An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Correcting Diamagnetic-Loop Measurements for Beam Corkscrew Motion

Diamagnetic loops (DML) are used as a non-invasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. One of the sources of background in these measurements is the flux produced by a straight filamentary current that is offset from the axis and tilted in the plane orthogonal to the offset. This was only a small effect in our experiments, because the beam was steered to be centered on average at the DML. However, we devoted some time to understanding and quantifying the effect, and we recount that effort in this report.

43 PARTICLE ACCELERATORS↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

DARHT-II Beam Position Monitor B-Dot Owner’s Manual

Azimuthal arrays of magnetic and electric field detectors are used to measure the position of the centroid of the DARHT relativistic electron beams. These arrays consist of four detectors with 90-degree azimuthal separation. Differencing the opposing detectors and normalizing to the sum of all four gives the position of the beam, subject to negligibly small errors as discussed in Attachment A. This measurement yields the centroid of the current density, independent of the beam azimuthal asymmetry.

42 ENGINEERING↗

Correcting Magnetic-Field Diffusion Effects in Beam Position Monitors

Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors I: Theory

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results from Diamagnetic Loop Measurements of the DARHT-I Electron Beam [Slides]

Diamagnetic-loop (DML) measurements can inform efforts to improve radiographic resolution. DML is non-invasive, so time-resolved data is available on every shot while tuning or executing a hydrotest. The time-resolved beam size can be deduced from the DML data. LIA beam-transport dynamics affecting beam size can be monitored while testing mitigation measures (e.g., beam halo suppression). Time-resolved beam size at final focus provides immediate information about spot size enlargement due to blur, and effectiveness of mitigation efforts. DML measures magnetic flux produced by a rotating beam, so it also enables monitoring of Larmor emittance that can enlarge the spot size. Beam rotation adds in quadrature with emittance, hence “Larmor emittance." Observing zero bias-field DML flux monitors beam rotation resulting from imperfect nulling of flux linking the cathode, and/or broken LIA transport symmetry (e.g., steering, quads, etc.).

43 PARTICLE ACCELERATORS↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

Beam Position Monitor: Sensors, Calibration and Analysis [Slides]

A beam position monitor (BPM) provides information on electron beam current and position, essential to meeting the performance requirements for the Scorpius accelerator as laid down in FR1.1 –FR1.8 and FR2.2. The critical elements in employing BPM’s to meet those requirements are design of the sensor, design of calibration equipment for the sensor, and design of methods to record and process data.

43 PARTICLE ACCELERATORS↗

A Diamagnetic-Loop-Based Beam Radius Monitor (BRM)

We describe a non-interceptive beam radius monitor that employs a diamagnetic loop. In order to increase the signal strength, the diamagnetic loop radius is considerably smaller than the outer wall radius, the device is placed inside a specially built solenoid magnet to allow independent adjustment of the guide magnetic field strength, and there are two counter-wound diamagnetic loops to double the signal strength and to eliminate common mode signals. This device is calibrated and the magnitude of the electron beam offset/tilt contribution to the measured radius estimated. This device is ready to be validated on an electron induction LINAC such a DARHT-I or DARHT-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D Simulations of Diamagnetic Loop Calibrations

Diamagnetic loops can be used as a non-invasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. A comprehensive theory for interpreting data from a diamagnetic loop relates the rms beam radius to the excluded flux measured by the loop and the beam current. Thus, primary calibration of the loop must relate the loop signal directly to the exclude d flux. We have simulated these calibrations with a 2D field solver in order to identify possible sources of uncertainty in our calibration technique.

43 PARTICLE ACCELERATORS↗