Search NASA⌕ Search

Engineering topics

Brewer, J.

Publications and source records attributed to Brewer, J..

Bio-inspired gas sensing: boosting performance with sensor optimization guided by “machine learning”

The performance of existing gas sensors often degrades in field conditions because of the loss of measurement accuracy in the presence of interferences. Thus, new sensing approaches are required with improved sensor selectivity. We are developing a new generation of gas sensors, known as multivariable sensors, that have several independent responses for multi-gas detection with a single sensor. In this study, we analyze the capabilities of natural and fabricated photonic three-dimensional (3-D) nanostructures as sensors for the detection of different gaseous species, such as vapors and non-condensable gases. We employed bare Morpho butterfly wing scales to control their gas selectivity with different illumination angles. Next, we chemically functionalized Morpho butterfly wing scales with a fluorinated silane to boost the response of these nanostructures to the vapors of interest and to suppress the response to ambient humidity. Further, we followed our previously developed design rules for sensing nanostructures and fabricated bioinspired inorganic 3-D nanostructures to achieve functionality beyond natural Morpho scales. These fabricated nanostructures have embedded catalytically active gold nanoparticles to operate at high temperatures of ≈300 °C for the detection of gases for solid oxide fuel cell (SOFC) applications. Our performance advances in the detection of multiple gaseous species with specific nanostructure designs were achieved by coupling the spectral responses of these nanostructures with machine learning (a.k.a. multivariate analysis, chemometrics) tools. Our newly acquired knowledge from studies of these natural and fabricated inorganic nanostructures coupled with machine learning data analytics allowed us to advance our design rules for sensing nanostructures toward the required gas selectivity for numerous gas monitoring scenarios at room and high temperatures for industrial, environmental, and other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Muon Spin Rotation/Relaxation Study of Ba2CoO4

A positive muon spin rotation and relaxation ({mu}{sup +}SR) experiment on a single crystal of Ba{sub 2}CoO{sub 4} indicates the existence of an antiferromagnetic (AF) transition occurring at T{sub N} {approx} 24 K. Weak transverse field measurements show that the paramagnetic volume fraction of the sample decreases rapidly at the magnetic transition, indicating a bulk effect which cannot be due to the presence of impurities. Zero-field measurements reveal the presence of a magnetically ordered state below T{sub N} with at least three crystallographically inequivalent muon sites. The results are compared to recent magnetic susceptibility and neutron measurements. Of the two AF spin structures proposed to explain recent neutron experiments, the {mu}{sup +}SR results clearly exclude the one involving AF order along the c axis while supporting that with AF order in the ab plane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser Calibration Experiment for Small Objects in Space

The Air Force Research Laboratory/Directed Energy Directorate (AFRL/DE) and NASA/Marshall Space Flight Center (MSFC) are looking at a series of joint laser space calibration experiments using the 12J 15Hz CO2 High Performance CO2 Ladar Surveillance Sensor (FU-CLASS) system on the 3.67 meter aperture Advanced Electro-Optics System (AEOS). The objectives of these experiments are to provide accurate range and signature measurements of calibration spheres, demonstrate high resolution tracking capability of small objects, and support NASA in technology development and tracking projects. Ancillary benefits include calibrating radar and optical sites, completing satellite conjunction analyses, supporting orbital perturbations analyses, and comparing radar and optical signatures. In the first experiment, a Global Positioning System (GPS)/laser beacon instrumented microsatellite about 25 cm in diameter will be deployed from a Space Shuttle Hitchhiker canister or other suitable launch means. Orbiting in low earth orbit, the microsatellite will pass over AEOS on the average of two times per 24-hour period. An onboard orbit propagator will activate the GPS unit and a visible laser beacon at the appropriate times. The HI-CLASS/AEOS system will detect the microsatellite as it rises above the horizon, using GPS-generated acquisition vectors. The visible laser beacon will be used to fine-tune the tracking parameters for continuous ladar data measurements throughout the pass. This operational approach should maximize visibility to the ground-based laser while allowing battery life to be conserved, thus extending the lifetime of the satellite. GPS data will be transmitted to the ground providing independent location information for the microsatellite down to sub-meter accuracies.

Campbell, Jonathan↗

Nickel-hydrogen battery state of charge during low rate trickle charging

The NASA AXAF-I program requires high battery state of charge at launch. Traditional approaches to providing high state of charge, during prelaunch operations, require significant battery cooling. The use of active cooling, in the AXAF-I prelaunch environment, was considered and proved to be difficult to implement and very expensive. Accordingly alternate approaches were considered. An approach utilizing adiabatic charging and low rate trickle charge, was investigated and proved successful.

Lurie, C.↗

Nickel-hydrogen battery state of charge during low rate trickle charging

Battery temperature increase, due to low rate trickle charging, has been determined experimentally, using a six cell battery module in a test setup simulating the anticipated AXAF-1 prelaunch environment. Test results indicate trickle charge rates less than or equal to the self discharge rate do not increase dissipation beyond that due to the self discharge. Significant trickle charge rates (approximately C/500) result in battery temperatures only a few degrees (F) higher than those observed during periods of open circuit stand.

Lurie, C.↗