emergent radiance, after removing the effect of the atmosphere, gives the brightness temperature of the surface. This atmospheric window is covered by the far-infrared channel of the Composite Infrared spectrometer1 (CIRS) on Cassini. In mapping Titan surface temperatures, CIRS is able to improve upon results of Voyager IRIS, by taking advantage of improved latitude coverage and a much larger dataset. Observations are from a wide range of emission angles and thereby provide constraints on the atmospheric opacity and radiance that are used to derive the surface temperature. CIRS finds an average equatorial surface brightness temperature of 93.7+/-0.6 K, virtually identical to the HASI temperature at the Huygens landing site. Mapping in latitude shows that the surface temperature decreases toward the poles by about 2 K in the south and 3 K in the north. This surface temperature distribution is consistent with the formation of lakes seen at high latitudes on Titan.

Jennings, Donald E.↗

Jupiter's atmospheric composition from the Cassini thermal infrared spectroscopy experiment

The Composite Infrared Spectrometer observed Jupiter in the thermal infrared during the swing-by of the Cassini spacecraft. Results include the detection of two new stratospheric species, the methyl radical and diacetylene, gaseous species present in the north and south auroral infrared hot spots; determination of the variations with latitude of acetylene and ethane, the latter a tracer of atmospheric motion; observations of unexpected spatial distributions of carbon dioxide and hydrogen cyanide, both considered to be products of comet Shoemaker-Levy 9 impacts; characterization of the morphology of the auroral infrared hot spot acetylene emission; and a new evaluation of the energetics of the northern auroral infrared hot spot.

Hydrocarbons↗

High- and Mid-temperature Superconducting Sensors for Far IR/Sub-mm Applications in Space

In this review paper an overview of the potential applications of high Tc (approx. 90 K) superconductors (HTS) and mid-Tc (approx. 39 K) superconductors (MTS) thin films in far IR/Sub-mm thermal detectors is presented. HTSs (YBCO, GdBCO etc.) were discovered in the late 80s while superconductivity in MgB2, an MTS, was discovered in 2001. The sharp transition in transport properties of HTS has allowed the fabrication of composite infrared thermal detectors (bolometers) with better figures of merit than thermopile detectors - thermopiles are currently on board the CIRS instrument on the Cassini mission to Saturn. The potential for developing even more sensitive sensors for IR/Sub-mm applications using MgB2 thin films is assessed. Current MgB2 thin film deposition techniques and film quality are reviewed.

Lakew, Brook↗

Exploring the Saturn System in the Thermal Infrared: The Composite Infrared Spectrometer

The Composite Inbred Spectrometer (CIRS) is a remote-sensing Fourier Transform Spectrometer on the Cassini orbiter that measures thermal radiation over two decades in wave number, from 10 to 1400 cm (1 mm to 7pm), with a spectral resolution that can be set from 0.5 to 20 cm. The far in portion of the spectrum (10 - 600 cm) is measured with a polarizing interferometer having thermopile detectors with a common 4-mrad field of view. The middle infrared portion is measured with a traditional Michelson interferometer having two focal planes (600 - 1100cm, 1100-1400 cm). Each focal plane is composed of a 1x10 array of HgCdTe detectors, each detector having a 0.3-mrad field of view. CIRS observations will provide three-dimensional maps of temperature, gas composition, and aerosols/condensates of the atmospheres of Titan and Saturn with good vertical and horizontal resolution, from deep in their tropospheres to high in their mesospheres. CIRS ability to observe atmospheres in the limb viewing mode (in addition to nadir) offers the opportunity to provide accurate and highly resolved vertical profiles of these atmospheric variables. The ability to observe with high-spectral resolution should facilitate the identification of new constituents. CIRS will also map the thermal and compositional properties of the surfaces of Saturn's icy satellites. It will similarly map Saturn's rings, characterizing their formation and evolution. The combination of broad spectral range, programmable spectral resolution, the small detector fields of view, and an orbiting spacecraft platform will allow CIRS to observe the Saturnian system in the thermal infrared at a level of detail not previously achieved.

Flasar, F. M.↗

High T(sub c) Superconducting Bolometer on Chemically Etched 7 Micrometer Thick Sapphire

A transition-edge IR detector, using a YBa2Cu3O(7-x) (YBCO) thin film deposited on a chemically etched, 7 micrometer thick sapphire substrate has been built. To our knowledge it is the first such high T(sub c) superconducting (HTS) bolometer on chemically thinned sapphire. The peak optical detectivity obtained is l.2 x 10(exp 10) cmHz(sup 1/2)/W near 4Hz. Result shows that it is possible to obtain high detectivity with thin films on etched sapphire with no processing after the deposition of the YBCO film. We discuss the etching process and its potential for micro-machining sapphire and fabricating 2-dimensional detector arrays with suspended sapphire membranes. A 30 micrometer thick layer of gold black provided IR absorption. Comparison is made with the current state of the art on silicon substrates.

Lakew, B.↗

Nighttime reactive nitrogen measurements from stratospheric infrared thermal emission observations

IR thermal emission spectra of the earth's atmosphere in the 700-2000/cm region were obtained with a cryogenically cooled high-resolution interferometer spectrometer on a balloon flight from Palestine, Texas, on September 15-16, 1986. The observations exhibit spectral features of a number of stratospheric constituents, including important species of the reactive nitrogen family. An analysis of the observed data for simultaneously measured vertical distributions of O3, H2O, N2O, NO2, N2O5, HNO3, and ClONO2 is presented. These measurements permit the first direct determination of the nighttime total reactive nitrogen concentrations, and the partitioning of the important elements of the NO(x) family. Comparisons of the total reactive nitrogen budget are made with the measurements by the ATMOS experiment and with the predictions of one-dimensional and two-dimensional photochemical models.

Abbas, Mian M.↗

Thermal emission spectroscopy of the middle atmosphere

The general objective of this research is to obtain, via remote sensing, simultaneous measurements of the vertical distributions of stratospheric temperature, ozone, and trace constituents that participate in the catalytic destruction of ozone (NO(sub y): NO, NO2, NO3, HNO3, ClONO2, N2O5, HNO4; Cl(sub x): HOCl), and the source gases for the catalytic cycles (H2O, CH4, N2O, CF2Cl2, CFCl3, CCl4, CH3Cl, CHF2Cl, etc.). Data are collected during a complete diurnal cycle in order to test our present understanding of ozone chemistry and its associate catalytic cycles. The instrumentation employed is an emission-mode, balloon-borne, liquid-nitrogen-cooled Michelson interferometer-spectrometer (SIRIS), covering the mid-infrared range with a spectral resolution of 0.020 cm(exp -1). Cryogenic cooling combined with the use of extrinsic silicon photoconductor detectors allows the detection of weak emission features of stratospheric gaseous species. Vertical distributions of these species are inferred from scans of the thermal emission of the limb in a sequence of elevation angles. The fourth SIRIS balloon flight was carried out from Palestine, Texas on September 15-16, 1986 with 9 hours of nighttime data (40 km). High quality data with spectral resolution 0.022 cm(exp -1), were obtained for numerous limb sequences. Fifteen stratospheric species have been identified to date from this flight: five species from the NO(sub y) family (HNO3, NO2, NO, ClONO2, N2O5), plus CO2, O3, H2O, N2O, CH4, CCl3F, CCl2F2, CHF2Cl, CF4, and CCl4. The nighttime values of N2O5, ClONO2, and total odd nitrogen have been measured for the first time, and compared to model results. Analysis of the diurnal variation of N2O5 within the 1984 and 1986 data sets, and of the 1984 ClONO2 measurements, were presented in the literature. The demonstrated ability of SIRIS to measure all the major NO(sub y) species, and therefore to determine the partitioning of the nitrogen family over a continuous diurnal cycle, is a powerful tool in the verification and improvement of photochemical modeling.

Kunde, V. G.↗

Construction and performance of a high-temperature-superconductor composite bolometer

A high-Tc superconducting bolometer has been constructed using a YBa2Cu3O(x) thin-film meander line 20 microns wide and 76,000 microns long, deposited on a SrTiO3 substrate. Radiation is absorbed by a thin film of Bi with well-characterized absorption properties deposited on a Si substrate in contact with the SrTiO3. At 1.8 Hz the measured bolometer response to a 500-K blackbody is 5.2 V/W (820 V/W extrapolated to dc). The impact of apparent nonohmic behavior at the transition is discussed, as are ways of reducing the observed 1/f noise. The response time is 32 s and is dominated by the heat capacity of the SrTiO3 substrate.

Brasunas, J. C.↗

Measurement of nighttime stratospheric N2O5 from infrared emission spectra

The mixing ratio profile of N2O5 has been inferred from high-resolution emission spectra obtained with a balloon-borne Fourier spectrometer. The observations were taken for the period from midnight to predawn on September 16, 1986 at 32 deg N latitude. The inferred volume mixing ratio from nighttime average spectra has a peak of about 1.8 x 10 to the -9th in the 32-35 altitude range. The inferred mixing ratio is generally less than the theoretical predictions from a one-dimensional model.

Kunde, V. G.↗

Atmospheric infrared emission of ClONO2 observed by a balloon-borne Fourier spectrometer

ClONO2 was observed in high-resolution infrared emission spectra obtained on Nov. 6, 1984, by a balloon-borne Fourier spectrometer. The observations took place near 0300 LT at a latitude of 35 N. Spectral simulations are used to determine the mixing ratios of ClONO2. This analysis incorporates line by line calculations and new ClONO2 cross sections measured in the laboratory at 223 K. The inferred mixing ratios of ClONO2 are 1.3 + or - 0.45 ppb and 0.98 + or - 0.35 ppb at 14 and 34 mbar. One-dimensional photochemical model predictions are compared to the observations. The ClONO2 mixing ratio at 34 mbar appears to be larger than theory, while there is agreement at 14 mbar.

Massie, S. T.↗

Infrared spectroscopy of the lower stratosphere with a balloon-borne cryogenic Fourier spectrometer

The IR limb emission of the lower stratosphere has been measured using a balloon-borne liquid nitrogen-cooled Michelson interferometer with liquid helium-cooled Si:Ga detectors. Portions of the thermal emission spectrum have been recorded between 650 and 2000/cm with an unapodized spectral resolution of 0.03/cm. This is the highest spectral resolution limb emission thus far obtained. A preliminary description is given of these data along with a discussion of the significant features. Species identified to date include CO2, O3, CFCl3, CF2Cl2, H2O, CH4, HNO3, N2O, NO2, and ClONO2. A tentative identification is made for NO, representing the first direct spectroscopic detection of NO in emission.

Kunde, Virgil G.↗

Balloon-borne cryogenic spectrometer for measurement of lower stratospheric trace constituents

A liquid-nitrogen cooled, multidetector Fourier transform spectrometer has been constructed to measure minor stratospheric constituents via high resolution, earth-limb emission spectroscopy from a balloon-borne platform. Cryogenic cooling, combined with the use of extrinsic silicon photoconductor detectors cooled to liquid-helium temperature, allows the detection of weak emission features of gaseous species. The spectrometer has two basic scan modes: the first mode records the continuous spectrum from 650-2100/cm with 0.2/cm resolution; the second simultaneously records four preselected narrow intervals (about 175/cm bandpass each) with 0.02/cm resolution, unapodized. Filtering of the interferogram signal is done by real-time, digital signal processing. The most important feature of this flat mirror Michelson system, with respect to remote balloon-borne operation, is the dynamic alignment system which maintains the relative parallelism of the two flat reflectors of the interferometer. Species identified to date in data obtained during a Nov. 6, 1984, flight include: CO2, O3, H2O, CH4, HNO3, N2O, NO2, NO, CCl3F (Freon-11) and CF2Cl2 (Freon-12).

Brasunas, J. C.↗

Use of a Fourier transform spectrometer on a balloon-borne telescope and at the multiple mirror telescope (MMT)

The design and use of an infrared Fourier transform spectrometer which has been used for observations of laboratory, stratospheric, and astronomical spectra are described. The spectrometer has a spectral resolution of 0.032/cm and has operated in the mid-infrared (12 to 13 microns) as well as the far-infrared (40 to 140 microns), using both bolometer and photoconductor cryogenic detectors. The spectrometer is optically sized to accept an f/9 beam from the multi-mirror telescope (MMT). The optical and electronic design are discussed, including remote operation of the spectrometer on a balloon-borne 102-cm telescope. The performance of the laser-controlled, screw-driven moving cat's-eye mirror is discussed. Segments of typical far-infrared balloon flight spectra, lab spectra, and mid-infrared MMT spectra are presented. Data reduction, interferogram processing, artifact removal, wavelength calibration, and intensity calibration methods are discussed. Future use of the spectrometer is outlined.

Traub, W. A.↗

Far infrared measurement of stratospheric HCl

Thermal emission from three rotational lines of H(Cl-35) and H(Cl-37) was observed with a Fourier transform spectrometer from a balloon platform at 28.9 km. The measured HCl line-of-sight density at 1.9 deg elevation above 28.9 km is 4.7 + or - 1.3 x 10 to the 15th/sq cm, implying an average volume mixing ratio of 0.8 + or - 0.2 x 10 to the -9th at the mean sampling altitude of 32.5 km. For a uniform mixing ratio model, this corresponds to a vertical column density of 2.4 + or - 0.6 x 10 to the 14th/sq cm. This result is in reasonable agreement with near infrared spectroscopic determinations and an abundance from a chemical sampling technique of HCl at this altitude; a pressure modulator radiometer measurement yields a significantly higher amount of HCl.

Chance, K. V.↗