Testing of Candidate Batteries for Global Positioning System

Three lithium batteries proposed as candidates for use in the Global Positioning System are studied. The batteries are discharged at several rates and temperatures both before and after environmental testing. Batteries are heated inside a closed chamber until they vent. Samples of the vented gases are analyzed for components which might be toxic. The test results raise concerns about each of the proposed batteries.

Barnes, J. A.↗

High Rate Discharge Studies of LI/SO2 Batteries

A battery composed of twelve lithium/sulfur dioxide D size cells in series is forced discharged at 21 amperes. This current is established by the proposed use of the battery and represented a discharge condition which might produce venting. Discharge of the battery into voltage reversal results not only in cells venting but also in the violent rupture of at least one cell.