Fog and Cloud Induced Aerosol Modification Observed by AERONET

Large fine mode (sub-micron radius) dominated aerosols in size distributions retrieved from AERONET have been observed after fog or low-altitude cloud dissipation events. These column-integrated size distributions have been obtained at several sites in many regions of the world, typically after evaporation of low altitude cloud such as stratocumulus or fog. Retrievals with cloud processed aerosol are sometimes bimodal in the accumulation mode with the larger size mode often approx.0.4 - 0.5 microns radius (volume distribution); the smaller mode typically approx.0.12 to aprrox.0.20 microns may be interstitial aerosol that were not modified by incorporation in droplets and/or aerosol that are less hygroscopic in nature. Bimodal accumulation mode size distributions have often been observed from in situ measurements of aerosols that have interacted with clouds, and AERONET size distribution retrievals made after dissipation of cloud or fog are in good agreement with particle sizes measured by in situ techniques for cloud-processed aerosols. Aerosols of this type and large size range (in lower concentrations) may also be formed by cloud processing in partly cloudy conditions and may contribute to the shoulder of larger size particles in the accumulation mode retrievals, especially in regions where sulfate and other soluble aerosol are a significant component of the total aerosol composition. Observed trends of increasing aerosol optical depth (AOD) as fine mode radius increased suggests higher AOD in the near cloud environment and therefore greater aerosol direct radiative forcing than typically obtained from remote sensing, due to bias towards sampling at low cloud fraction.

Eck, T. F.↗

Radiative Closure Experiments at a Cloud-Free Desert Site, Nevada, as Part of MISR Algorithm Validation

Radiative closure experiments involving a comparison between surface-measured spectral irradiance and the surface irradiance calculated according to a radiative transfer code at a desert site in Nevada under clear skies, yield the result that agreement between the two requires presence of an absorbing aerosol component with an imaginary refractive index equal to 0.03 and a 50:50 mix by optical depth of small and large particles with log-normal size distributions.

MISR experiment field observations calibration dat↗

Global environmental monitoring with the EOS multi-angle imaging spectroradiometer (MISR)

The MISR provides a unique opportunity for studying the ecology and climate of the earth through the acquisition of systematic, global multiangle imagery in reflected sunlight. MISR uses nine cameras: a nadir camera and two banks of four cameras each pointed forward and aftward along the spacecraft ground track to image the earth at +/-30.7, +/-45.6, +/-60.0, and +/-72.5 deg. Radiometrically calibrated images at each angle will be obtained in four spectral bands centered at 440, 550, 670, and 860 nm. MISR will take image data in two different spatial resolution modes: local mode, in which selected targets are observed with 240-m spatial sampling, and global mode, where the entire sunlit eEarth is observed continuously with 1.92-km sampling. The instrument is capable of acquiring global coverage every nine days.

Diner, D. J.↗

Atmospheric correction of high resolution land surface images

Algorithms to correct for atmospheric-scattering effects in high-spatial resolution land-surface images require the ability to perform rapid and accurate computations of the top-of-atmosphere diffuse radiance field for arbitrarily general surface reflectance distributions (which may be both heterogeneous and non-Lambertian) and atmospheric models. Using three-dimensional radiative transfer (3DRT) theory algorithms are being developed. The methodology used to perform the 3DRT calculations is described. It is shown how these calculations are used to perform atmospheric corrections, and the sensitivity of the retrieved surface reflectances to atmospheric structural parameters is illustrated.

Diner, D. J.↗

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS): Inflight radiometric calibration and the determination of surface reflectance

The inflight radiometric performance of AVIRIS is presented together with a comparison of methods of recovering surface spectral reflectance from the data. Performance is evaluated by comparing radiance predicted from AVIRIS with radiance generated from the LOWIRAN 6 atmospheric model and measured surface reflectance. Comparisons show apparent agreement to within a few percent between 1800 and 2450 nm. Between 600 and 1800 nm the response of AVIRIS is systematically low by as much as 70 percent, and between 400 and 600 nm it is higher than expected. These problems are traced to thermal distortions of the instrument, and to detachment during flight of optical fibers connecting foreoptics to two of four spectrometers in the instrument. Of three methods studied, an empirical one involving calibration curves constructed from field reflectance measurements returns accurate predictions of the surface reflectance independent of the actual radiometric significance of the flight data.

Conel, J. E.↗