Search NASA⌕ Search

Engineering topics

Brett F Bathel

Publications and source records attributed to Brett F Bathel.

At least 19 records

LED Intensity Decay Particle Tracking Velocimetry

A particle tracking velocimetry (PTV) system is demonstrated that eliminates the need for expensive lasers and cameras, and encodes the particle tracks with a known intensity variation which allows for high-resolution particle velocity and directionality determination. Using a light-emitting diode (LED) as the light source significantly reduces cost and allows for eye-safe operation, in comparison to traditional laser systems. The intensity variation control is passive, being dictated by the capacitance discharge rate in the LED pulsing circuit. The decay rate can be adjusted with the LED circuit capacitors/resistors, while the duration of the decay can be adjusted with the LED trigger pulse width. Because the intensity decay illumination is controlled by the LED, a single long exposure camera image is used to acquire images of the particle streaks, and there is no need for a more complicated and costly double-pulsing camera. With the intensity coding of the light, a single-camera/ single-LED system can identify particles entering of leaving the illumination plane, but cannot discern the direction toward or away from the camera. By using a two-color system, three-dimensionality of the particle tracks can be determined.

Joshua M Weisberger↗

Characterization of Rochon Prisms for Bi-Directional Imaging Applications

Polarizing prisms are often used in applications where light is split into two separate beams of orthogonal polarization, or to isolate a beam with a preferred polarization state. These prisms are typically used with lasers, but there are applications of their use with imaging systems. One such example is that of a recently developed focusing schlieren system, where light must be transmitted through a Rochon prism in both the forward and backward directions. Three Rochon prisms were characterized in this study in terms of their transmitted intensity and polarization state: a quartz/quartz prism, a glass/quartz prism, and a MgF2/MgF2 prism. Laser testing at four wavelengths was performed, along with full clear aperture collimated LED light testing at a single wavelength. The glass/quartz and MgF2/MgF2 prisms operated in the same manner when light was transmitted in either the forward or backward direction. The quartz/quartz prism, however, exhibited differences between operation in the forward and backward direction. In the forward orientation for input plane polarized light, the transmitted intensity varied sinusoidally as a function of height of incidence through the prism, while the polarization of the unrefracted and refracted beams were uniform and orthogonally polarized. In the backward orientation, the intensity for both unrefracted and refracted beams was uniform, but the azimuthal orientation of the output plane polarized light varied sinusoidally as a function of height of incidence through the prism, while remaining orthogonally polarized between the two beams at each position.

Joshua M Weisberger↗

Simultaneous Focused Laser Differential Interferometry and High-Speed Schlieren in a Mach 6 Flow

An instrument is demonstrated that is capable of simultaneous and independent flow density fluctuation measurements over the same line-of-sight by combining two optical techniques: focused laser differential interferometry (FLDI) and high-speed schlieren (HSS). The FLDI instrument measures fluctuations at a single point in the flowfield at 10 MHz, with the resulting signal most sensitive in the region nearest the focal plane of the FLDI laser beam. The HSS instrument acquires images at 20 kHz along the same optical axis as the FLDI beam, but with the resulting signal path averaged over the entire HSS line-of-sight. The introduction of the HSS optics into the FLDI beam path provides two high-quality measurement capabilities in a single system with no degradation of performance relative to stand-alone FLDI or HSS instruments.

Focused Laser Differential Interferometry↗

Multi-Point Line Focused Laser Differential Interferometer for High-Speed Flow Fluctuation Measurements

A multi-point focused laser differential interferometer (FLDI) has been developed to measure density fluctuations at 16 points along a line. A pair of cylindrical lenses on the transmitter side of a conventional single-point FLDI instrument form two closely spaced (≤200 μm), orthogonally polarized, parallel laser lines at the instrument’s focus. On the receiver side of the instrument, the interference of the beams on a 16-element photodiode array results in a single line of measurements. The further addition of a Nomarski prism creates two separate measurement lines, and the addition of a second photodiode array to the instrument enables simultaneous measurements of density fluctuations along the two lines separated by several millimeters. These two lines of measurement can be conveniently oriented at any azimuthal angle relative to the instrument’s optical axis on the measurement plane, coinciding with the instrument’s focus. Two experiments were performed to demonstrate the capabilities of the instrument. In the first experiment, a laser-induced breakdown spark generated a traveling spherical shock wave, and measurements of the resulting density disturbance and wave velocity were obtained. These results were compared to high-speed schlieren images of the shock wave acquired at 400 kHz. In the second experiment, the multi-point FLDI instrument was used to measure density disturbances in the boundary layer of a flat plate in a Mach 6 freestream flow. The measurements were made along two lines, both approximately 6 mm in length, extending from the surface of the plate through the boundary layer. High-speed schlieren images were acquired at 100 kHz during separate wind tunnel runs at matching unit Reynolds numbers to visualize the unsteady boundary layer flow and compare to the FLDI measurements.

Laser beam shaping↗

High-Speed Schlieren Analysis of Retropropulsion Jet in Mach 10 Flow

High-speed schlieren imaging of a 5-in.-diam, 70° sphere-cone model with a single centerline 15° half-angle nozzle was performed in a Mach 10 flow. Image sequences captured at 100 kHz were obtained with the nozzle plugged (fully blunted model), no nozzle flow, and with nozzle flow over a range of supply pressures. The freestream unit Reynolds number was kept constant for all runs at3.38×106m−1. Time-average information pertaining to the location, width, and stand-off distance of the bow shock, interface, terminal shock, and triple point as a function of jet pressure ratio are presented based on analysis of covariance images from each run. Measurement of jet plume boundary shape as a function of jet pressure ratio is also presented. Analyses of frequency content associated with the jet structure are shown, as are results of the proper orthogonal decomposition of these data. For all runs with nozzle flow, a dominant fundamental frequency of 2 kHz was observed. Finally, a discussion of bow shock unsteadiness resulting from interaction with freestream disturbances for the blunted and no nozzle flow is provided, as is a discussion on the formation of weak waves emanating from the bow shock resulting from this interaction.

Brett F Bathel↗

Analysis of the Two-Level NO PLIF Model for Low-Temperature High-Speed Flow Applications

The current work compares experimentally obtained nitric oxide (NO) laser-induced fluorescence (LIF) spectra with the equivalent spectra obtained analytically. The experimental spectra are computed from captured images of fluorescence in a gas cell and from a laser sheet passing through the fuel-air mixing flowfield produced by a high-speed fuel injector. The fuel injector is a slender strut that is currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. This injector is placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number airflow at the entrance of a scramjet combustor, and injects helium, which is used as an inert substitute for hydrogen fuel. Experimental planar (P) LIF is obtained by using a UV laser to excite fluorescence from the NO molecules that are present in either a gas cell or the facility air used for the EIMP experiments. The experimental data are obtained for several segments of the NO fluorescence spectrum. The selected segments encompass LIF lines with rotational quantum numbers appropriate for low-to-moderate temperature flows similar to those corresponding to the nominal experimental flow conditions. The experimental LIF spectra are then evaluated from the data and compared with those obtained from the theoretical models. The theoretical spectra are obtained from LIFBASE and LINUS software, and from a simplified version of the two-level fluorescence model. The equivalent analytic PLIF images are also obtained by applying only the simplified model to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield. Good agreement between the experimental and theoretical results provides increased confidence in both the simplified LIF modeling and CFD simulations for further investigations of high-speed injector performance using this approach.

Tomasz G Drozda↗

TPSAS-NF1676L-30534-DND

Explore the source record for details and available documents.

Connor C McDougall↗

Progress on the Development of a Step Height Sensor for the BOLT Flight Vehicle

This presentation will summarize progress on the development of a step height sensor for the BOLT flight vehicle. Two methods have been proposed to measure the step size in this effort.The first method involves the application of miniaturized camera embedded in the flight vehicle that views the step through a rearward-facing port (shown in Fig. 1a inset). The second method involves the application of a linear fiber optic array bundle to measure the intensity of light reflected back from the aft body step (concept shown in Fig. 1b). Preliminary testing with the miniaturized camera has been performed in the lab and shows that displacements of ≤10 μm can be measured using this method. Final testing with both methods will be performed on the test stand shown in Fig. 1a. This test stand will include a fine adjustment vertical translation stage that will be used to adjust the step height in steps of 1-2 μm. A high-magnification imaging system will also be used to verify the step height. The miniaturized camera and linear fiber optic array bundle will be mounted in one of several port holes with varying degrees of inclination relative to the top surface in the opposing aft-section slab. BOLT flight vehicle details and information on the steps can be found in Ref. [1].

BOLT↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗

Two-Line Focused Laser Differential Interferometry of a Flat Plate Boundary Layer at Mach 6

Cylindrical optics have been added to a conventional two-point focused laser differential interferometry (FLDI) system to make measurements of density fluctuations at multiple points along two lines. Optics fixed in rotation mounts allow for the two lines to be oriented in any position relative to each other to make measurements of different physical phenomena. The system was first characterized in the laboratory using a laser-induced breakdown spark to provide a well-defined density fluctuation. The system was then installed at the NASA Langley 20 Inch Mach 6 Air Tunnel to make measurements through the boundary layer of a flat plate model and in the tunnel free stream.

Joshua M Weisberger↗

Two-Line Focused Laser Differential Interferometry of a Flat Plate Boundary Layer at Mach 6

Flat plate models are often used in wind tunnel testing to make measurements of the boundary layer, but preclude the use of conventional focused laser differential interferometry (FLDI) measurements, particularly for measurements at the surface of the model. By instead focusing light in only one direction using cylindrical optics, as opposed to two directions using only spherical optics, FLDI measurements can be made without truncating the beam at the model edges. Measurements at discrete points along a line can also be acquired, effectively acting as many individual FLDI instruments in a single measurement. Here, a two-line FLDI system has been constructed that allows for the measurement lines to be easily oriented at any azimuthal angle about the optical axis since the optics are housed in rotation mounts. Velocity measurements at points along a line or between two lines are also possible, since the beams are split similar to the two-point FLDI instrument. The system was first characterized in the laboratory using a laser-induced breakdown spark to provide a well-defined density fluctuation, along with high-speed schlieren measurements for comparison. The system was then installed at the NASA Langley 20-Inch Mach 6 Air Tunnel to make measurements through the boundary layer of a flat plate model and in the tunnel freestream.

Joshua M Weisberger↗

Development of a Terrain Mapping/Crater Evolution Measurement using Diffractive Optical Elements

When landing on the moon, understanding the interaction of the engine exhaust plume with the lunar surface is critical for the success of the descent and landing flight phases. Two evaluation tools currently used are computational simulations and ground test measurements. Computational simulations require experimental measurements for comparison/validation, but ground test measurements cannot accurately emulate all aspects of an actual lunar landing; flight tests remain the only method of obtaining fully representative data. A terrain mapping/crater evolution measurement system was developed for potential inclusion on a future lander mission. This system uses two stereo cameras viewing a laser dot grid pattern projected on the ground, where the grid is created by shining a laser through one or two diffractive optical elements. CAD simulations of the stereo imaging system are first used to validate the proposed design. Laboratory testing of the system using both a large-scale fixed-geometry crater and a small-scale evolving-geometry crater validate the use of the system for terrain mapping measurements, and for its potential inclusion on a future lander mission.

Joshua M Weisberger↗

Development of a Self-Aligned Compact Focusing Schlieren System for NASA Test Facilities

A novel compact, inherently self-aligned focusing schlieren system is presented for use in experiments that require flow visualization. Unlike existing focusing schlieren systems that require a separate, and precisely aligned, source grid and cutoff grid to achieve sensitivity to density gradients, this system projects an image of a physical grid element onto a background and then reimages this projection back onto the physical grid element thereby achieving self-alignment. Further, unlike existing focusing schlieren systems where the image of the source grid is physically translated relative to the cutoff grid to achieve sensitivity to density gradients, a polarization prism in the system acts on the polarization state of the light of the projected grid element to provide sensitivity adjustment. By adjusting the position of the prism along the optical axis of the instrument, changes to the sensitivity can be realized. Since the outgoing and returning light used to project an image of the grid element are orthogonally polarized to one another, reflections from windows that may be present between the lens and background of the system can be eliminated. The system can also be implemented in test facilities where optical access is limited and/or exists on only one side. A discussion on different aspects of the development of this technology is provided, as are sample images from the system at the different stages of development. Images that demonstrate the ability to make on-the-fly adjustments to the instrument's field-of-view and working distance are also presented.

Brett F Bathel↗

A Comparison of NO Laser-Induced Fluorescence Models at Conditions Relevant to Supersonic and Hypersonic Flows

Planar laser-induced fluorescence (PLIF) of the nitric oxide (NO) molecule has been widely used in wind tunnel facilities for flow visualization, velocity, and temperature measurements. The experimental PLIF measurements are often compared with synthetic PLIF images using computationally derived temperatures, pressures, velocities, and species mole fractions. This approach is commonly referred to as computational flow imaging (CFI). In the present work, we compare signal intensity from PLIF models with experimental PLIF measurements obtained within a low pressure gas cell system at pressures and NO mole fractions relevant to supersonic and hypersonic flowfields. Experimental measurements were compared to several different laser induced-fluorescence models reported in the literature including LIFBASE, LINUS, and a NASA two-level model. The experimental measurements agreed well with all of the models at lower pressures and lower NO mole fractions; the fluorescence there is linear with both of these parameters. However, at higher pressures and mole fractions, the signal becomes nonlinear with respect to these parameters as self-quenching limits the signal and absorption further limits the signal. In fact, for the experimental path length of the experiment, the combination of high pressure and high NO mole fraction causes the experimental results to deviate significantly from the predicted results that neglect absorption of the incident laser sheet. The LINUS model, which allows absorption to be calculated, provided results that agreed better with the experimental measurements. Since supersonic and hypersonic flowfields may contain a region of the flow with high pressures and measurements in large-scale facilities often include a long path length, neglecting absorption may have a significantly negative effect on the CFI comparison to experimental PLIF images. As a result, PLIF models that account for absorption should be included in computational flow imaging approaches for laser induced fluorescence.

laser-induced fluorescence↗

Linear Array Photodiode and Data Acquisition System Development for Multi-Point Line FLDI Measurements

The continuous development and advancement of multi-point line focused laser differential interferometry (FLDI) instruments requires larger numbers of acquisition channels to make more finely spatially resolved measurements of high-frequency flow fluctuations. No current off-the-shelf system exists for these line FLDI measurements, and so a single unified system consisting of a linear array photodiode, required electronics, and a data acquisition system has been developed to enhance the measurement resolution, both spatially and temporally. A printed circuit board was developed on which the linear array photodiode is mounted for inclusion into an existing FLDI system, and amplifier breakout boards incorporate electronics to condition the signal for the data acquisition system while retaining the necessary high frequency response. The data acquisition system uses a National Instruments chassis and multiple oscilloscope modules, with a specially-designed LabVIEW user interface for laboratory and wind tunnel setup, calibration, and testing. Details regarding the development of the linear array photodiode system and the data acquisition system are provided, and systematic testing of all components is presented, culminating in a test of the system integrated into an existing line FLDI system for measurements of a turbulent jet.

Joshua M Weisberger↗