Search NASA⌕ Search

Engineering topics

Brower, D. L.

Publications and source records attributed to Brower, D. L..

At least 19 records

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Turbulence link to L-mode, I-mode, and H-mode confinement in the DIII-D tokamak

Understanding the physics of low-confinement (L-), improved-confinement (I-), and high-confinement (H-) modes is critical for fusion reactors. The finding herein reports observations of two types of turbulence coexisting near the L-mode edge, one magnetohydrodynamic (MHD)-like and another micro-tearing mode (MTM)-like, linked to the H-mode and I-mode confinement in the DIII-D tokamak. Ion-scale magnetic and density turbulence is measured using a Faraday-effect radial-interferometer-polarimeter and beam-emission-spectroscopy (BES). Broadband turbulence spectra of up to ~600 kHz are observed in two discharges where transitions between L-mode, I-mode, and H-mode occurs. Turbulence is found to be inversely correlated with confinement, meaning lower turbulence power at higher confinement. Distinctively, the high-frequency (HF, >~100 kHz) magnetic turbulence power changes by the most (55%) during transitions primarily involving energy confinement change, whereas the low-frequency (LF, <~100 kHz) magnetic and density turbulence power changes by the most (80%) during transitions primarily involving particle confinement change. The LF turbulence amplitude oscillates with and leads to deuterium-alpha emission oscillations before an H-mode. These results imply that HF turbulence mainly affects energy confinement whereas LF turbulence can affect particle confinement. The magnetic and density turbulence exhibits coherence up to 0.6 and cross-phase magnitude close to π/2 in most cases, suggesting they have a common origin in both the LF and HF ranges. BES suggests that LF turbulence resides at the edge (ρ = 0.95) and HF turbulence can be at the outer core (ρ = 0.8) or edge (ρ = 0.95). Comparisons of measurements, theory, and gyrokinetic simulations suggest that HF turbulence is MTM-like in all cases, whereas LF turbulence is more consistent with MHD-like modes and the exact instability might change during transitions—except that a drift-wave origin is possible in a low collisionality H-mode. These results suggest that the H-mode involves suppressed MHD-like turbulence, whereas the I-mode mitigates MTM-like turbulence along with largely unchanged MHD-like turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Core inductive electric field during sawtooth crashes on DIII-D

Sawtooth crashes on tokamak plasmas exhibit relaxation much faster than resistive time scales via a mechanism not fully understood. Using core magnetic measurements from the Radial Interferometer-Polarimeter (RIP) diagnostic on the DIII-D tokamak, Grad–Shafranov equilibria constrained by internal magnetic measurements that have high time resolution (<1μs) can be computed, allowing analysis of how equilibrium parameters such as safety factor q, current density J, and parallel electric field E ∥ , particularly on-axis, evolve. At the sawtooth crash, on-axis safety factor q 0 is observed to rise by 5% but remain below 1 throughout the cycle, and on-axis current density J 0 is observed to drop by 5%. On-axis parallel electric field E ∥ (0) is found to be balanced by ηJ 0 (resistivity times on-axis current density) except during the 200 µs crash period, where E ∥ (0) reaches 22 V m –1 , exceeding ηJ 0 by a factor of more than 2000. These first measurements in tokamak plasmas verify that generalized Ohm's law is not balanced during the crash by resistive effects alone; this is a finding expected due to the relaxation being much faster than resistive timescales. As a result, measurement of the electric field during the tokamak sawtooth serves to illuminate the physical mechanisms at work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Micro-tearing mode dominated electron heat transport in DIII-D H-mode pedestal

Abstract A new, comprehensive set of evidence reveals that Micro-Tearing Modes (MTMs) dominate pedestal electron heat transport in an H-mode experiment in the DIII-D tokamak. The experiment investigates the role of MTMs by scanning pedestal collisionality, a main drive of MTM instability, from 0.43 to 0.84 on the pedestal top. Broadband (150–800 kHz) magnetic and density fluctuations originating from the pedestal gradient region and highly consistent with MTMs are observed, with amplitude increasing during the scan. The higher magnetic fluctuation amplitude correlates with a lower pedestal electron temperature gradient, implying MTMs may regulate the pedestal electron heat transport. The collisionality scan results in profile and transport changes consistent with predicted transport capability of MTMs: (1) experimentally-determined electron heat diffusivity increases ∼40% at the location where the broadband density fluctuations peak; (2) ion heat diffusivity has less increase (<20%); and (3) a locally flattened region in the electron temperature pedestal is observed at high collisionality. A local, linear gyrokinetic simulation finds MTMs as the most unstable mode in the pedestal gradient region. In addition, local, nonlinear simulations suggest MTMs can dominate and drive experimentally-relevant, megawatt-level electron heat flux. This result establishes MTMs as an effective transport mechanism in the H-mode pedestal, in particular at high collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementing Faraday effect measurement constraints into the Grad–Shafranov equilibrium fitting code EFIT

A new tool for the exploration and diagnosis of the internal magnetic field of plasmas in the DIII-D tokamak in the form of a constraint on the EFIT (Equilibrium Fitting) Grad–Shafranov code based on the Faraday-effect Radial Interferometer-Polarimeter (RIP) diagnostic is presented, including description, verification, and sample application. The physics underlying the diagnostic and its implementation into EFIT are discussed, and the results showing the verification of the model are given, and the model’s limitations are discussed. The influence of the diagnostic’s input on the resulting equilibrium parameters is characterized. Furthermore, the effect of electron density profile refinement is evaluated and found to be negligible. A sample application of the diagnostic is shown, indicating that the RIP constraint has similar effects on the equilibrium as motional Stark effect constraints do.

47 OTHER INSTRUMENTATION↗

Gyrokinetic simulations compared with magnetic fluctuations diagnosed with a Faraday-effect radial interferometer-polarimeter in the DIII-D pedestal

Abstract Experimental data on electromagnetic fluctuations in DIII-D, made available by the Faraday-effect radial interferometer-polarimeter (RIP) diagnostic Chen (2016 Rev. Sci. Instrum. 87 11E108), is examined in comparison with detailed gyrokinetic simulations using gyrokinetic electromagnetic numerical experiment (GENE). The diagnostic has the unique capability of making internal measurements of fluctuating magnetic fields ∫ n e δ B r d R ∫ n e d R . Local linear simulations identify microtearing modes (MTMs) over a substantial range of toroidal mode numbers (peaking at n = 15) with frequencies in good agreement with the experimental data. Local nonlinear simulations reinforce this result by producing a magnetic frequency spectrum in good agreement with that diagnosed by RIP. Simulated heat fluxes are in the range of experimental expectations. However, magnetic fluctuation amplitudes are substantially lower than the experimental expectations. Possible sources of this discrepancy are discussed, notably the fact that the diagnostics are localized at the mid-plane—the poloidal location where the simulations predict the fluctuation amplitudes to be smallest. Despite some discrepancies, several connections between simulations and experiments, combined with general criteria discriminating between potential pedestal instabilities, strongly point to MTMs as the source of the observed magnetic fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-inductive plasma vertical position measurement for the 1056 s discharge on EAST

Vertical position stability plays a crucial role in maintaining safe and reliable plasma operation for long-pulse fusion devices. In general, the vertical position is measured by using inductive magnetic coils installed inside the vacuum vessel; however, the integration drift effects are inherent for steady-state or long-pulse plasma operation. Further, developing a non-magnetic approach provides a fusion reactor-relevant steady-state solution that avoids the negative impact of integration drift. In this paper, we compare the non-inductively determined vertical position achieved by line-integrated interferometer and polarimeter measurements to that employing an inductive flux loop for a 1056 s discharge recently achieved on EAST (Experimental Advanced Superconducting Tokamak). Experimental results show that the non-inductive measurement is more robust than flux loops after 300 s if the integrator is not reset to suppress integrator drift. Real-time vertical position control using the non-inductive system is proposed for the next EAST experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge

Toroidal current profile measurements in the tokamak plasma edge are critical for fusion plasma physics research and model validation. A three-wave Faraday-effect polarimeter-interferometer with a sub-centimeter spatial resolution is proposed on the DIII-D tokamak to determine the edge current profile via Abel inversion. By using probe beams with 316 µm wavelength, a low-field-side, vertical-view, single-pass optical layout covering the plasma edge region (R = 2.15–2.27 m) is assessed. Measurements with no greater than 0.1° polarimetric systematic uncertainty, no greater than 0.01° polarimetric root-mean-square noise (1 kHz bandwidth), and a 0.8 cm radial chord spacing are considered feasible based on the achieved performance of existing systems using similar wavelengths on fusion devices. Furthermore, synthetic diagnostic calculations taking various factors into account, such as diagnostic uncertainty and quality of magnetic flux surfaces, find that the edge current profile can be determined with up to 0.12 MA/m 2 uncertainty, or about 10% of the peak current density in the pedestal of an investigated high-confinement plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System-on-chip integrated circuit technology applications on the DIII-D tokamak for multi-field measurements

Several mm-wave diagnostics on the DIII-D tokamak provide multi-scale and multi-dimensional measurements of plasma profile evolution and turbulence fluctuations. Mm-wave fusion plasma diagnostics that adopt system-on-chip integrated circuit technology can provide better space utilization, flexible installation, and improved sensitivity. In order to further extend this technology for additional fusion facilities with a higher toroidal magnetic field, V-band (55–75 GHz) and F-band (90–140 GHz) chips for Microwave Imaging Reflectometer (MIR) and Electron Cyclotron Emission Imaging (ECEI) instruments are developed and tested in the Davis Millimeter Wave Research Center (DMRC). Current measurement data show that correlation between these SoC-based diagnostic instruments with other state-of-the-art diagnostics enables co-located multi-field turbulence fluctuation measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pedestal magnetic turbulence measurements in ELMy H-mode DIII-D plasmas by Faraday-effect polarimetry

Internal magnetic fluctuation measurements are utilized to identify turbulence associated with micro-tearing modes (MTM) in the DIII-D Edge-Localized-Mode (ELM)-y H-mode pedestal. Using a Faraday-effect polarimeter, magnetic turbulence (150–500 kHz) is directly observed with a typical line-averaged fluctuation amplitude of ~0.8 G at peak frequency (250 kHz) and ~15 G integrated over the spectrum from 150 to 500 kHz. Frequency, poloidal wavenumber, and propagation direction of the magnetic turbulence all serve to identify as MTM. Magnetic turbulence amplitude non-monotonically correlates with collision frequency, peaks off mid-plane, and correlates with electron temperature gradient evolution between ELMs, consistent with MTM features identified from theory and gyro-kinetic simulation. The magnetic turbulence growth correlates with confinement degradation in ELMy H-mode plasmas during a slow density ramp. In conclusion, these internal measurements provide unique constraints toward developing physics understanding and validating models of the H-mode pedestal for future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Internal measurement of magnetic turbulence in ELMy H-mode tokamak plasmas

Magnetic turbulence is directly observed internally in the pedestal of ELMy H-mode tokamak plasmas using a newly developed Faraday-effect polarimetry measurement. Fluctuation amplitude is δb r ≥ 15 G (150–500 kHz), with a ratio of magnetic to density fluctuation |δb r /B|/|δn/n|≥0.15. Here, magnetic turbulence is identified as resulting from micro-tearing-instability and mode growth accompanied by degraded plasma confinement is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of trapped-electron-mode microturbulence in reversed field pinch plasmas

Density fluctuations in the large-density-gradient region of improved confinement Madison Symmetric Torus reversed field pinch (RFP) plasmas exhibit multiple features that are characteristic of the trapped-electron mode (TEM). Core transport in conventional RFP plasmas is governed by magnetic stochasticity stemming from multiple long-wavelength tearing modes. Using inductive current profile control, these tearing modes are reduced, and global confinement is increased to that expected for comparable tokamak plasmas. Under these conditions, new short-wavelength fluctuations distinct from global tearing modes appear in the spectrum at a frequency of f ~ 50 kHz, which have normalized perpendicular wave numbers k ⊥ ρ s ≲0.2 and propagate in the electron diamagnetic drift direction. They exhibit a critical-gradient threshold, and the fluctuation amplitude increases with the local electron density gradient. These characteristics are consistent with predictions from gyrokinetic analysis using the Gene code, including increased TEM turbulence and transport from the interaction of remnant tearing magnetic fluctuations and zonal flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation polarimetry for broadband magnetic fluctuation measurements

Correlation techniques have been successfully utilized for plasma diagnostics like electron cyclotron emission to reduce measurement noise. Herein we present the first application of such a technique to Faraday-effect polarimetry measurements on the Madison Symmetric Torus (MST). The MST far infrared (FIR) interferometer-polarimeter diagnostic utilizes 11 vertical chords with a chord separation of 7-8 cm and a heterodyne detection system for fluctuation measurements up to several hundred kHz. The planar-diode mixers viewing each chord represent independent noise sources; modifying the optical setup so that two different mixers view the same chord allows cross correlation between the two independent signals to reduce the noise floor in fluctuation measurements. In this manner, the noise floor in both interferometry and polarimetry measurements in reversed-field pinch discharges has been reduced by a factor of 20-30. The correlation polarimeter provides a sensitive measurement of broadband magnetic fluctuations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A heterodyne dispersion interferometer for wide bandwidth density measurements on DIII-D

In order to improve both the density and particularly the temporal resolution beyond previous dispersion interferometers (DIs), a heterodyne technique based on an acousto-optic (AO) cell has been added to the DI. A 40 MHz drive frequency for the AO cell allows density fluctuation measurements into the MHz range. A CO 2 laser-based heterodyne DI (HDI) installed on DIII-D has demonstrated that the HDI is capable of tracking the density evolution throughout DIII-D discharges, including disruption events and other rapid transient phenomena. The data also show good agreement with independent density measurements obtained with the existing DIII-D two-color interferometer. The HDI line-integrated density resolution sampled over a 1 s interval is ~9 × 10 17 m -2 . Density fluctuations induced by MHD instabilities are also successfully measured by the HDI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-inductive vertical position measurements by Faraday-effect polarimetry on EAST tokamak

Vertical instability control in an elongated plasma is highly desirable for a tokamak reactor. A multi-channel 694 GHz far-infrared laser-based polarimeter-interferometer system has been used to provide a non-inductive vertical position measurement in the long-pulse EAST tokamak. A detailed comparison of vertical position measurements by polarimetry and external inductive flux loops has been used to validate Faraday-effect polarimetry as an accurate high-time response vertical position sensor.

47 OTHER INSTRUMENTATION↗

Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 μm and 5.22 μm using a CO 2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 μm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. Here, the corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 10 18 m -2 , and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 10 19 Tm -2 . Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D

A Faraday-effect-based radial-interferometer-polarimeter diagnostic has been developed to explore fast magnetic dynamics in high-performance DIII-D plasmas. The instrument measures radial magnetic field perturbations using three chords positioned near the magnetic axis. Newly developed solid-state sources operating at 650 GHz provide phase noise down to 0.01°/$\sqrt{kHz}$ and tunable bandwidth up to 10 MHz. Various systematic errors which can contaminate the polarimetric measurement have been investigated in detail. Distortion of circular polarization due to non-ideal optical components is calibrated using a rotating quarter wave plate technique. The impact of perpendicular magnetic field, i.e., the Cotton-Mouton effect, is evaluated. The error due to non-collinearity of probe beams is minimized to less than 0.5° for electron density up to 7 × 10 19 m -3 by alignment optimization. Optical feedback, due to multiple reflections induced by the double-pass configuration, is identified and reduced. Lastly, coherent and broadband high-frequency magnetic fluctuations for DIII-D H-mode plasmas are observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗