Search NASASearch

Engineering topics

Brown, D. M.

Publications and source records attributed to Brown, D. M..

The charge injection device /CID/ as a stellar tracking sensor

A 128 x 128 element CID imager was operated in a simulated stellar trackling environment and evaluated for temporal and pattern noise and spectral response over a temperature range of -40 C to +25 C. The test devices were fabricated on long-lifetime bulk silicon material and utilized very thin upper-level polysilicon electrodes for enhanced spectral response. A standard microcomputer was used to generate all control signals and to collect and process performance data. The results of this program were used to predict the performance of a 400 x 400 CID array designed specifically for stellar-tracking.

Burke, H. K.

Cost benefit analysis of the transfer of NASA remote sensing technology to the state of Georgia

The author has identified the following significant results. First order benefits can generally be quantified, thus allowing quantitative comparisons of candidate land cover data systems. A meaningful dollar evaluation of LANDSAT can be made by a cost comparison with equally effective data systems. Users of LANDSAT data can be usefully categorized as performing three general functions: planning, permitting, and enforcing. The value of LANDSAT data to the State of Georgia is most sensitive to the parameters: discount rate, digitization cost, and photo acquisition cost. Under a constrained budget, LANDSAT could provide digitized land cover information roughly seven times more frequently than could otherwise be obtained. Thus on one hand, while the services derived from LANDSAT data in comparison to the baseline system has a positive net present value, on the other hand if the budget were constrained, more frequent information could be provided using the LANDSAT system than otherwise be obtained.

Zimmer, R. P.

Recent developments in CID imaging

Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.

Michon, G. J.