Search NASA⌕ Search

Engineering topics

Bromage, J.

Publications and source records attributed to Bromage, J..

36 records · Page 2

Technology development for ultraintense all-OPCPA systems

Optical parametric chirped-pulse amplification (OPCPA) [Dubietis et al. , Opt. Commun. 88 , 437 (1992)] implemented by multikilojoule Nd:glass pump lasers is a promising approach to produce ultraintense pulses ( ${>}10^{23}~\text{W}/\text{cm}^{2}$ ). Technologies are being developed to upgrade the OMEGA EP Laser System with the goal to pump an optical parametric amplifier line (EP OPAL) with two of the OMEGA EP beamlines. The resulting ultraintense pulses (1.5 kJ, 20 fs, $10^{24}~\text{W}/\text{cm}^{2}$ ) would be used jointly with picosecond and nanosecond pulses produced by the other two beamlines. A midscale OPAL pumped by the Multi-Terawatt (MTW) laser is being constructed to produce 7.5-J, 15-fs pulses and demonstrate scalable technologies suitable for the upgrade. MTW OPAL will share a target area with the MTW laser (50 J, 1 to 100 ps), enabling several joint-shot configurations. We report on the status of the MTW OPAL system, and the technology development required for this class of all-OPCPA laser system for ultraintense pulses.

47 OTHER INSTRUMENTATION↗

Simulation of grating compressor misalignment tolerances and mitigation strategies for chirped-pulse–amplification systems of varying bandwidths and beam sizes

Here, the effects of pulse compressor grating misalignment on the pulse duration and focusability are simulated for chirped-pulse–amplification systems of varying bandwidth, beam size, groove density, and incident angle. Tilt-alignment tolerances are specified based on a √2 drop in focused intensity, illustrating how tolerances scale with bandwidth and compressor beam size, which scales with energy when transformed via known grating damage thresholds. Grating-alignment tolerance scaling with grating groove density and incident/diffracted angles is investigated and applied to compressor design. A correlation between grating tip and in-plane rotation error sensitivity is defined and used to compensate residual out-of-plane angular dispersion, even for ultra-broadband pulses. Simulation of dispersion compensation methods after grating misalignment are shown to mitigate pulse lengthening, limited by temporal contrast degradation and higher-order effects for ultrabroad bandwidths.

47 OTHER INSTRUMENTATION↗

Flying focus and its application to plasma-based laser amplifiers

Combining a chirped laser pulse with a chromatic lens yields a flying focus—a laser focus that moves dynamically in time. This provides control over the propagation of the peak laser intensity within an extended focal region that can be many times larger than the system’s Rayleigh length. Any velocity is achievable, including backward relative to the laser propagation direction. Previous simulation results have shown that a laser beam with a flying focus can create a counter-propagating ionization wave and subsequently pump a frequency-downshifted laser via the stimulated Raman scattering instability. Compared to a conventional Raman amplification scheme, several advantages were highlighted, including improved temperature control, plasma uniformity, and precursor growth mitigation. Here, we extend those results to demonstrate additional benefits: (1) the flying focus makes it possible for an unseeded Raman amplifier to produce a short, high-intensity beam; and (2) the flying focus minimizes collisional absorption of the pump, facilitating amplifier operation at higher plasma densities. Preliminary experiments have laid the groundwork for a high-performance plasma-based laser amplifier. The focal spot dynamics were initially confirmed at low intensity. It was subsequently demonstrated that ionization waves of arbitrary velocity can be produced at higher intensity. Here, we show a counter-propagating ionization front moving at approximately the speed of light—the optimal result for a Raman amplifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization Waves of Arbitrary Velocity

The flying focus is a technique in which a chirped laser beam is focused by a chromatic lens to produce an extended focal spot within which laser intensity can propagate at any velocity. If the intensity is above the ionization threshold of a background gas, an ionization wave will track the ionization threshold intensity isosurface as it propagates. We report on the demonstration of such ionization waves of arbitrary velocity. Subluminal and superluminal ionization fronts were produced, both forward- and backward-propagating relative to the ionizing laser. In conclusion, all backward and all superluminal cases mitigated the issue of ionization-induced refraction that typically challenges the formation of long, contiguous plasma channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Record fifth-harmonic-generation efficiency producing 211 nm, joule-level pulses using cesium lithium borate

The fifth harmonic of a pulsed Nd:YLF laser has been realized in a cascade of nonlinear crystals with a record efficiency of 30%. Cesium lithium borate is used in a Type-I configuration for sum-frequency mixing of 1053 nm and 266 nm, producing 211-nm pulses. Flattopped beam profiles and pulse shapes optimize efficiency. Furthermore, energies of the fifth harmonic up to 335 mJ in 2.4 ns pulses were demonstrated.

36 MATERIALS SCIENCE↗

Ionization waves of arbitrary velocity driven by a flying focus

A chirped laser pulse focused by a chromatic lens exhibits a dynamic, or flying, focus in which the trajectory of the peak intensity decouples from the group velocity. In a medium, the flying focus can trigger an ionization front that follows this trajectory. By adjusting the chirp, the ionization front can be made to travel at an arbitrary velocity along the optical axis. For this study, we present analytical calculations and simulations describing the propagation of the flying focus pulse, the self-similar form of its intensity profile, and ionization wave formation. The ability to control the speed of the ionization wave and, in conjunction, mitigate plasma refraction has the potential to advance several laser-based applications, including Raman amplification, photon acceleration, high-order-harmonic generation, and THz generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal effects in an ultrafast BiB 3 O 6 optical parametric oscillator at high average powers

An ultrafast, high-average-power, extended-cavity, femtosecond BiB 3 O 6 optical parametric oscillator was constructed as a test bed for investigating the scalability of infrared parametric devices. Despite the high pulse energies achieved by this system, the reduction in slope efficiency near the maximum-available pump power prompted the investigation of thermal effects in the crystal during operation. Furthermore, the local heating effects in the crystal were used to determine the impact on both phase matching and thermal lensing to understand limitations that must be overcome to achieve microjoule-level pulse energies at high repetition rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-average-power, 2-μm femtosecond optical parametric oscillator synchronously pumped by a thin-disk, mode-locked laser

A high-energy, extended-cavity femtosecond BiBO optical parametric oscillator synchronously pumped by a 1.0-ps, 1030-nm Yb:YAG, thin-disk pump laser is presented. The oscillator operated near degeneracy in a noncollinear interaction geometry, producing signal wavelength tunability from 1.99 to 2.20 μm. The signal pulses have an average power exceeding 2 W, producing 455-fs pulses at 7.08 MHz with energies up to 350 nJ, showing increased potential for tunable sources of scalable ultrafast pulses in the infrared.

36 MATERIALS SCIENCE↗

Talbot-Lau x-ray deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments (invited)

Talbot-Lau X-ray deflectometry (TXD) has been developed as an electron density diagnostic for High Energy Density (HED) plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping were demonstrated for 25–29 J, 8–30 ps laser pulses using copper foil targets. Moiré pattern formation and grating survival were also observed using a copper x-pinch driven at 400 kA, ∼1 kA/ns. These results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Talbot-Lau X-ray Deflectometer electron density diagnostic for laser and pulsed power high energy density plasma experiments

Talbot-Lau X-ray Deflectometry has been developed as an electron density diagnostic for High Energy Density plasmas. The technique can deliver x-ray refraction, attenuation, elemental composition, and scatter information from a single Moiré image. An 8 keV Talbot-Lau interferometer was deployed using laser and x-pinch backlighters. Grating survival and electron density mapping was demonstrated for 25-29 J, 8-30 ps laser pulses using copper foil targets. Moire pattern formation and grating survival was also observed using a copper x-pinch driven at 400 kA, ~1 kA/ns. Lastly, these results demonstrate the potential of TXD as an electron density diagnostic for HED plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An x-ray backlit Talbot-Lau deflectometer for high-energy-density electron density diagnostics

X-ray phase-contrast techniques can measure electron density gradients in high-energy-density plasmas through refraction induced phase shifts. An 8 keV Talbot-Lau interferometer consisting of free standing ultrathin gratings was deployed at an ultra-short, high-intensity laser system using K-shell emission from a 1-30 J, 8 ps laser pulse focused on thin Cu foil targets. Grating survival was demonstrated for 30 J, 8 ps laser pulses. The first x-ray deflectometry images obtained under laser backlighting showed up to 25% image contrast and thus enabled detection of electron areal density gradients with a maximum value of 8.1 ± 0.5 × 10 23 cm ₋3 in a low-Z millimeter sized sample. An electron density profile was obtained from refraction measurements with an error of <8%. We found the 50 ± 15 μm spatial resolution achieved across the full field of view was limited by the x-ray source-size, similar to conventional radiography.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-shot high-resolution characterization of optical pulses by spectral phase diversity

The concept of spectral phase diversity is proposed and applied to the temporal characterization of optical pulses. The experimental trace is composed of the measured power of a plurality of ancillary optical pulses derived from the pulse under test by adding known amounts of chromatic dispersion. The spectral phase of the pulse under test is retrieved by minimizing the error between the experimental trace and a trace calculated from the optical spectrum using the known diagnostic parameters. An assembly composed of splitters and dispersive delay fibers has been used to generate 64 ancillary pulses whose instantaneous power can be detected in a single shot with a high-bandwidth photodiode and oscilloscope. Pulse-shape reconstruction for pulses shorter than the photodetection impulse response has been demonstrated.The diagnostic is experimentally shown to accurately characterize pulses from a chirped-pulse–amplification system when its stretcher is detuned from the position for optimal recompression. As a result, various investigations of the performance with respect to the number of ancillary pulses and the range of chromatic dispersion generated in the diagnostic are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-phase modulation compensation in a regenerative amplifier using cascaded second-order nonlinearities

Self-phase modulation limits the amplification of short optical pulses because of spatial self-focusing and spectral broadening. Cascaded nonlinearities are theoretically and experimentally investigated for intracavity nonlinearity compensation in a neodymium-doped yttrium-lithium-fluoride (Nd:YLF) regenerative amplifier. Experimental results are in good agreement with simulations. Spectral broadening is significantly reduced, allowing for efficient amplification in a Nd:YLF power amplifier.

Dorrer, C.↗

Measuring 8–250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems

Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a more-uniform streak image and enables one to characterize space-charge-induced pulse-broadening effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate target-plane focal-spot characterization in high-energy laser systems using phase retrieval

Target-plane intensities on the short-pulse beamlines of OMEGA EP, a petawatt-class laser, are characterized on-shot using the focal-spot diagnostic (FSD), an indirect wavefront-based measurement. Phaseretrieval methods are employed using on-shot and offline camera-based farfield measurements to improve the wavefront measurements and yield more-accurate, repeatable focal-spot predictions. Incorporation of these techniques has improved the mean cross-correlation between the FSD predictions and direct far-field fluence measurements in the target chamber from 0.78 to 0.94.

Kruschwitz, B. E.↗