Report of the EMI Testing of the Johnson Noise Thermometry System

This report summarizes the Electromagnetic Interference (EMI) testing of the Johnson Noise Thermometry System developed at ORNL. The EMI performance is very important for Johnson Noise Thermometry because it requires accurate measurement of a very small noise signal that is amplified 10,000 times. Any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Testing is therefore very important in determining the effects of these external noise sources. Results from testing in several environments with various sources of EMI are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Datasheet Driven Silicon Carbide Power MOSFET Model

A compact model for SiC Power MOSFETs is presented. The model features a physical description of the channel current and internal capacitances and has been validated for dc, CV, and switching characteristics with measured data from a 1200-V, 20-A SiC power MOSFET in a temperature range of 25 degrees C to 225 degrees C. The peculiar variation of on-state resistance with temperature for SiC power MOSFETs has also been demonstrated through measurements and accounted for in the developed model. In order to improve the user experience with the model, a new datasheet driven parameter extraction strategy has been presented which requires only data available in device datasheets, to enable quick parameter extraction for off-the-shelf devices. Excellent agreement is shown between measurement and simulation using the presented model over the entire temperature range.

Mudholkar, M↗

Data Acquisition Backend

This document is intended to summarize the development and testing of the data acquisition module portion of the Johnson Noise Thermometry (JNT) system developed at ORNL. The proposed system has been presented in an earlier report [1]. A more extensive project background including the project rationale is available in the initial project report [2].

97 MATHEMATICS AND COMPUTING↗

Johnson Noise Thermometry for Advanced Small Modular Reactors

Temperature is a key process variable at any nuclear power plant (NPP). The harsh reactor environment causes all sensor properties to drift over time. At the higher temperatures of advanced NPPs the drift occurs more rapidly. The allowable reactor operating temperature must be reduced by the amount of the potential measurement error to assure adequate margin to material damage. Johnson noise is a fundamental expression of temperature and as such is immune to drift in a sensor’s physical condition. In and near the core, only Johnson noise thermometry (JNT) and radiation pyrometry offer the possibility for long-term, high-accuracy temperature measurement due to their fundamental natures. Small Modular Reactors (SMRs) place a higher value on long-term stability in their temperature measurements in that they produce less power per reactor core and thus cannot afford as much instrument recalibration labor as their larger brethren. The purpose of the current ORNL-led project, conducted under the Instrumentation, Controls, and Human-Machine Interface (ICHMI) research pathway of the U.S. Department of Energy (DOE) Advanced SMR Research and Development (R&D) program, is to develop and demonstrate a drift free Johnson noise-based thermometer suitable for deployment near core in advanced SMR plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗