Design and Fabrication of a Dielectric Total Internal Reflecting Solar Concentrator and Associated Flux Extractor for Extreme High Temperature (2500K) Applications

The Analex Corporation, under contract to the NASA Lewis Research Center (LeRC), Cleveland, Ohio, recently evaluated the feasibility of utilizing refractive secondary concentrators for solar heat receivers operating at temperatures up to 2500K. The feasibility study pointed out a number of significant advantages provided by solid single crystal refractive devices over the more conventional hollow reflective compound parabolic concentrators (CPCs). In addition to the advantages of higher concentration ratio and efficiency, the refractive concentrator, when combined with a flux extractor rod, provides for flux tailoring within the heat receiver cavity. This is a highly desirable, almost mandatory, feature for solar thermal propulsion engine designs presently being considered for NASA and Air Force thermal applications. Following the feasibility evaluation, the NASA-LeRC, NASA-Marshall Space Flight Center (MSFC), and Analex Corporation teamed up to design, fabricate, and test a refractive secondary concentrator/flux extractor system for potential use in the NASA-MSFC "Shooting Star" flight experiment. This paper describes the advantages and technical challenges associated with the design methodologies developed and utilized and the material and fabrication limitations encountered.

Soules, Jack A.↗

Compact Color Schlieren Optical System

Compact, rugged optical system developed for use in rainbow schlieren deflectometry. Features unobscured telescope with focal-length/aperture-width ratio of 30. Made of carefully selected but relatively inexpensive parts. All of lenses stock items. By-product of design is optical system with loose tolerances on interlens spacing. One of resulting advantages, insensitivity to errors in fabrication of optomechanical mounts. Another advantage is ability to compensate for some of unit-to-unit variations inherent in stock lenses.

Buchele, Donald R.↗

Quantitative rainbow schlieren deflectometry

In the rainbow schlieren apparatus, a continuously graded rainbow filter is placed in the back focal plane of the decollimating lens. Refractive-index gradients in the test section thus appear as gradations in hue rather than irradiance. A simple system is described wherein a conventional color CCD array and video digitizer are used to quantify accurately the color attributes of the resulting image, and hence the associated ray deflections. The present system provides a sensitivity comparable with that of conventional interferometry, while being simpler to implement and less sensitive to mechanical misalignment.

Greenberg, Paul S.↗

Compact color schlieren optical system

A compact optical system for use with rainbow schlieren deflectometry is described. Both halves of the optical system consist of well-corrected telescopes whose refractive elements are all from manufacturer's stock catalogs, with the reflective primary being a spherical surface. As a result, the system is relatively easy to construct and meets the requirement of long focal length for quantitative rainbow schlieren measurements.

Buchele, Donald R.↗

Laser diffraction particle sizing: Instrument probe volume relocation and elongation

The effective probe volume of laser diffraction particle sizing instruments depends on many instrument parameters. In particular the probe volume axial boundaries and its location along laser beam are essentially defined by the onset of a vignetting effect where light scattered at large angles from small particles misses the transform lens. This vignetting effect results in a probe volume that must be inconveniently close to the lens in order to detect smaller diameter particles (less than 100 micrometers). With the addition of an appropriately designed Keplerian telescope, the probe volume may be relocated and elongated. The theory of operation of this supplemental optical system is described. Design considerations for these supplemental optical systems are described, including recommendations for lens specifications, assembly and use. An image transfer system is described which has been designed for use on a Malvern 2600HSD instrument. Experimental validation of this image transfer system is described.

Anderson, Robert C.↗

Scattered-light scanner measurements of cryogenic liquid-jet breakup

The effect of highly turbulent Mach 1 gas flow and high thermal gradients on drop size measurements was investigated with a scattered light scanner. The instrument, developed at NASA-Lewis, was used to measure characteristic drop diameters or cyrogenic liquid sprays. By correcting for gas turbulence and thermal gradient affects, it was possible to obtain good reproducible data with the scattered light scanner. Tests were conducted primarily in the aerodynamic-stripping regime of liquid atomization and it was found that the loss of small droplets due to vaporization and dispersion had a marketed effect on drop size measurements. The nitrogen gas flow rate exponent of 1.33 is the same as that predicted by atomization theory for liquid jet breakup in high velocity gas flow. However, when the sprays were sampled farther downstream of the atomizer, at axial distances of 2.5 and 4.5 cm, the exponent for W sub n decreased 1.2 and 0.9, respectively. This was attributed to the loss of small droplets due to vaporization when values of downstream axial distances exceeded 1.3 cm.

Ingebo, Robert D.↗

Particle sizing by weighted measurements of scattered light

A description is given of a measurement method, applicable to a poly-dispersion of particles, in which the intensity of scattered light at any angle is weighted by a factor proportional to that angle. Determination is then made of four angles at which the weighted intensity is four fractions of the maximum intensity. These yield four characteristic diameters, i.e., the diameters of the volume/area mean (D sub 32 the Sauter mean) and the volume/diameter mean (D sub 31); the diameters at cumulative volume fractions of 0.5 (D sub v0.5 the volume median) and 0.75 (D sub v0.75). They also yield the volume dispersion of diameters. Mie scattering computations show that an average diameter less than three micrometers cannot be accurately measured. The results are relatively insensitive to extraneous background light and to the nature of the diameter distribution. Also described is an experimental method of verifying the conclusions by using two microscopic slides coated with polystyrene microspheres to simulate the particles and the background.

Buchele, Donald R.↗

Small-droplet spray measurements with a scattered-light scanner

Interacting two-phase flow through pneumatic two-fluid nozzles was investigated to determine the effect of nitrogen gas mass-velocity on the Sauter mean diameter of water sprays produced by the breakup of small diameter liquid-jets in high velocity gas streams. Tests were conducted primarily in the aerodynamic-stripping regime of liquid-jet atomization. It was found that the loss of droplets due to vaporization and dispersion had a marked effect on drop size measurements. A scattered-light scanner, developed at NASA Lewis Research Center was used to measure Sauter mean diameters, D sub 32, as small as 5 microns, which were correlated with nitrogen gas mass-velocity to give the following expression: D(sup -1)(sub 32) = 11.7(rho (sub n) V(sub n))(sup 1.33) where D sub 32 and p(sub n)V(sub n) are given in centimeters and g/sq cm-sec, respectively. The exponent 1.33 is the same as that predicted by atomizing theory for liquid-jet breakup in high velocity gas streams.

Ingebo, Robert D.↗