Velocimetry Overview for visitors from the DOD

We are in the midst of a transformative period in which technological advances are making fundamental changes in the measurement techniques that form the backbone of nuclear weapon certification. Optical velocimetry has replaced electrical shorting pins in “Hydrotests,” which measure the dynamic implosion process. This advance has revolutionized nuclear weapons certification during the last 5 years. We can now measure the implosion process that drives a nuclear detonation with many orders of magnitude more resolution in both space and time than was possible just 10 years ago. It has been compared to going from Morse Code to HDTV, resulting in a dozen or more improvements in models of these weapons. These Hydrotests are carried out at LANL, LLNL and the NNSS, with the later holding the important role of allowing us to test with nuclear materials, in sub-critical configurations (i.e., no yield.) Each of these institutions has largely replaced pins with hundreds of channels of optical velocimetry. Velocimetry is non-contact and is used simultaneously with the X-ray capability of these facilities. The U1-a facility at NNSS pioneered this approach in the Gemini series in 2012, and continues to lead, both in channel count and technological advances. Close cooperation among LANL, LLNL and NSTec in these advances serves the complex by leveraging capabilities across sites and accelerating the pace of technical improvements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Establishing precision and accuracy in PDV results

We need to know uncertainties and systematic errors because we create and compare against archival weapons data, we constrain the models, and we provide scientific results. Good estimates of precision from the data record are available and should be incorporated into existing results; reanalysis of valuable data is suggested. Estimates of systematic errors are largely absent. The original work by Jensen et al. using gun shots for window corrections, and the integrated velocity comparison with X-rays by Schultz are two examples where any systematic errors appear to be <1% level.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Velocimetry from details to the big picture and back

Slides used by Matthew Briggs for a talk given at the Colorado School of Mines. Points in this talk are summarized as follows: 1) Because velocity is one of the fundamental quantities in the physical description of shock physics, and because it can now be measured with nanosecond time resolution, <1% accuracy, for 100s of channels in a small confined space, optical velocimetry is growing dramatically in applications to shock physics. 2) Velocimetry is one of many critical pieces in the weapons labs mission to certify our nations stockpile. 3) The breadth of this mission means a very wide array of opportunities at LANL and other weapons labs.

47 OTHER INSTRUMENTATION↗

Influence of sweeping detonation-wave loading on damage evolution during spallation loading of tantalum in both a planar and curved geometry

Widespread research over the past five decades has provided a wealth of experimental data and insight concerning the shock hardening, damage evolution, and the spallation response of materials subjected to square-topped shock-wave loading profiles. However, fewer quantitative studies have been conducted on the effect of direct, in-contact, high explosive (HE)-driven Taylor wave (unsupported shocks) loading on the shock hardening, damage evolution, or spallation response of materials. Systematic studies quantifying the effect of sweeping-detonation wave loading are yet sparser. In this study, the damage evolution and spallation response of Ta is shown to be critically dependent on the peak shock stress, the geometry of the sample (flat or curved plate geometry), and the shock obliquity during sweeping-detonation-wave shock loading. Sweepingwave loading in the flat-plate geometry is observed to: a) yield a lower spall strength than previously documented for 1-D supported-shock-wave loading, b) exhibit increased shock hardening as a function of increasing obliquity, and c) lead to an increased incidence of deformation twin formation with increasing shock obliquity. Sweeping-wave loading of a 10 cm radius curved Ta plate is observed to: a) lead to an increase in the shear stress as a function of increasing obliquity, b) display a more developed level of damage evolution, extensive voids and coalescence, and lower spall strength with obliquity in the curved plate than seen in the flat-plate sweeping-detonation wave loading for an equivalent HE loading, and c) no increased propensity for deformation twin formation with increasing obliquity as seen in the flat-plate geometry. The overall observations comparing and contrasting the flat versus curved sweeping-wave spall experiments with 1D loaded spallation behavior suggests a coupled influence of obliquity and geometry on dynamic shock-induced damage evolution and spall strength. Coupled experimental and modeling research to quantify the combined effects of sweeping-wave loading with increasingly complex sample geometries on the shockwave response of materials is clearly crucial to providing the basis for developing and thereafter validation of predictive modeling capability.

36 MATERIALS SCIENCE↗

Ranchero Armature Test LA-19.4-CT-3: PBX-9501 Explosive with no smoothing layer. Firing point 88, 9/16/13

LA-19.4-CT-3 (CT-3) was the third camera test in a series beginning in 1/11, which diagnose the performance of 6 mm thick, 6061 T-0 Al Ranchero armatures. [The test LA-43-CT-2 (CT-2) is described in LA-UR-14-21983.] The goal of CT-3 was to verify that PBX-9501, with 18 mm point spacing and no smoothing layer, could be used for Ranchero generator armatures in place of PBXN-110, which had been used in all previous Ranchero applications. CT-1 and CT-2 both had 43 cm long slapper detonator systems imbedded in the cast PBXN-110 explosive, but manufacturing a charge for a similar 9501 test was not cost effective. Instead, a single cylinder of 9501, 19.368 cm long and 15.494 cm (6.100”)in diameter, had a groove machined to accommodate a row of 11 SE-1 detonators with 18 mm point spacing along the mid-plane of the cylinder. The expansion of the armature looks like a slapper assembly along almost ½ of the circumference, and provides adequate proof of concept. Removing the smoother from PBXN-110-driven armatures increased the armature velocity from 3.1 mm/μs to 3.3 mm/μs, as seen in CT-2, and the velocity measured on CT-3 increased to 3.8 mm/μs. In addition, the camera records show that the surface of the armature is smooth enough, and free from ruptures for an expansion of greater that 2X. The advantage of using 9501 is that it precludes concerns about blow-outs seen when bubbles are left in the cast material, and gives extra velocity. The disadvantage is that the machined explosives are more expensive.

42 ENGINEERING↗

Ranchero Armature Test LA-43-CT-2: PBXN-110 Explosive with no smoothing layer. Lower Slobovia, 6/13/13

This test, documented as LA-43-CT-2, was performed to verify calculations which indicate that the smoothing layer employed for Ranchero Armatures is not required when the slapper point spacing is 18 mm (“On the efficacy of an acrylic layer in the Ranchero armature,” Bob Watt, published in “Ranchero Status Report” LA-14463). [Naming this test –CT-2 acknowledges the previous test performed during 1/11 as the initial test in the series, and we will refer to that test as LA-43-CT-1 in the future.] In addition, higher velocity is achieved when the volume occupied by the smoother is replaced by HE. Two framing cameras were used on the shot, and a 20 point PDV array was fielded to ascertain armature performance in specific conditions. The conclusions are that the armature is smooth enough, and the terminal velocity is increased from ~3.1 mm/μs to ~3.3 mm/μs. The armature tested had casting voids in the HE that were observed in pre-test inspections, and were expected to cause ruptures. (See Appendix 3 of the Ranchero Status Report.) Such “blowouts” were observed in all three locations identified in pre-shot inspection. In addition, ruptures occurred in locations having no pre-shot indication of a problem. These unpredicted blowouts have a difference in appearance from those typically seen. Further visual examination of the inspection radiographs do not reveal the cause, and that is a serious concern for future efforts with such castings. A path forward will include attempting to digitize the inspection x-rays for the charge tested, to see if the cause of the “new” ruptures can be found via computer enhancement. In addition, there are two additional armatures from the same casting lot, and these might also be tested to see if there is some problem with the HE or the armature material in this batch. For now, this plan is on hold, pending the outcome of tests and cost estimates related to using PBX-9501 in place of the PBXN-110. Casting issues would be eliminated in such configurations.

42 ENGINEERING↗

Note: Simultaneous measurement of transverse speed and axial velocity from a single optical beam

A method is introduced for simultaneously measuring transverse speed and axial velocity using a single optical beam and a standard photon Doppler velocimetry (PDV) sensing architecture. This result is of particular interest given the recent, widespread use of PDV and the fact that optical velocimetry has thus far been limited to measuring motion in one dimension per probe. Further, this result demonstrates that both axial velocity data and transverse speed data (at least qualitative) may be obtained entirely through signal analysis; not requiring hardware modification. This result is immediately relevant to analyses of existing PDV data and to future efforts in high-speed optical velocimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Flight of the Zeno Experiment on USMP-3

The second flight of the Zeno experiment in the USMP-3 flight has shown successful control of density perturbations near the window surfaces. These density changes were demonstrated to be arising from the rate of temperature change in the sample cell during the flight. These effects could be controlled by using decreasing ramp rates as Tc was approached. The cell window interference was carefully recorded to provide data about the phase of the interference close to the critical point and the effective window reflectivity. Correlograms were recorded from 500 mili K down to 2 mili K at 24 temperatures, 383 correlograms in all. The efforts to get closer were prevented by a long (greater than two week time constant) decay of a 1.3% density error caused by local heating from the 17 micro W laser beam. The phase boundary was located with unprecedented precision of +/- 2O micro K. The complete experiment sequence was done with ground commanding and uploaded script files, bypassing the original autonomous-mode program sequence.

Gammon, Robert W.↗

Zeno: Critical Fluid Light Scattering Experiment

The Zeno (Critical Fluid Light Scattering) experiment is the culmination of a long history of critical fluid light scattering in liquid-vapor systems. The major limitation to making accurate measurements closer to the critical point was the density stratification which occurs in these extremely compressible fluids. Zeno was to determine the critical density fluctuation decay rates at a pair of supplementary angles in the temperature range 100 mK to 100 (mu)K from T(sub c) in a sample of xenon accurately loaded to the critical density. This paper gives some highlights from operating the instrument on two flights March, 1994 on STS-62 and February, 1996 on STS-75. More detail of the experiment Science Requirements, the personnel, apparatus, and results are displayed on the Web homepage at http://www.zeno.umd.edu.

Gammon, Robert W.↗

Highlights of the Zeno Results from the USMP-2 Mission

The Zeno instrument, a High-precision, light-scattering spectrometer, was built to measure the decay rates of density fluctuations in xenon near its liquid-vapor critical point in the low-gravity environment of the U.S. Space Shuttle. Eliminating the severe density gradients created in a critical fluid by Earth's gravity, we were able to make measurements to within 100 microKelvin of the critical point. The instrument flew for fourteen days in March, 1994 on the Space Shuttle Columbia, STS-62 flight, as part of the very successful USMP-2 payload. We describe the instrument and document its performance on orbit, showing that it comfortably reached the desired 3 microKelvin temperature control of the sample. Locating the critical temperature of the sample on orbit was a scientific challenge; we discuss the advantages and short-comings of the two techniques we used. Finally we discuss problems encountered with making measurements of the turbidity of the sample, and close with the results of the measurement of the decay rates of the critical-point fluctuations.

Gammon, Robert W.↗

Statistical fitting accuracy in photon correlation spectroscopy

Continuing our experimental investigation of the fitting accuracy associated with photon correlation spectroscopy, we collect 150 correlograms of light scattered at 90 deg from a thermostated sample of 91-nm-diameter, polystyrene latex spheres in water. The correlograms are taken with two correlators: one with linearly spaced channels and one with geometrically spaced channels. Decay rates are extracted from the single-exponential correlograms with both nonlinear least-squares fits and second-order cumulant fits. We make several statistical comparisons between the two fitting techniques and verify an earlier result that there is no sample-time dependence in the decay rate errors. We find, however, that the two fitting techniques give decay rates that differ by 1 percent.

Shaumeyer, J. N.↗

Measurement of the temperature coefficient of ratio transformers

We have measured the temperature coefficient of the output of several ratio transformers at ratios near 0.500,000 using an ac bridge and a dual-phase, lock-in amplifier. The two orthogonal output components were each resolved to +/- ppb of the bridge drive signal. The results for three commercial ratio transformers between 20 and 50 C range from 0.5 to 100 ppb/K for the signal component in phase with the bridge drive, and from 4 to 300 ppb/K for the quadrature component.

Briggs, Matthew E.↗

The susceptibility critical exponent for a nonaqueous ionic binary mixture near a consolute point

We report turbidity measurements of a nonaqueous ionic solution of triethyl n-hexylammonium triethyl n-hexylboride in diphenyl ether. A classical susceptibility critical exponent gamma = 1.01 +/- 0.01 is obtained over the reduced temperature range t between values of 0.1 and 0.0001. The best fits of the sample transmission had a standard deviation of 0.39 percent over this range. Ising and spherical model critical exponents are firmly excluded. The correlation length amplitude xi sub 0 from fitting is 1.0 +/- 0.2 nm which is much larger than values found in neutral fluids and some aqueous binary mixtures.

Zhang, Kai C.↗