Search NASASearch

Engineering topics

Bryan, C. J.

Publications and source records attributed to Bryan, C. J..

Comparative results of autogenous ignition temperature measurements by ASTM G 72 and pressurized scanning calorimetry in gaseous oxygen

The autogenous ignition temperature of four materials was determined by ASTM (G 72) and pressurized differential scanning calorimetry at 0.68-, 3.4-, and 6.8-MPa oxygen pressure. All four materials were found to ignite at lower temperatures in the ASTM method. The four materials evaluated in this program were Neoprene, Vespel SP-21, Fluorel E-2160, and nylon 6/6.

Bryan, C. J.

NASA mechanical impact testing in high-pressure oxygen

Three independently developed high-pressure gaseous oxygen mechanical impact testers have been used to evaluate materials for the Space Shuttle Program. A test program evaluating the performance of these test systems is described. The gaseous and liquid oxygen test procedures and equipment are considered along with the material selection procedures. The results of the NASA mechanical impact tester variability study are presented, including penetration function curves and curve parameters and equivalent energies and comparisons of high-pressure testers at ambient pressure and temperature, ambient temperature and 34 MPa, and cryogenic temperature and 34 MPa. Finally, a summary of NASA mechanical impact test data is presented.

Bryan, C. J.

System for sterilizing objects

A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

Bryan, C. J.

LOX/GOX mechanical impact tester assessment

The performances of three existing high pressure oxygen mechanical impact test systems were tested at two different test sites. The systems from one test site were fabricated from the same design drawing, whereas the system tested at the other site was of different design. Energy delivered to the test sample for each test system was evaluated and compared. Results were compared to the reaction rates obtained.

Bransford, J. W.

Continuous sterilization of plumbing systems

Continuous sterilization of plumbing, such as in hospitals, clinics, and biological testing laboratories is possible with ethylene oxide/Freon 12 (ETO/F-12) humidifier developed for sterilization of potable water systems.

Bryan, C. J.

Analysis of surface tris (2,3-dibromopropyl) phosphate on chlorobutyl rubber SCAPE suits

Tris (2,30-dibromopropyl) phosphate was used to confer flame retardant properties on butyl rubber formulations used in protective clothing such as the self-contained atmospheric protective ensembles (SCAPE suits) worn at Kennedy Space Center in support of Apollo, Skylab, and Apollo-Soyuz missions since 1966. Because tris (2,3-dibromopropyl) phosphate is mutagenic, surface concentrations of the compound in SCAPE suits were investigated as were as potential methods of removing or isolating it. Analytical procedures for determining surface concentrations of the tris compound on non-porous materials are described. Soap-and-water washing is the most efficient method of removing the compound from fabricated SCAPE suits and unused material.

Schehl, T. A.

High pressure liquid and gaseous oxygen impact sensitivity evaluation of materials for use at Kennedy Space Center

The sensitivity of materials in contact with gaseous oxygen (GOX) or liquid oxygen (LOX) was examined. Specifically, the reactivity of materials when in contact with GOX or LOX if subjected to such stimuli as mechanical impact, adiabatic compression (pneumatic impact), or an electrical discharge in the form of a spark were examined. Generally, materials are more sensitive in gaseous oxygen than in liquid oxygen and impact sensitivity is known to increase with increasing pressure. Materials presently being used or considered for use in oxygen systems at KSC were evaluated. Results are given in tabular form.

Bryan, C. J.

Test of LOX compatibility for asphalt and concrete runway materials

A literature survey and a telephone canvass of producers and users of LOX is reported which yielded one report of an accident resulting from a LOX spill on asphalt, one discussion of hazardous conditions, and an unreferenced mention of an incident. Laboratory tests using standard LOX impact apparatus yielded reactions with both old and new alphalt, but none with concrete. In the final test, using a larger sample of asphalt, the reaction caused extensive damage to equipment. Initial field experiments using 2-meter square asphalt slabs covered with LOX, conducted during rainy weather, achieved no reaction with plummets, and limited reaction with a blasting cap as a reaction initiator. In a final plummet-initiated test on a dry slab, a violent reaction, which appeared to have propagated over the entire slab surface, destroyed the plummet fixture and threw fragments as far as 48 meters.

Moyers, C. V.

KSC lubricant testing program

A program was conducted to evaluate the performance of various lubricants in use and considered for use at Kennedy Space Center (KSC). The overall objectives of the program were to: (1) determine the lubrication characteristics and relative corrosion resistance of lubricants in use and proposed for use at KSC; (2) identify materials which may be equivalent to or better than KELF-90 and Krytox 240 AC greases; and (3) identify or develop an improved lubricating oil suitable for use in liquid oxygen (LOX) pumps at KSC. It was concluded that: (1) earth gel thickened greases are very poor corrosion preventive materials in the KSC environment; (2) Halocarbon 25-5S and Braycote 656 were suitable substiutes for KELF-90 and Krytox 240 AC respectively; and (3) none of the oils evaluated possessed the necessary inertness, lubricity, and corrosion prevention characteristics for the KSC LOX pumping systems in their present configuration.

Lockhart, B. J.

Autoignition test cell Patent

Test chamber for determining decomposition and autoignition of materials used in spacecraft under controlled environmental conditions

Bryan, C. J.