A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

X-ray transport and radiation response assessment (XTRRA) experiments at the National Ignition Facility

Our team has developed an experimental platform to evaluate the x-ray-generated stress and impulse in materials. Experimental activities include x-ray source development, design of the sample mounting hardware and sensors interfaced to the National Ignition Facility’s diagnostics insertion system, and system integration into the facility. This paper focuses on the X-ray Transport and Radiation Response Assessment (XTRRA) test cassettes built for these experiments. The test cassette is designed to position six samples at three predetermined distances from the source, each known to within ±1% accuracy. Built-in calorimeters give in situ measurements of the x-ray environment along the sample lines of sight. The measured accuracy of sample responses as well as planned modifications to the XTRRA cassette is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging

We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. Furthermore, we have developed a device that can be added to the framing camera head to prevent these artifacts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A geophysical shock and air blast simulator at the National Ignition Facility

The energy partitioning energy coupling experiments at the National Ignition Facility (NIF) have been designed to measure simultaneously the coupling of energy from a laser-driven target into both ground shock and air blast overpressure to nearby media. The source target for the experiment is positioned at a known height above the ground-surface simulant and is heated by four beams from the NIF. The resulting target energy density and specific energy are equal to those of a low-yield nuclear device. The ground-shock stress waves and atmospheric overpressure waveforms that result in our test system are hydrodynamically scaled analogs of full-scale seismic and air blast phenomena. This report summarizes the development of the platform, the simulations, and calculations that underpin the physics measurements that are being made, and finally the data that were measured. Agreement between the data and simulation of the order of a factor of two to three is seen for air blast quantities such as peak overpressure. Historical underground test data for seismic phenomena measured sensor displacements; we measure the stresses generated in our ground-surrogate medium. We find factors-of-a-few agreement between our measured peak stresses and predictions with modern geophysical computer codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the Energy Partitioning Energy Coupling (EPEC) NIF Experiment

Using scaled experiments performed at the National Ignition Facility (NIF), the Energy Partitioning Energy Coupling (EPEC) experimental platform will provide benchmark data from scaled high energy density (HED) environments to validate codes for prompt yield determination following a near surface explosion. A set of numerical codes has been used to design the experiment and predict the experimental results. Preliminary NIF shots assessing performance of the EPEC energy source (a halfraum) have been carried out. Modeling of the EPEC experiments is discussed, with comparisons to results from the source shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ANOPP programmer's reference manual for the executive System

Documentation for the Aircraft Noise Prediction Program as of release level 01/00/00 is presented in a manual designed for programmers having a need for understanding the internal design and logical concepts of the executive system software. Emphasis is placed on providing sufficient information to modify the system for enhancements or error correction. The ANOPP executive system includes software related to operating system interface, executive control, and data base management for the Aircraft Noise Prediction Program. It is written in Fortran IV for use on CDC Cyber series of computers.

Gillian, R. E.↗

Program for the analysis of time series

A digital computer program for the Fourier analysis of discrete time data is described. The program was designed to handle multiple channels of digitized data on general purpose computer systems. It is written, primarily, in a version of FORTRAN 2 currently in use on CDC 6000 series computers. Some small portions are written in CDC COMPASS, an assembler level code. However, functional descriptions of these portions are provided so that the program may be adapted for use on any facility possessing a FORTRAN compiler and random-access capability. Properly formatted digital data are windowed and analyzed by means of a fast Fourier transform algorithm to generate the following functions: (1) auto and/or cross power spectra, (2) autocorrelations and/or cross correlations, (3) Fourier coefficients, (4) coherence functions, (5) transfer functions, and (6) histograms.

Brown, T. J.↗

Effect of advanced aircraft noise reduction technology on the 1990 projected noise environment around Patrick Henry Airport

A study has been conducted of the future noise environment of Patric Henry Airport and its neighboring communities projected for the year 1990. An assessment was made of the impact of advanced noise reduction technologies which are currently being considered. These advanced technologies include a two-segment landing approach procedure and aircraft hardware modifications or retrofits which would add sound absorbent material in the nacelles of the engines or which would replace the present two- and three-stage fans with a single-stage fan of larger diameter. Noise Exposure Forecast (NEF) contours were computed for the baseline (nonretrofitted) aircraft for the projected traffic volume and fleet mix for the year 1990. These NEF contours are presented along with contours for a variety of retrofit options. Comparisons of the baseline with the noise reduction options are given in terms of total land area exposed to 30 and 40 NEF levels. Results are also presented of the effects on noise exposure area of the total number of daily operations.

Cawthorn, J. M.↗