Search NASA⌕ Search

Engineering topics

Brunett, A. J.

Publications and source records attributed to Brunett, A. J..

SAS4A/SASSYS-1 Verification Testing for Sodium Fast Reactor Applications (Acceptance Testing Report)

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal- cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. To support demonstration of software pedigree and confirm key functional requirements, this report has been generated to provide detailed verification of the software. Although SAS was developed to support the analysis of any liquid-metal-cooled nuclear reactor, the acceptance testing described in this document focuses on the verification of SAS capabilities as they relate to pool-type Sodium Fast Reactors (SFRs). This report includes documentation of the test problem definition, analytical solution(s), computational solution(s), acceptance criteria, comparisons of analytical/computational solutions, and determination of acceptance of the computational solution(s). Deviations from acceptance criteria are noted.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Passive Safety System Reliability Analysis: Methodology, Application, and Results

Many advanced reactor designs rely on passive systems to provide assurance that certain safety functions, such as reactivity control and reactor heat removal, are maintained during transient scenarios. The performance of these systems is sensitive to boundary and environmental conditions and can lead to functional failure, which is the inability of the system to perform as intended even without any physical failures. Additionally, conditions can cause the passive systems to operate in an intermediate or degraded state. These operational modes of passive systems and their overall reliability can be difficult to capture in traditional probabilistic frameworks where discrete operating modes are assumed or time-dependent boundary conditions are not accounted for. Novel strategies and methods are needed to be able to capture the reliability of these passive systems and their impact on facility safety. The current abstract provides a summary of such a methodology and examples of its use in a case study, the GE Hitachi (GEH) PRISM probabilistic safety assessment (PSA), and the U.S. Department of Energy (USDOE) Versatile Test Reactor (VTR) PSA.

Bucknor, M.↗

Qualification of SAS4A/SASSYS-1 for Sodium-Cooled Fast Reactor Authorization and Licensing (Final CRADA Report)

This project focuses on assessment and qualification of the SAS4A/SASSYS-1 advanced reactor safety analysis code and its capacity to fulfill requirements associated with license/authorization of a sodium-cooled fast reactor (SFR). Specific objectives of this proposal include: development of a formal documentation requirements matrix that complies with a vendor’s NQA-1 program to identify needs for qualification documentation; completion of software methods qualification gap analysis to identify and close gaps in the verification and validation basis of the software; generation of an Acceptance Test Report to confirm compliance with the software requirements specification; and closure of gaps in Software Design Description (SDD) to assist with the eventual generation of a Modeling Licensing Topic Report (LTR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of SAS4A/SASSYS Code Developments (FY2018)

SAS4A/SASSYS is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. [1] With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for nearly fifty years. It has been identified as a critical element of safety analysis capabilities for the U.S. Department of Energy, [2] and it will be used to perform the transient safety analysis required to support the authorization basis for the Versatile Test Reactor (VTR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fast Reactor Methods Development Plan

Fast reactor design and safety analysis methods (computer codes) have been under development for approximately sixty years. During the first forty years, code development was driven by the immediate needs of operational facilities such as Experimental Breeder Reactors I and II and the Fast Flux Test Facility. Development was further driven by programmatic needs to support advanced reactor programs such as the Clinch River Breeder Reactor Project and the Advanced Liquid Metal Reactor Program. By the early 1990s, design and safety analysis codes had been well established to addressed the unique characteristics of fast reactors. During the subsequent twenty years, however, development was nearly stagnant as a result of U.S. Government policy changes that abruptly canceled nearly all of the fast reactor research in the United States. As a result, the state of fast reactor design and safety analysis methods has deteriorated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of the SAS4A/SASSYS-1 Safety Analysis Code

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced reactors. This report summarizes the current status of SAS4A/SASSYS-1, including the implementation of software quality assurance procedures for configuration management, new licenses, current users, and a gap assessment of the test suite. The existing copyright has been extended for an additional five years, which was essential so that Argonne can continue developing, distributing, and supporting the software for both domestic use and international collaborations. SAS4A/SASSYS-1 Version 5.2 was completed in March 2017 and released to users in May. The importance of SAS4A/SASSYS-1 maintenance reflects its relevance to a number of U.S. Department of Energy programs as well as domestic and international collaborations. External collaborations have also produced improvements in the SAS4A/SASSYS-1 code, and these are noted in this report. SAS4A/SASSYS-1 has a growing user base that continues to strengthen the promotion of advanced non-LWR reactor concepts. Additional users will help solidify DOE’s leadership role in fast reactor safety both domestically and in international collaborations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

U.S. Sodium Fast Reactor Codes and Methods: Current Capabilities and Path Forward

The United States has extensive experience with the design, construction, and operation of sodium cooled fast reactors (SFRs) over the last six decades. Despite the closure of various facilities, the U.S. continues to dedicate research and development (R&D) efforts to the design of innovative experimental, prototype, and commercial facilities. Accordingly, in support of the rich operating history and ongoing design efforts, the U.S. has been developing and maintaining a series of tools with capabilities that envelope all facets of SFR design and safety analyses. This paper provides an overview of the current U.S. SFR analysis toolset, including codes such as SAS4A/SASSYS-1, MC2-3, SE2-ANL, PERSENT, NUBOW-3D, and LIFE-METAL, as well as the higher-fidelity tools (e.g. PROTEUS) being integrated into the toolset. Current capabilities of the codes are described and key ongoing development efforts are highlighted for some codes.

safety codes↗

The SAS4A/SASSYS-1 Safety Analysis Code System, Version 5

The SAS4A/SASSYS-1 computer code is developed by Argonne National Laboratory for thermal, hydraulic, and neutronic analysis of power and flow transients in liquidmetal- cooled nuclear reactors (LMRs). SAS4A was developed to analyze severe core disruption accidents with coolant boiling and fuel melting and relocation, initiated by a very low probability coincidence of an accident precursor and failure of one or more safety systems. SASSYS-1, originally developed to address loss-of-decay-heat-removal accidents, has evolved into a tool for margin assessment in design basis accident (DBA) analysis and for consequence assessment in beyond-design-basis accident (BDBA) analysis. SAS4A contains detailed, mechanistic models of transient thermal, hydraulic, neutronic, and mechanical phenomena to describe the response of the reactor core, its coolant, fuel elements, and structural members to accident conditions. The core channel models in SAS4A provide the capability to analyze the initial phase of core disruptive accidents, through coolant heat-up and boiling, fuel element failure, and fuel melting and relocation. Originally developed to analyze oxide fuel clad with stainless steel, the models in SAS4A have been extended and specialized to metallic fuel with advanced alloy cladding. SASSYS-1 provides the capability to perform a detailed thermal/hydraulic simulation of the primary and secondary sodium coolant circuits and the balance-ofplant steam/water circuit. These sodium and steam circuit models include component models for heat exchangers, pumps, valves, turbines, and condensers, and thermal/hydraulic models of pipes and plena. SASSYS-1 also contains a plant protection and control system modeling capability, which provides digital representations of reactor, pump, and valve controllers and their response to input signal changes.

97 MATHEMATICS AND COMPUTING↗

SAS4A/SASSYS-1 Code Improvements for FY2016

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced reactors. This report summarizes ongoing tasks to modernize the SAS4A/SASSYS-1 code system to improve internal data management, update several other code modules, and add new features. Code modernization activities focused on eliminating legacy data management in the balance-of-plant module, which was the only module that still used non-portable data allocation. Code extensions include the development of a new axial expansion model that can accurately account for non-uniform or heterogeneous fuel compositions. The most significant accomplishment is the addition of uncertainty quantification capabilities for transient simulations using the Dakota toolkit from Sandia National Laboratory. The motivation for performing these updates stems from the relevance of SAS4A/SASSYS-1 to a number of U.S. Department of Energy programs as well as domestic and international collaborations. External collaborations have also produced improvements in the SAS4A/SASSYS-1 code, and these are summarized in this report. SAS4A/SASSYS-1 has a growing user base that continues to strengthen the promotion of advanced reactor concepts such as sodium cooled fast reactors. Additional users will help solidify DOE’s leadership role in fast reactor safety both domestically and in international collaborations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FASTER Test Reactor Preconceptual Design Report

The FASTER test reactor plant is a sodium-cooled fast spectrum test reactor that provides high levels of fast and thermal neutron flux for scientific research and development. The 120MWe FASTER reactor plant has a superheated steam power conversion system which provides electrical power to a local grid allowing for recovery of operating costs for the reactor plant.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of the TREAT LEU Conceptual Design

Analyses were performed to evaluate the performance of the low enriched uranium (LEU) conceptual design fuel for the conversion of the Transient Reactor Test Facility (TREAT) from its current highly enriched uranium (HEU) fuel. TREAT is an experimental nuclear reactor designed to produce high neutron flux transients for the testing of reactor fuels and other materials. TREAT is currently in non-operational standby, but is being restarted under the U.S. Department of Energy’s Resumption of Transient Testing Program. The conversion of TREAT is being pursued in keeping with the mission of the Department of Energy National Nuclear Security Administration’s Material Management and Minimization (M3) Reactor Conversion Program. The focus of this study was to demonstrate that the converted LEU core is capable of maintaining the performance of the existing HEU core, while continuing to operate safely. Neutronic and thermal hydraulic simulations have been performed to evaluate the performance of the LEU conceptual-design core under both steady-state and transient conditions, for both normal operation and reactivity insertion accident scenarios. In addition, ancillary safety analyses which were performed for previous LEU design concepts have been reviewed and updated as-needed, in order to evaluate if the converted LEU core will function safely with all existing facility systems. Simulations were also performed to evaluate the detailed behavior of the UO 2 -graphite fuel, to support future fuel manufacturing decisions regarding particle size specifications. The results of these analyses will be used in conjunction with work being performed at Idaho National Laboratory and Los Alamos National Laboratory, in order to develop the Conceptual Design Report project deliverable.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Results of Ancillary Safety Analyses Supporting TREAT LEU Conversion Activities

The Transient Reactor Test Facility (TREAT), located at Idaho National Laboratory (INL), is a test facility designed to evaluate the performance of reactor fuels and materials under transient accident conditions. The facility, an air-cooled, graphite-moderated reactor designed to utilize fuel containing high-enriched uranium (HEU), has been in non-operational standby status since 1994. Currently, in support of the missions of the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Material Management and Minimization (M3) Reactor Conversion Program, a new core design is being developed for TREAT that will utilize low-enriched uranium (LEU). The primary objective of this conversion effort is to design an LEU core that is capable of meeting the performance characteristics of the existing HEU core. Minimal, if any, changes are anticipated for the supporting systems (e.g. reactor trip system, filtration/cooling system, etc.); therefore, the LEU core must also be able to function with the existing supporting systems, and must also satisfy acceptable safety limits. In support of the LEU conversion effort, a range of ancillary safety analyses are required to evaluate the LEU core operation relative to that of the existing facility. These analyses cover neutronics, shielding, and thermal hydraulic topics that have been identified as having the potential to have reduced safety margins due to conversion to LEU fuel, or are required to support the required safety analyses documentation. The majority of these ancillary tasks have been identified in [1] and [2]. The purpose of this report is to document the ancillary safety analyses that have been performed at Argonne National Laboratory during the early stages of the LEU design effort, and to describe ongoing and anticipated analyses. For all analyses presented in this report, methodologies are utilized that are consistent with, or improved from, those used in analyses for the HEU Final Safety Analysis Report (FSAR) [3]. Depending on the availability of historical data derived from HEU TREAT operation, results calculated for the LEU core are compared to measurements obtained from HEU TREAT operation. While all analyses in this report are largely considered complete and have been reviewed for technical content, it is important to note that all topics will be revisited once the LEU design approaches its final stages of maturity. For most safety significant issues, it is expected that the analyses presented here will be bounding, but additional calculations will be performed as necessary to support safety analyses and safety documentation. It should also be noted that these analyses were completed as the LEU design evolved, and therefore utilized different LEU reference designs. Preliminary shielding, neutronic, and thermal hydraulic analyses have been completed and have generally demonstrated that the various LEU core designs will satisfy existing safety limits and standards also satisfied by the existing HEU core. These analyses include the assessment of the dose rate in the hodoscope room, near a loaded fuel transfer cask, above the fuel storage area, and near the HEPA filters. The potential change in the concentration of tramp uranium and change in neutron flux reaching instrumentation has also been assessed. Safety-significant thermal hydraulic items addressed in this report include thermally-induced mechanical distortion of the grid plate, and heating in the radial reflector.

Brunett, A. J.↗