Search NASA⌕ Search

Engineering topics

Brown, J. A.

Publications and source records attributed to Brown, J. A..

At least 19 records

C 12 ( n , n 1 ′ γ ) partial γ -ray cross section measured using the GENESIS array

Improved neutron inelastic scattering cross sections have repeatedly been identified as a top priority nuclear data need, important for basic science and a range of applications in nuclear energy, stockpile stewardship, and proliferation detection. For the C 12 ( n , n ′ γ ) reaction in particular, recent measurements have unveiled some structural discrepancies, demonstrating incongruities among themselves and in relation to the ENDF/B-VIII.0 nuclear data evaluation. To help resolve these disagreements, a measurement was performed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory using a broad-spectrum neutron beam and a 99.8% pure natural carbon target. The Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was employed to measure energy-differential γ -ray emission spectra as a function of incident neutron energy in the energy range of 5.5 to 16.7 MeV. The C 12 partial γ -ray cross sections were extracted at 63 ∘ , 122 . 5 ∘ , and 150 ∘ with respect to the incoming neutron beam and integrated using angular distribution data available in the literature. The data show agreement with a recent literature measurement and evaluation from 11 to 15 MeV, but indicate a larger cross section for incident neutron energies between 5.5 and 8.5 MeV. The measured relative angular distributions are also reported and were found to agree with evaluation. Published by the American Physical Society 2025

Gordon, J. M. (ORCID:0009000789886897)↗

Measurement of the energy-differential 35 Cl( n, p 0 ) 35 S cross section via the ratio with 6 Li( n, α ) 3 H

Knowledge of the neutron-induced 35 Cl ⁢(n, x) cross sections is vital to the design and certification of molten chloride fast reactors (MCFRs) since the 35 Cl (n, p 0 ) 35 S reaction is believed to be a significant reactor poison. However, recently published measurements are inconsistent with each other and with evaluation. Here, the goal of this work is to measure the 35 Cl (n, p 0 ) reaction cross section using a technique that is different from recent measurements. The experiment was conducted at Lawrence Berkeley National Laboratory's (LBNL) 88-Inch Cyclotron using thick target deuteron breakup from a 14 MeV deuteron beam. Energy-differential 35 Cl (n, p 0 ) 35 S cross sections were obtained via ratio with the 6 Li (n, a)⁢ 3 H reaction using an active target experiment with a Cs 2 ⁢LiYCl 6 (CLYC) scintillator. The 35 Cl (n, p 0 ) reaction cross section was measured from 2.02 to 7.46 MeV. The results are consistent with Kuvin et al., confirming a roughly 50% reduction in magnitude relative to the ENDF/B-VIII.0 evaluation. These data provide new insight into the role of natural Cl as an MCFR poison. The reduction of the 35 Cl (n, p 0 ) reaction cross section compared to evaluation suggests that MCFR criticality is less sensitive to Cl enrichment. This may in turn reduce building and operating costs since isotope separation may not be needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PANDA-FES: Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science

Nuclear fusion is a potential source of carbon-free electricity with many concepts in development. The Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science (PANDA-FES) suite has been deployed since 2021 to measure neutron yield, energy, and spatiotemporal source location at two different Z-pinch fusion devices. This diagnostic can be used at a variety of facilities pursuing fusion in the magnetic, inertial, and magneto-inertial regimes. These different regimes have a wide range of time scales from less than 100 ns to a few μ s, neutron yields from 10 6 to 10 11 , and noise environments. Neutron yield is measured through activation of 79 Br and 89 Y with calibrated detectors. Temporal, spatial, and energy dependence of neutrons is measured with scintillators coupled to photomultiplier tubes (PMTs). Experimental setups and data analysis methods have been developed for these conditions. Finally, neutron yield, neutron energy anisotropy, and spatiotemporal evolution of the source have been measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute light yield of the EJ-204 plastic scintillator

The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the absolute light yield of organic scintillators are limited. The goal of this work is to assess the suitability of the EJ-204 plastic scintillator from Eljen Technology to serve as a reference standard for measurements of the absolute light yield of organic scintillators. Four EJ-204 samples were examined: two manufactured approximately four months prior and stored in high-purity nitrogen, and two aged approximately eleven years and stored in ambient air. The scintillator response was measured using a large-area avalanche photodiode calibrated using low energy $γ$-ray and X-ray sources. The product of the quantum efficiency of the photodetector and light collection efficiency of the housing was characterized using an experimentally-benchmarked optical photon simulation. The average absolute light yield of the fresh samples, 9100 ± 400 photons per MeV, is lower than the manufacturer-reported value of 10400 photons per MeV. Moreover, the aged samples demonstrated significantly lower light yields, deviating from the manufacturer specification by as much as 26%. These results are consistent with recent work showcasing environmental aging in plastic scintillators and suggest that experimenters should use caution when deploying plastic scintillators in photon counting applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of proton light yield of water-based liquid scintillator

Abstract The proton light yield of liquid scintillators is an important property in the context of their use in large-scale neutrino experiments, with direct implications for neutrino-proton scattering measurements and the discrimination of fast neutrons from inverse $$\beta $$ β -decay coincidence signals. This work presents the first measurement of the proton light yield of a water-based liquid scintillator (WbLS) formulated from 5% linear alkyl benzene (LAB), at energies below 20 MeV, as well as a measurement of the proton light yield of a pure LAB + 2 g/L 2,5-diphenyloxazole (PPO) mixture (LABPPO). The measurements were performed using a double time-of-flight method and a pulsed neutron beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. The proton light yields were measured relative to that of a 477 keV electron. The relative proton light yield of WbLS was approximately 3.8% lower than that of LABPPO, itself exhibiting a relative proton light yield 15–20% higher than previous measurements of an analogous anoxic sample. The observed quenching is not compatible with the Birks model for either material, but is well described with the addition of Chou’s bimolecular quenching term.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 40 Ar(d,p) 41 Ar cross section between 3–7 MeV

To determine the safety of using argon as a deuteron beam stopping material, the 40 Ar(d,p) 41 Ar cross section was measured at average deuteron energies of 3.6 MeV, 5.5 MeV, and 7.0 MeV using an activation method. A 16-MeV deuteron beam produced by Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron was degraded to each energy by nickel foils and the front wall of an aluminum gas chamber. The reduced-energy deuterons were used to activate a sample of nat Ar gas. After each irradiation, the gas chamber’s 41 Ar activation was measured with a high-purity germanium detector. The cross sections measured were larger than a previous measurement by ~40%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Performance evaluation of an energy tuning assembly for neutron spectral shaping

An energy tuning assembly (ETA) was designed here to be fielded at the National Ignition Facility (NIF) to modify the characteristic D-T fusion spectrum to include a prompt fission neutron spectral component. The ETA was characterized at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory to measure the shaped spectrum from an incident deuteron breakup neutron source, test the proposed neutron spectroscopy techniques used to inform the flux measurements at NIF, and validate the ability to predict ETA performance using a Monte Carlo Neutral Particle (MCNP) simulation. Activation foils (i.e., Ni, In, Au, Al) were exposed to a collimated 33-MeV deuteron-breakup beam originating from a tantalum breakup target. The source spectrum absent the ETA was characterized using a set of activation foils and the STAYSL unfolding code. Finally, the ETA-modified spectrum was obtained using activation foil unfolding with a χ 2 ν = 0 . 92 . The ETA-modified unfolded spectrum agreed with the MCNP-simulated prediction in the energy range of 0.1–14 MeV, but exhibited disagreements in the 10 eV–100 keV region. This work demonstrates shaping of the NIF neutron spectrum via the ETA to be a viable path forward for tailored neutron beams at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low energy light yield of fast plastic scintillators

Compact neutron imagers using double-scatter kinematic reconstruction are being designed for localization and characterization of special nuclear material. These neutron imaging systems rely on scintillators with a rapid prompt temporal response as the detection medium. As n-p elastic scattering is the primary mechanism for light generation by fast neutron interactions in organic scintillators, proton light yield data are needed for accurate assessment of scintillator performance. The proton light yield of a series of commercial fast plastic organic scintillators—EJ-200, EJ-204, and EJ-208—was measured via a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable deuteron breakup neutron source, target scintillators housed in a dual photomultiplier tube configuration, and an array of pulse-shape- discriminating observation scintillators, the fast plastic scintillator light yield was measured over a broad and continuous energy range down to proton recoil energies of approximately 50 keV. Furthermore, this work provides key input to event reconstruction algorithms required for utilization of these materials in emerging neutron imaging modalities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton light yield in organic scintillators using a double time-of-flight technique

Recent progress in the development of novel organic scintillators necessitates modern characterization capabilities. As the primary means of energy deposition by neutrons in these materials is n-p elastic scattering, knowledge of the proton light yield is paramount. This work establishes a new model-independent method to continuously measure the proton light yield in organic scintillators over a broad energy range. Using a deuteron breakup neutron source at the 88-in. Cyclotron at Lawrence Berkeley National Laboratory and an array of organic scintillators, the proton light yield of EJ-301 and EJ-309, commercially available organic liquid scintillators from Eljen Technology, was measured via a double time-of-flight technique. The light yield was determined using a kinematically over-constrained system in the proton energy range of 1–20 MeV. The effect of the pulse integration length on the magnitude and shape of the proton light yield relation was also explored. In conclusion, this work enables accurate simulation of the performance of advanced neutron detectors and supports the development of next-generation neutron imaging systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multiscale study of damage in elastomeric syntactic foams

Damage mechanisms in elastomeric syntactic foams filled with glass microballoons (GMB) and resulting effects on the macroscale elastic constants have been investigated. Direct numerical simulations of the material microstructure, composite theory analyses, and uniaxial compression tests across a range of filler volume fractions were conducted. The room temperature and elastic behavior of composites with undamaged, fully debonded, and fully crushed GMBs were investigated for syntactic foams with a polydimethylsiloxane matrix. Good agreement was obtained between numerical studies, composite theory, and experiments. Debonding was studied via finite element models due to the difficulty of isolating this damage mechanism experimentally. The predictions indicate that the bulk modulus is insensitive to the state of debonding at low-GMB-volume fractions but is dramatically reduced if GMBs are crushed. The shear behavior is affected by both debonding and crush damage mechanisms. The acute sensitivity of the bulk modulus to crushed GMBs is further studied in simulations in which only a fraction of GMBs are crushed. We find that the composite bulk modulus drops severely even when just a small fraction of GMBs are crushed. Various material parameters such as GMB wall thickness, volume fraction, and minimum balloon spacing are also investigated, and they show that the results presented here are general and apply to a wide range of microstructure and GMB filler properties.

36 MATERIALS SCIENCE↗

FIER: Software for analytical modeling of delayed gamma-ray spectra

We report a new software package, the Fission Induced Electromagnetic Response (FIER) code, has been developed to analytically predict delayed γ-ray spectra following fission. FIER uses evaluated nuclear data and solutions to the Bateman equations to calculate the time-dependent populations of fission products and their decay daughters resulting from irradiation of a fissionable isotope. These populations are then used in the calculation of γ-ray emission rates to obtain the corresponding delayed γ-ray spectra. FIER output was compared to experimental data obtained by irradiation of a 235 U sample in the Godiva critical assembly. This investigation illuminated discrepancies in the input nuclear data libraries, showcasing the usefulness of FIER as a tool to address nuclear data deficiencies through comparison with experimental data. Finally, FIER provides traceability between γ-ray emissions and their contributing nuclear species, decay chains, and parent fission fragments, yielding a new capability for the nuclear science community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron spectroscopy for pulsed beams with frame overlap using a double time-of-flight technique

A new double time-of- ight (dTOF) neutron spectroscopy technique has been developed for pulsed broad spectrum sources with a duty cycle that results in frame overlap, where fast neutrons from a given pulse overtake slower neutrons from previous pulses. Using a tunable beam at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory, neutrons were produced via thick-target breakup of 16 MeV deuterons on a beryllium target in the cyclotron vault. The breakup spectral shape was deduced from a dTOF measurement using an array of EJ-309 organic liquid scintillators. Simulation of the neutron detection efficiency of the scintillator array was performed using both GEANT4 and MCNP6. The efficiency- corrected spectral shape was normalized using a foil activation technique to obtain the energy-dependent flux of the neutron beam at zero degrees with respect to the incoming deuteron beam. The dTOF neutron spectrum was compared to spectra obtained using HEPROW and GRAVEL pulse height spectrum unfolding techniques. While the unfolding and dTOF results exhibit some discrepancies in shape, the integrated flux values agree within two standard deviations. As a result, this method obviates neutron time-of-flight spectroscopy challenges posed by pulsed beams

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

43 PARTICLE ACCELERATORS↗