General contamination criteria for optical surfaces

Physical models are developed for establishing criteria to decide on the acceptable contamination level of optical devices in space-borne conditions. Optical systems can be degraded in terms of decreased throughput, i.e., transmissivity or reflectivity, or increases in the total integrated scatter (TIS). Performance losses can be caused by particulate accretion, molecular film accretion, and impact cratering. A quantitative relationship is defined for film thickness and loss of throughput. Formulas are also developed for cases where induced surface defects are larger than the desired viewing wavelengths, or smaller or of the same order of the observed wavelengths. The techniques are used to quantify the degradation of a VUV solar coronagraph, a VUV stellar telescope, and a solar cell due to TIS. Applications are projected for estimating the contamination sensitivity of specific instruments, assessing the contamination hazard from known particulates, or to define clean room standards.

Bremer, J. C.↗

Baffle design for earth radiation rejection in the Cryogenic Limb-Scanning Interferometer/Radiometer

The Cryogenic Limb-Scanning Interferometer/Radiometer (CLIR) is being developed to observe infrared emissions of the earth's upper atmosphere from space. The earth's surface is an extended source of intense background radiation with a small angular separation from the desired scene. The CLIR employs an off-axis Gregorian Telescope whose primary mirror and baffles are cooled by an open-cycle cryogen system. A system of specular annular baffles has been developed to minimize both stray light problems and cryogen consumption by retro-mapping the aperture into itself. Each off-axis ray which enters the aperture and strikes the specular baffle surface is reflected so that it passes out of the aperture and is not absorbed on a cryogenic surface. The specular baffle which lies closest to the aperture is an ellipsoid whose foci trace out the circular aperture on revolution about the axis. Its theoretical 'ray trace' efficiency is 100 percent. A subsequent baffle has an elliptical cross section whose near focus traces out the central hole in the ellipsoidal baffle and whose far focus traces out the aperture. Its theoretical efficiency is about 90 percent. These baffles reduce the earth radiation heat load on the cryogenic cooler by an order of magnitude, changing it from the dominant cause of cryogen consumption to a relatively small effect. An aperture shield is also desirable to reduce cryogen consumption, stray light, and contamination.

Bremer, J. C.↗

Improvement of scanning radiometer performance by digital reference averaging

Most radiometers utilize a calibration technique in which measurements of a known reference are subtracted from measurements of an unknown source so that common-mode bias errors are cancelled. When a radiometer is scanned over a varying scene, it produces a sequence of outputs, each being proportional to the difference between the reference and the corresponding input. A reference averaging technique is presented that employs a simple digital algorithm which exploits the asymmetry between the time-variable scene inputs and the nominally constant reference input by averaging many reference measurements to decrease the statistical uncertainty in the reference value. This algorithm is, therefore, optimized by an asymmetric chopping sequence in which the scene is viewed for more than one-half of the duty cycle (unlike the analog Dicke technique). Reference averaging algorithms are well within the capabilities of small microprocessors. Although this paper develops the technique for microwave radiometry, it may be beneficial for any system which measures a large number of unknowns relative to a known reference in the presence of slowly varying common-mode errors.

Bremer, J. C.↗