Search NASA⌕ Search

Engineering topics

Brothers, Alan M.

Publications and source records attributed to Brothers, Alan M..

Design and performance measurements of an airborne aerosol backscatter lidar

The global winds measurement application of coherent Doppler lidar requires intensive study of the global climatology of atmospheric aerosol backscatter at infrared wavelengths. An airborne backscatter lidar is discussed, which has been developed to measure atmospheric backscatter profiles at CO2 laser wavelengths. The instrument characteristics and representative flight measurement results are presented.

Menzies, Robert T.↗

Differential absorption lidar signal averaging

This paper presents experimental results using an atmospheric backscatter dual CO2 laser DIAL. It is shown that DIAL signals can be averaged to obtain an N exp -1/2 dependence decrease in the standard deviation of the ratio of backscattered returns from two lasers, where N is the number of DIAL signals averaged, and that such a lidar system can make measurements of gas concentrations with a precision of 0.7 percent in absorptance over 75 m in a short measurement time when the signal strength is high. Factors that eventually limit the rate of improvement in the SNR, such as changes in the ratio of the absorption and/or backscatter at the two laser frequencies and background noise, are discussed. In addition, it is noted that DIAL measurements made using hard-target backscatter often show departures from N exp -1/2 dependence improvement in the standard deviation because they are further limited by the combined effects of atmospheric turbulence and speckle (since the relative reproducibility of the speckle pattern on the receiver gives rise to correlations of the lidar signals).

Grant, William B.↗

CO2 DIAL measurements of water vapor

CO2 lidars have heretofore been used to measure water vapor concentrations primarily using the 10R(20) line at 10.247 microns, which has a strong overlap with a water vapor absorption line. This paper discusses the use of that line as well as other CO2 laser lines for which the absorption coefficients are weaker. The literature on measurement of water vapor absorption coefficients using CO2 lasers is reviewed, and the results from four laboratories are shown to be generally consistent with each other after they are normalized to the same partial pressure, temperature, and ethylene absorption coefficent for the 10P(14) CO2 laser line; however, the agreement with the Air Force Geophysics Laboratory's HITRAN and FASCOD 2 spectral data tapes is not good either for the water vapor absorption lines or for the water vapor continuum. Demonstration measurements of atmospheric water vapor have been conducted using the Mobile Atmospheric Pollutant Mapping System, a dual CO2 lidar system using heterodyne detection. Results are discussed for measurements using three sets of laser line pairs covering a wide range of water vapor partial pressures.

Grant, William B.↗