Search NASA⌕ Search

Engineering topics

Brown, C. C.

Publications and source records attributed to Brown, C. C..

Cost minimization of deoxygenation for control of Vampirovibrio chlorellavorus in Chlorella sorokiniana cultures

Deoxygenation is a strategy for preventing Vampirovibrio chlorellavorus infection of Chlorella sorokiniana cultures. Deoxygenation cost was minimized by sparging with nitrogen gas for only one hour at the onset of night and relying on naturally-occurring dark-respiration to maintain low oxygen concentrations throughout the night. This technique substantially reduced V. chlorellavorus infection in laboratory co-cultures. The cost of the approach was evaluated in outdoor experiments with one pure water and one pathogen-free C. sorokiniana culture, grown in a 150-L sealed, vented, translucent-polyethylene reactor. Unlike the small laboratory reactors, which were also sealed and vented, the much larger outdoor reactor maintained the dissolved oxygen concentration in the C. sorokiniana culture at near zero concentration throughout the night cycle. This demonstrates that large covered tanks in commercial applications would keep oxygen concentration near zero for the entire night. The total nitrogen sparged, per night, per liter of algal culture, was determined for the 150-L reactor, and used to estimate the cost per m2 for large scale raceways. Onsite nitrogen generators are the most cost-effective method to supply a high flow of nitrogen gas to commercial scale raceways. The cost of deoxygenation treatment ranged from $16/ton AFDW algae for a shallow (2 cm) gravity flow system with 75% harvest prior to deoxygenation to over $1,300/ton for a 20 cm depth raceway with plastic tanks.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing Photometric Flicker

The focus of this study is simply to report on the commercial availability and performance of emerging flicker meters. Commercial-meter measurements and calculations were compared against those generated by a photoelectric characterization system developed by the Pacific Northwest National Laboratory (PNNL). The results and analysis show that the three commercially available flicker meters evaluated for this study measured light-intensity waveforms and calculated essential flicker-performance characteristics and metrics similarly, both to each other and to the reference meter chosen as an accuracy benchmark. Some differences in performance were found, however, when measurements were taken of light-intensity waveforms with significant high-frequency content – greater than the dominant 120 Hz found in many products at full output. Such conditions may be found in light sources that employ pulse-width modulation to achieve their target light output (e.g., intensity or color). If the meter was not appropriately configured (e.g., sampling frequency was too low), or if proper configuration was not possible given meter constraints (e.g., maximum number of available data points), then the waveform characteristics were not accurately captured, often resulting in the calculation of flicker metrics that deviated significantly from the reference.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗