Search NASA⌕ Search

Engineering topics

Bulk, Alexander (ORCID:0000000267646848)

Publications and source records attributed to Bulk, Alexander (ORCID:0000000267646848).

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Performance Assessment of High-Efficiency Refrigerated Display Cases with Low-GWP Refrigerants: Preprint

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas (GHG) reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison was to assess the energy performance of two high efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513a, respectively. Performance of these display cases were compared to a baseline fixture using HFC (R-134a) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores, and small supermarkets. The high efficiency cases were equipped with energy efficient lighting, improved panel insulation, high efficiency evaporator and condenser fan motors, and high effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions. However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining target product temperature, the energy efficient fixtures containing R-290 and R-513a consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134a refrigerant. The daily energy consumption of the R-290, R-513a, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗