Search NASASearch

Engineering topics

Brockman, M. H.

Publications and source records attributed to Brockman, M. H..

At least 19 records

A carrier-arraying demonstration at Goldstone for receiving Pioneer 11 signals

A carrier arraying technique was demonstrated at Goldstone. The Block III receivers of two 34-m antennas, Deep Space Station 12 and 15, were arrayed together to receive S band (2.3 GHz) signals from the Pioneer 11 spacecraft. Carrier phases in the two receivers were synchronized by the analog phase lock loops, and carrier signals were added at an intermediate frequency to enhance tracking performance. The receiver at DSS 15, which has been unable to lock up and track the Pioneer 11 signal by itself due to a wider tracking loop bandwidth and a higher system temperature, was now able to track the carrier and produce usable baseband signals. The receiver at DSS 12 achieved a reduction of the rms phase error, increasing the telemetry symbol SNR by an average of 0.35 dB. The baseband signals from both antennas were then synchronized and combined using the existing Baseband Assembly, thereby achieving a total symbol SNR increase of 2.5 + or - 0.7 dB relative to DSS 12 alone. A more comprehensive model is presented to permit evaluation of both thermal and phase noise effects. The analysis agrees well with observed data.

Pham, T. T.

Performance characteristics for an array of two receiving systems with unequal predetection signal-to-noise ratios and enhanced radio frequency carrier margin improvement

Enhanced radio frequency carrier margin improvement for arrayed receiving systems for coherent reception of phase modulated signals with residual carrier provides a significant reduction in carrier loop phase noise and increase in signal to noise ratio in the RF carrier tracking loop with an attendant reduction in telemetry radio loss. A significant increase in Doppler frequency rate capability is also realized relative to operating at a narrower tracking loop bandwidth to obtain the same carrier sensitivity improvement. These performance characteristics are examined for an array of two receiving systems with unequal apertures and statistically independent predetection noise.

Brockman, M. H.

Performance characteristics for an array of two receiving systems with equal apertures and enhanced radio frequency carrier margin improvement

Enhanced radio frequency carrier margin improvement for arrayed receiving systems for coherent reception of phase modulated signals with residual carrier provides a significant reduction in carrier loop phase noise and an increase in the signal to noise ratio in the RF carrier tracking loop with an attendant in telemetry radio loss. A significant increase in doppler frequency rate capability is also realized relative to operating at a narrower tracking loop bandwidth to obtain the same carrier sensitivity improvement. These performance characteristics are examined for an array of two receiving sysems with equal apertures and statistically independent prediction noise.

Brockman, M. H.

Radio-Frequency and Wideband Modulation Arraying

Summing network receives coherent signals from all receivers in array. Method sums narrow-band radio-frequency (RF) carrier powers and wide-band spectrum powers of array of separate antenna/receiver systems designed for phase-locked-loop or suppressed-carrier operation.

Brockman, M. H.

Frequency-Diversity Reception for Phase Modulation

Signal-to-noise ratio improved. System receives phase modulation transmitted simultaneously on different carrier frequencies. Used for carriers received through different antennas or through same antenna.

Brockman, M. H.

Enhanced Radio Frequency Carrier Margin Improvements for an Array of Receiving Systems with Unequal Predetection Signal-to-noise Ratios

Enhanced radio frequency carrier margin improvement for arrayed receiving systems for coherent reception which provides a significant carrier sensitivity improvement with a resultant decrease in telemetry radio loss due to reduction in rms phase noise at low carrier margins is discussed. A significant increase in doppler rate capability is realized relative to that obtained by switching to a narrower tracking loop bandwidth to obtain the same carrier sensitivity improvement. The situation for arrayed receiving systems with unequal apertures and statisically independent predetection noise is examined.

Brockman, M. H.

Receiver for Antenna Arrays

Diversity reception system combines narrow-band signals from several antennas to yield amplified demodulated signal. System was developed for spacecraft command signals, which typically have bandwidths of few hundred hertz.

Brockman, M. H.

The effect of partial coherence in receiving system noise temperature on array gain for telemetry and radio frequency carrier reception for receiving systems with unequal predetection signal-to-noise ratios

Signal to noise ratio improvement realized by arraying receiving systems or stations for coherent reception is reduced when some portion of the predetection noise is coherent in the array. This effect for arrayed receiving systems with unequal apertures including expected performance for selected planets of the solar system within the array beamwidth is examined.

Brockman, M. H.

Faraday rotation measurement method and apparatus

A method and device for measuring Faraday rotation of a received RF signal is described. A simultaneous orthogonal polarization receiver compensates for a 3 db loss due to splitting of a received signal into left circular and right circular polarization channels. The compensation is achieved by RF and modulation arraying utilizing a specific receiver array which also detects and measures Faraday rotation in the presence or absence of spin stabilization effects on a linear polarization vector. Either up-link or down-link measurement of Faraday rotation is possible. Specifically, the Faraday measurement apparatus utilized in conjunction with the specific receiver array provides a means for comparing the phase of a reference signal in the receiver array to the phase of a tracking loop signal related to the incoming signal, and comparing the phase of the reference signal to the phase of the tracking signal shifted in phase by 90 degrees. The averaged and unaveraged signals, are compared, the phase changes between the two signals being related to Faraday rotation.

Brockman, M. H.

Receiver array for high-rate telemetry

RF carrier uses two receiver systems to increase signal-to-noise ratio and sensitivity. Signals separately processed are coherently combined at summing junction for improved reception of marginal high-rate signals frequently lost to system, atmosphere, and galactic noises. Two receivers improve ratio by 2.7 dB; improvement is made by arraying more receiver systems.

Brockman, M. H.

Arrayed receivers for low-rate telemetry

RF carrier array includes one master and slave receiving system to improve overall signal-to-noise ratio. Greater number of slave systems creates additional improvement. Scheme reduces detection threshold of low-rate telemetry signals transmitted from spacecraft, enhancing communications efficiency.

Brockman, M. H.

Radio frequency arraying method for receivers

A method and apparatus for increasing the signal to noise ratio of a receiving facility for coherent frequency reception by arraying receiving systems using separate antennas for each, or one antenna for all systems are presented. One system is operated with a carrier tracking loop to provide a first local oscillator frequency for the first and all other systems arrayed, with individual tracking loops in all other systems operated at IF for tracking out any phase differences due to separate group delays using an adjustable phase shifter for a second reference to compensate for different group delays in the antenna and low noise amplifier of each of the other systems. The second IF output of all systems is summed into the first system. This technique may also be used when two systems are arrayed to an antenna designed for circular or linear polarization diversity reception to effectively provide the same signal to noise ratio for both polarized signal transmission channels that would result from matched polarization. An arrangement adapted to high rate telemetry reception is disclosed. With additional components, the same arrangement is adapted to provide low rate telemetry reception as well.

Brockman, M. H.

Radio-frequency carrier arraying for high-rate telemetry reception

A method for increasing the sensitivity for radio frequency reception is described. Receiving systems or stations are arrayed in such a manner as to provide signal to noise ratio improvement relative to a single receiving system or station. Radio frequency carrier arraying for high rate telemetry that provides signal to noise ratio improvement for RF carrier reception and demodulation is discussed.

Brockman, M. H.