Search NASA⌕ Search

Engineering topics

Brown, S.

Publications and source records attributed to Brown, S..

At least 19 records

Using in-situ strain measurements to evaluate the accuracy of stress estimation procedures from fracture injection/shut-in tests

Fracture injection/shut-in tests are commonly used to measure the state of stress. Injection creates a hydraulic fracture (or in some cases, opens a preexisting fracture), and then the pressure after shut-in is monitored to identify fracture closure. Different interpretation procedures have been proposed for estimating closure, and the procedures sometimes yield significantly different results. In this study, direct, in-situ strain measurements are used to observe fracture reopening and closure. The tests were performed as part of the EGS Collab project, a mesoscale project performed at 1.25 and 1.5 km depth at the Sanford Underground Research Facility. The tests were instrumented with the SIMFIP tool, a double-packer probe with a high-resolution three-dimensional borehole displacement sensor. The measurements provide a direct observation of the fracture closure signature, enabling a high-fidelity estimate of the fracture closure stress (ie, the normal stress on the fracture). In two of the four tests, injection created an opening mode fracture, and so the closure stress can be interpreted as the minimum principal stress. In the other two tests, injection probably opened preexisting natural fractures, and so the closure stress can be interpreted as the normal stress on the fractures. The strain measurements are compared against different proposed methods for estimating closure stress from pressure transients. The shut-in transients are analyzed with two techniques that are widely used in the field of petroleum engineering – the ‘tangent’ method and the ‘compliance’ method. In three of the four tests, the tangent method significantly underestimates the closure stress. The compliance method is reasonably accurate in all four tests. Closure stress is also interpreted using two other commonly-used methods – ‘first deviation from linearity’ and the method of Hayashi and Haimson. In comparison with the SIMFIP data, these methods tend to overestimate the closure stress, evidently because they identify closure from early-time transient effects, such as near-wellbore tortuosity. In two of the tests, microseismic imaging provides an independent estimate of the size of the fracture created by injection. When combined with a simple mass balance calculation, the SIMFIP stress measurements yield predictions of fracture size that are reasonably consistent with the estimates from microseismic. In conclusion, the calculations imply an apparent fracture toughness 2-3x higher than typical laboratory-derived values.

58 GEOSCIENCES↗

First observation of isolated nuclear recoils following neutron capture for dark matter calibration

Low-energy nuclear recoils (NRs) are hard to measure, because they produce few e - /h + pairs in solids—i.e., they have low “ionization yield.” A silicon detector was exposed to thermal neutrons over 2.5 live days, probing NRs down to 450 eV. The observation of a neutron capture-induced component of NRs at low energies is supported by the much-improved fit upon inclusion of a capture NR model. This result shows that thermal neutron calibration of very low recoil energy NRs is promising for dark matter searches, coherent neutrino experiments, and improving understanding of ionization dynamics in solids.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring the structure and equation of state of polyethylene terephthalate at megabar pressures

Abstract We present structure and equation of state (EOS) measurements of biaxially orientated polyethylene terephthalate (PET, $$({\hbox {C}}_{10} {\hbox {H}}_8 {\hbox {O}}_4)_n$$ ( C 10 H 8 O 4 ) n , also called mylar) shock-compressed to ( $$155 \pm 20$$ 155 ± 20 ) GPa and ( $$6000 \pm 1000$$ 6000 ± 1000 ) K using in situ X-ray diffraction, Doppler velocimetry, and optical pyrometry. Comparing to density functional theory molecular dynamics (DFT-MD) simulations, we find a highly correlated liquid at conditions differing from predictions by some equations of state tables, which underlines the influence of complex chemical interactions in this regime. EOS calculations from ab initio DFT-MD simulations and shock Hugoniot measurements of density, pressure and temperature confirm the discrepancy to these tables and present an experimentally benchmarked correction to the description of PET as an exemplary material to represent the mixture of light elements at planetary interior conditions.

36 MATERIALS SCIENCE↗

Status of Remote Sensing of Salinity by Aquarius

Aquarius is an L-band instrument designed to measure sea surface salinity from space. The instrument was launched in 2011 and data acquisition ended in June 2015 when control of the spacecraft was lost. Aquarius produced global maps of salinity with accuracy of 0.2 psu (Practical Salinity Unit) and special resolution of 150 kilometers as well as other products such as global maps of RFI (Radio Frequency Interference) and soil moisture. The mission will formally end December 2017.

Le Vine, D. M.↗

Assessment of Current Global and Regional Mean Sea Level Estimates Based on the TOPEX/Poseidon Jason-1 and 2 Climate Data Record

Recent developments in Precise Orbit Determinations (POD) due to in particular to revisions to the terrestrial reference frame realization and the time variable gravity (TVG) continues to provide improvements to the accuracy and stability of the PO directly affecting mean sea level (MSL) estimates. Long-term credible MSL estimates require the development and continued maintenance of a stable reference frame, along with vigilant monitoring of the performance of the independent tracking systems used to calculate the orbits for altimeter spacecrafts. The stringent MSL accuracy requirements of a few tenths of an mm/yr are particularly essential for mass budget closure analysis over the relative short time period of Jason-l &2, GRACE, and Argo coincident measurements. In an effort to adhere to cross mission consistency, we have generated a full time series of experimental orbits (GSFC stdlllO) for TOPEX/Poseidon (TP), Jason-I, and OSTM based on an improved terrestrial reference frame (TRF) realization (ITRF2008), revised static (GGM03s), and time variable gravity field (Eigen6s). In this presentation we assess the impact of the revised precision orbits on inter-mission bias estimates, and resultant global and regional MSL trends. Tide gauge verification results are shown to assess the current stability of the Jason-2 sea surface height time series that suggests a possible discontinuity initiated in early 2010. Although the Jason-2 time series is relatively short (approximately 3 years), a thorough review of the entire suite of geophysical and environmental range corrections is warranted and is underway to maintain the fidelity of the record.

Beckley, B. D.↗

Receivers for the Microwave Radiometer on Juno

Six receivers for the MicroWave Radiometer (MWR) are currently under development at JPL. These receivers cover a frequency range of 0.6 to 22 GHz in approximately octave steps, with 4 % bandwidth. For calibration and diagnosis three noise diodes and a Dicke switch are integrated into each receiver. Each receiver is connected to its own antenna which is mounted with its bore sights perpendicular to the spin axis of the spacecraft. As the spacecraft spins at 2 RPM, the antenna field of view scans Jupiter's atmosphere from limb to nadir to limb, measuring microwave emission down to 1000-bar.

microwaves↗

Microwave Radiometers from 0.6 to 22 GHz for Juno, a Polar Orbiter around Jupiter

A compact radiometer instrument is under development at JPL for Juno, the next NASA New Frontiers mission, scheduled to launch in 2011. This instrument is called the MWR (MicroWave Radiometer), and its purpose is to measure the thermal emission from Jupiter's atmosphere at selected frequencies from 0.6 to 22 GHz. The objective is to measure the distributions and abundances of water and ammonia in Jupiter's atmosphere, with the goal of understanding the previously unobserved dynamics of the subcloud atmosphere, and to discriminate among models for planetary formation in our solar system. The MWR instrument is currently being developed to address these science questions for the Juno mission. As part of a deep space mission aboard a solar-powered spacecraft, MWR is designed to be compact, lightweight, and low power. The entire MWR instrument consists of six individual radiometer channels with approximately 4% bandwidth at 0.6, 1.25,2.6,5.2, 10,22 GHz operating in direct detection mode. Each radiometer channel has up to 80 dB of gain with a noise figure of several dB. The highest frequency channel uses a corrugated feedhorn and waveguide transmission lines, whereas all other channels use highly phase stable coaxial cables and either patch array or waveguide slot array antennas. Slot waveguide array antennas were chosen for the low loss at the next three highest frequencies and patch array antennas were implemented due to the mass constraint at the two lowest frequencies. The six radiometer channels receive their voltage supplies and control lines from an electronics unit that also provides the instrument communication interface to the Juno spacecraft. For calibration purposes each receiver has integrated noise diodes, a Dicke switch, and temperature sensors near each component that contributes to the noise figure. In addition, multiple sensors will be placed along the RF transmission lines and the antennas in order to measure temperature gradients. All antennas and RF transmission lines must withstand low temperatures and the harsh radiation environment surrounding Jupiter; the receivers and control electronics are protected by a radiation-shielding enclosure on the Juno spacecraft that also provides for a benign and stable operating temperature environment. This paper will focus on the concept of the MWR instrument and will present results of one breadboard receiver channel.

receiver↗

Microwave Radiometers from 0.6 to 22 GHz for Juno, a Polar Orbiter around Jupiter

A compact instrument called the MWR (microwave radiometer) is under development at JPL for Juno, the next NASA new frontiers mission, scheduled to launch in 2011. It's purpose is to measure the thermal emission from Jupiter's atmosphere at six selected frequencies from 0.6 to 22 GHz, operating in direct detection mode, in order to quantify the distributions and abundances of water and ammonia in Jupiter's atmosphere. The goal is to understand the previously unobserved dynamics of the sub-cloud atmosphere, and to discriminate among models for planetary formation in our solar system. as part of a deep space mission aboard a solar-powered spacecraft, MWR is designed to be compact, lightweight, and low power. The receivers and control electronics are protected by a radiation-shielding enclosure on the Juno spacecraft that also provides for a benign and stable operating temperature environment. All antennas and RF transmission lines outside the vault must withstand low temperatures and the harsh radiation environment surrounding Jupiter. This paper describes the concept of the MWR instrument and presents results of one breadboard receiver channel.

Jupiter↗

Microwave Radiometers from 0.6 to 22 GHz for Juno, A Polar Orbiter Around Jupiter

A compact instrument called the MWR (MicroWave Radiometer) is under development at JPL for Juno, the next NASA New Frontiers mission, scheduled to launch in 2011. It's purpose is to measure the thermal emission from Jupiter's atmosphere at six selected frequencies from 0.6 to 22 GHz, operating in direct detection mode, in order to quantify the distributions and abundances of water and ammonia in Jupiter's atmosphere. The goal is to understand the previously unobserved dynamics of the sub-cloud atmosphere, and to discriminate among models for planetary formation in our solar system. As part of a deep space mission aboard a solar-powered spacecraft, MWR is designed to be compact, lightweight, and low power. The receivers and control electronics are protected by a radiation-shielding enclosure on the Juno spacecraft that would provide a benign and stable operating temperature environment. All antennas and RF transmission lines outside the vault must withstand low temperatures and the harsh radiation environment surrounding Jupiter. This paper describes the concept of the MWR instrument and presents results of one breadboard receiver channel.

Antenna↗

SiC As An Energetic Particle Detector

Several new technologies have been introduced recently in the region of semiconductor material for solid state detectors (SSD). Of particular interest is silicon carbide (SIC) since its band gap is larger than that of pure silicon, reducing its dark current and making SIC capable of operating at high temperatures and more tolerant of radiation damage. But the trade off is that a higher band gap also means fewer electron hole pairs generated, and thus a smaller signal, for detecting incident radiation. To determine what the lower limit of SiC detectors to energetic particles is, we irradiated a SiC diode with particles ranging in energy from 50 keV to 1.6 MeV and masses from 1 to 16 amu. We found that the SiC detectors sensitivity was comparable to that of pure silicon, with the SiC detector being able to measure particles down to 50 keV/amu and possibly lower.

Yan, F.↗

The Spatial Distribution of Forest Biomass in the Brazilian Amazon: A Comparison of Estimates

The amount of carbon released to the atmosphere as a result of deforestation is determined, in part, by the amount of carbon held in the biomass of the forests converted to other uses. Uncertainty in forest biomass is responsible for much of the uncertainty in current estimates of the flux of carbon from land-use change. We compared several estimates of forest biomass for the Brazilian Amazon, based on spatial interpolations of direct measurements, relationships to climatic variables, and remote sensing data. We asked three questions. First, do the methods yield similar estimates? Second, do they yield similar spatial patterns of distribution of biomass? And, third, what factors need most attention if we are to predict more accurately the distribution of forest biomass over large areas? Amazonian forests (including dead and below-ground biomass) vary by more than a factor of two, from a low of 39 PgC to a high of 93 PgC. Furthermore, the estimates disagree as to the regions of high and low biomass. The lack of agreement among estimates confirms the need for reliable determination of aboveground biomass over large areas. Potential methods include direct measurement of biomass through forest inventories with improved allometric regression equations, dynamic modeling of forest recovery following observed stand-replacing disturbances (the approach used in this research), and estimation of aboveground biomass from airborne or satellite-based instruments sensitive to the vertical structure plant canopies.

Houghton, R. A.↗

[Evaluation of super dwarf wheat growth and development in greenhouse "Svet" during cultivation in inhabited pressurized chamber]

Goals of the 3-month experiment GREENHOUSE using the equipment of greenhouse SVET (ECO-PSY-95) were to feature growth and development of wheat through the entire cycle of ontogeny under the maximally mimicked MIR environment, and to try out the procedures and timeline of space experiment GREENHOUSE-2 as a part of the fundamental biology investigations within the MIR/NASA space science program. Irradiation intensity (PAR) was 65 W/m2 and 38 W/m2 in the experiment and laboratory control, respectively. Values of other environmental parameters were MIR average (18-25 degrees C, relative air humidity in the interval between 40% and 75%, total gas pressure of about 660 to 860 mm Hg, partial oxygen pressure within the range from 140 to 200 mm Hg, partial carbon dioxide pressure up to 7 mm Hg). Experimental results showed that wheat cultivation in inhabited chamber under a modified lighting unit providing greater irradiation of the crop area produced more plant mass although seed production dropped. Low grain content in ears could be the aftermath of the gaseous trace contaminants in the chamber atmosphere.

NASA Discipline Life Support Systems↗

Mechanical properties of monolithic and particulate composites of L12 forms of Al3Ti

Preliminary studies of simple compressive properties of particulate composites with L1(2)-modified Al3Ti's as the matrices were performed as functions of matrix composition, amount of TiB2, processing technique, temperature, and strain rate. At and below about 900 K the introduction of TiB2 particles overwhelms minor chemical effects, and extremely high-yield strengths (about 2000 MPa at the 20 vol pct TiB2 level) were obtained. As L1(2)-modified Al3Ti has about half the density of the Ni-base superalloys, such values translate to strength/density ratios approximately four times those for superalloys. This advantage is not maintained by the Al3Ti-based composites above about 1000 K, particularly under slow strain rate plastic flow conditions, and it is proposed that this behavior could be due to the dissolution of intermetallic second phases as well as grain boundary creep mechanisms.

Whittenberger, J. D.↗

A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

Paciesas, W. S.↗