Three Proposed Compendia for Genesis Solar Wind Samples: Science Results, Collector Materials Characterization and Cleaning Techniques

Final Paper and not the abstract is attached. Introduction: Planetary material and cosmochemistry research using Genesis solar wind samples (including the development and implementation of cleaning and analytical techniques) has matured sufficiently that compilations on several topics, if made publically accessible, would be beneficial for researchers and reviewers. We propose here three compendia based on content, organization and source of documents (e.g. published peer-reviewed, published, internal memos, archives). For planning purposes, suggestions are solicited from potential users of Genesis solar wind samples for the type of science content and/or organizational style that would be most useful to them. These compendia are proposed as living documents, periodically updated. Similar to the existing compendia described below, the curation compendia are like library or archival finding aids, they are guides to published or archival documents and should not be cited as primary sources.

Allton, J. H.

Small Particulate Contamination Survey Of Genesis Flight Sample 61423

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind stop in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We continue to work with the community of scientists analyzing Genesis samples using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. We continue to evaluate the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping spacecraft and terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.

Genesis Solar Wind Sample 61422: Experiment in Variation of Sequence of Cleaning Solvent for Removing Carbon-Bearing Contamination

The recovered Genesis collector fragments are heavily contaminated with crash-derived particulate debris. However, megasonic treatment with ultra-pure-water (UPW; resistivity (is) greater than18 meg-ohm-cm) removes essentially all particulate contamination greater than 5 microns in size [e.g.1] and is thus of considerable importance. Optical imaging of Si sample 60336 revealed the presence of a large C-rich particle after UPW treatment that was not present prior to UPW. Such handling contamination is occasionally observed, but such contaminants are normally easily removed by UPW cleaning. The 60336 particle was exceptional in that, surprisingly, it was not removed by additional UPW or by hot xylene or by aqua regia treatment. It was eventually removed by treatment with NH3-H2O2. Our best interpretation of the origin of the 60336 particle was that it was adhesive from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. It is possible that the insoluble nature of the 60336 particle comes from interaction of the Post-It adhesive with UPW. An occasional bit of Post-It adhesive is not a major concern, but C particulate contamination also occurs from the heat shield of the Sample Return Capsule (SRC) and this is mixed with inorganic contamination from the SRC and the Utah landing site. If UPW exposure also produced an insoluble residue from SRC C, this would be a major problem in chemical treatments to produce clean surfaces for analysis. This paper reports experiments to test whether particulate contamination was removed more easily if UPW treatment was not used.

Allton, J. H.

Genesis Solar Wind Collector Cleaning Assessment: Update on 60336 Sample Case Study

To maximize the scientific return of Genesis Solar Wind return mission it is necessary to characterize and remove a crash-derived particle and thin film surface contamination. A small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques. Here we present an update on the sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C). This sample has undergone multiple cleaning steps (see the table below): UPW spin wash, aggressive chemical cleanings (including aqua regia, hot xylene and RCA1), as well as optical and chemical (EDS, ToF-SIMS) imaging. Contamination appeared on the surface of 60336 after the initial 2007 UPW cleaning. Aqua regia and hot xylene treatment (8/13/2013) did little to remove contaminants. The sample was UPW cleaned for the third time and imaged (9/16/13). The UPW removed the dark stains that were visible on the sample. However, some features, like "the Flounder" (a large, 100 micron feature in Fig. 1b) appeared largely intact, resisting all previous cleaning efforts. These features were likely from mobilized adhesive, derived from the Post-It notes used to stabilize samples for transport from Utah after the hard landing. To remove this contamination, an RCA step 1 organic cleaning (RCA1) was employed. Although we are still uncertain on the nature of the Flounder and why it is resistant to UPW and aqua regia/hot xylene treatment, we have found RCA1 to be suitable for its removal. It is likely that the glue from sticky pads used during collector recovery may have been a source for resistant organic contamination [9]; however [8] shows that UPW reaction with crash-derived organic contamination does not make particle removal more difficult.

Goreva, Y. S.

Development of Genesis Solar Wind Sample Cleanliness Assessment: Initial Report on Sample 60341 Optical Imagery and Elemental Mapping

Since 2005 the Genesis science team has experimented with techniques for removing the contaminant particles and films from the collection surface of the Genesis fragments. A subset of ~40 samples have been designated as "cleaning matrix" samples. These are small samples to which various cleaning approaches are applied and then cleanliness is assessed optically, by TRXRF, SEM, ToF-SIMS, XPS, ellipsometry or other means [1-9]. Most of these sam-ples remain available for allocation, with cleanliness assessment data. This assessment allows evaluation of various cleaning techniques and handling or analytical effects. Cleaning techniques investigated by the Genesis community include acid/base etching, acetate replica peels, ion beam, and CO2 snow jet cleaning [10-16]. JSC provides surface cleaning using UV ozone exposure and ultra-pure water (UPW) [17-20]. The UPW rinse is commonly used to clean samples for handling debris between processing by different researchers. Optical microscopic images of the sample taken before and after UPW cleaning show what has been added or removed during the cleaning process.

Gonzalez, C. P.

Genesis Solar Wind Collector Cleaning Assessment: 60366 Sample Case Study

In order to recognize, localize, characterize and remove particle and thin film surface contamination, a small subset of Genesis mission collector fragments are being subjected to extensive study via various techniques [1-5]. Here we present preliminary results for sample 60336, a Czochralski silicon (Si-CZ) based wafer from the bulk array (B/C).

Goreva, Y. S.

ToF-SIMS Investigation of the Effectiveness of Acid-Cleaning procedures for Genesis Solar Wind Collectors

ToF-SIMS images of Genesis sample surfaces contain an incredible amount of important information, but they also show that the crash-derived surface contamination has many components, presenting a challenge to cleaning. Within the variability, we have shown that there are some samples which appear to be clean to begin with, e.g. 60471, and some are more contaminated. Samples 60493 and 60500 are a part of a focused study of the effectiveness of aqua regia and/or sulfuric acid cleaning of small flight Si implanted with Li-6 using ToF-SIMS.

Goreva, Y. S.

Cellulose Acetate Replica Cleaning Study of Genesis Non-Flight Sample 3CZ00327

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We are working interactively with the community of scientists analyzing Genesis samples, using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. That is, we are evaluating the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.

Cleaning Study of Genesis Sample 60487

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. Particles of Genesis wafers, brine from the Utah Testing Range and an organic film have deleterious effects on many of the high-resolution instruments that have been developed to analyze the implanted solar wind. We have conducted a correlative microscopic study of the efficacy of cleaning Genesis samples with megasonically activated ultrapure water and UV/ozone cleaning. Sample 60487, the study sample, is a piece of float-zone silicon from the B/C array approximately 4.995mm x 4.145 mm in size

Kuhlman, Kim R.

Application of CO2 Snow Jet Cleaning in Conjunction with Laboratory Based Total Reflection X-Ray Fluorescence

The Genesis mission was the first mission returning solar material to Earth since the Apollo program [1,2]. Unfortunately the return of the space craft on September 8, 2004 resulted in a crash landing, which shattered the samples into small fragments and exposed them to desert soil and other debris. Thus only small fragments of the original collectors are available, each having different degrees of surface contamination. Thorough surface cleaning is required to allow for subsequent analysis of solar wind material embedded within. An initial cleaning procedure was developed in coordination with Johnson Space Center which focused on removing larger sized particulates and a thin film organic contamination acquired during collection in space [3]. However, many of the samples have additional residues and more rigorous and/or innovative cleaning steps might be necessary. These cleaning steps must affect only the surface to avoid leaching and re-distribution of solar wind material from the bulk of the collectors. To aid in development and identification of the most appropriate cleaning procedures each sample has to be thoroughly inspected before and after each cleaning step. Laboratory based total reflection X-ray fluorescence (TXRF) spectrometry lends itself to this task as it is a non-destructive and surface sensitive analytical method permitting analysis of elements from aluminum onward present at and near the surface of a flat substrate [4]. The suitability of TXRF has been demonstrated for several Genesis solar wind samples before and after various cleaning methods including acid treatment, gas cluster ion beam, and CO2 snow jet [5 - 7]. The latter one is non-invasive and did show some promise on one sample [5]. To investigate the feasibility of CO2 snow jet cleaning further, several flown Genesis samples were selected to be characterized before and after CO2 snow application with sample 61052 being discussed below.

Schmeling, M.

Decontamination of Genesis Array Materials by UV Ozone Cleaning

Shortly after the NASA Genesis Mission sample return capsule returned to earth on September 8, 2004, the science team discovered that all nine ultra-pure semiconductor materials were contaminated with a thin molecular organic film approximately 0 to 100 angstroms thick. The organic contaminate layer, possibly a silicone, situated on the surface of the materials is speculated to have formed by condensation of organic matter from spacecraft off-gassing at the Lagrange 1 halo orbit during times of solar exposure. While the valuable solar wind atoms are safely secured directly below this organic contamination and/or native oxide layer in approximately the first 1000 angstroms of the ultra-pure material substrate, some analytical techniques that precisely measure solar wind elemental abundances require the removal of this organic contaminate. In 2005, Genesis science team laboratories began to develop various methods for removing the organic thin film without removing the precious material substrate that contained the solar wind atoms. Stephen Sestak and colleagues at Open University first experimented with ultraviolet radiation ozone (UV/O3) cleaning of several non-flight and flown Genesis silicon wafer fragments under a pure flowing oxygen environment. The UV/O3 technique was able to successfully remove organic contamination without etching into the bulk material substrate. At NASA Johnson Space Center Genesis Curation Laboratory, we have installed an UV/O3 cleaning devise in an ambient air environment to further experimentally test the removal of the organic contamination on Genesis wafer materials. Preliminary results from XPS analysis show that the UV/O3 cleaning instrument is a good non-destructive method for removing carbon contamination from flown Genesis array samples. However, spectroscopic ellipsometry results show little change in the thickness of the surface film. All experiments to date have shown UV/O3 cleaning method to be the best non-destructive method for removing organic contamination from the surface of the Genesis materials. The UV/O3 cleaning process can also clean carbon contamination to levels below non-flight standards. This can be seen by comparing sample 60260's carbon 10667 cps with non-flight Si carbon 21675 cps. Therefore, surface carbon contamination should not hinder the analysis of solar wind.

Calaway, Michael J.

Molecular Contamination on Anodized Aluminum Components of the Genesis Science Canister

Inspection of the interior of the Genesis science canister after recovery in Utah, and subsequently at JSC, revealed a darkening on the aluminum canister shield and other canister components. There has been no such observation of film contamination on the collector surfaces, and preliminary spectroscopic ellipsometry measurements support the theory that the films observed on the anodized aluminum components do not appear on the collectors to any significant extent. The Genesis Science Team has made an effort to characterize the thickness and composition of the brown stain and to determine if it is associated with molecular outgassing.Detailed examination of the surfaces within the Genesis science canister reveals that the brown contamination is observed to varying degrees, but only on surfaces exposed in space to the Sun and solar wind hydrogen. In addition, the materials affected are primarily composed of anodized aluminum. A sharp line separating the sun and shaded portion of the thermal closeout panel is shown. This piece was removed from a location near the gold foil collector within the canister. Future plans include a reassembly of the canister components to look for large-scale patterns of contamination within the canister to aid in revealing the root cause.

Burnett, D. S.

Genesis: Removing Contamination from Sample Collectors

The Genesis mission returned to Earth on September 8, 2004, experiencing a non-nominal reentry. The parachutes which were supposed to slow and stabilize the capsule throughout the return failed to deploy, causing the capsule to impact the desert floor at a speed of nearly 200 MPH. Both the science canister and the major components of the SRC were returned before nightfall on September 8 to the prestaged cleanroom at UTTR , avoiding prolonged exposure or pending weather changes which might further contaminate the samples. The majority of the contaminants introduced as a result of the anomalous landing were in the form of particulates, including UTTR dust and soil, carbon-carbon heat shield material, and shattered collector dust (primarily silicon and germanium). Additional information is included in the original extended abstract.

Lauer, H. V.

Status of Genesis Mo-Pt Foils

A total of 8,000 sq cm of Mo-coated Pt foils were exposed to solar wind for 884 days by the Genesis mission. Solar wind ions were captured in the surface of the Mo. Our objective is the measurement of long-lived radionuclides, such as Be-10, Al-26, Cl-36, and Mn-53, and short-lived radionuclides, such as Na-22 and Mn-54, in the captured sample of solar wind. The expected flux of these nuclides in the solar wind is 100 atom/sq cm yr or less. The hard landing of the SRC (Sample Return Capsule) at UTTR (Utah Test and Training Range) has resulted in contaminated and crumpled foils. Here we present a status report and revised plan for processing the foils.

Nishiizumi, K.

Genesis: Sorting Out the Pieces

The Genesis mission returned to Earth on September 8, 2004, experiencing a non-nominal reentry. The parachutes which were supposed to slow and stabilize the capsule throughout the return failed to deploy, causing the capsule to impact the desert floor at a speed of nearly 200 MPH. The result is that instead of receiving 301 intact solar wind collectors, mission personnel recovered and documented more than 10,000 collector fragments. Most of the fragments were pieces of the collector arrays but were not recovered on their original array locations. These were classified by size (longest dimension), identity (sometimes a guess) and found location (when known). The work took more than one month in Utah, and details are discussed elsewhere[1] The samples were transferred to their permanent home at the Johnson Space Center on October 4, 2004.

McNamara, K. M.

The Genesis Mission Solar Wind Collection: Solar-Wind Statistics over the Period of Collection

The NASA Genesis spacecraft was launched August 8, 2001 on a mission to collect samples of solar wind for 2 years and return them to earth September 8, 2004. Detailed analyses of the solar wind ions implanted into high-purity collection substrates will be carried out using various mass spectrometry techniques. These analyses are expected to determine key isotopic ratios and elemental abundances in the solar wind, and by extension, in the solar photosphere. Further, the photospheric composition is thought to be representative of the solar nebula with a few exceptions, so that the Genesis mission will provide a baseline for the average solar nebula composition with which to compare present-day compositions of planets, meteorites, and asteroids. The collection of solar wind samples is almost complete. Collection began for most substrates in early December, 2001, and is scheduled to be complete on April 2 of this year. It is critical to understand the solar-wind conditions during the collection phase of the mission. For this reason, plasma ion and electron spectrometers are continuously monitoring the solar wind proton density, velocity, temperature, the alpha/proton ratio, and angular distribution of suprathermal electrons. Here we report on the solar-wind conditions as observed by these in-situ instruments during the first half of the collection phase of the mission, from December, 2001 to present.

Barraclough, B. L.

The Genesis Solar Wind Collection Mission: Current Status

The NASA Genesis spacecraft was launched August 8, 2001 on a mission to collect samples of solar wind for greater than or equal to 2 years and then return them to Earth in 2004. Detailed analyses of the solar wind ions implanted into high-purity collection substrates will subsequently be carried out in earth-based laboratories using various mass spectrometry techniques. These analyses are expected to determine key isotopic ratios and elemental abundances in the solar wind and, by extension, in the solar photosphere. Further, the photospheric composition is thought to be representative of the solar nebula with a few exceptions so that the Genesis mission will provide a baseline for the average solar nebula composition with which to compare present-day compositions of planets, meteorites, and asteroids. The implications of the solar oxygen isotopic composition have been discussed. A list of other isotopic and elemental measurement objectives, and some of the rationale behind them, is given.

Barraclough, B. L.

Genesis Solar-Wind Sample Return Mission: The Materials

The Genesis spacecraft has two primary instruments which passively collect solar wind. The first is the collector arrays , a set of panels, each of which can deploy separately to sample the different kinds of solar wind (regimes). The second is the concentrator, an electrostatic mirror which will concentrate ions of mass 4 through mass 25 by about a factor of 20 by focusing them onto a 6 cm diameter target. When not deployed, these instruments fit into a compact canister. After a two year exposure time, the deployed instruments can be folded up, sealed into the canister, and returned to earth for laboratory analysis. Both the collector arrays and the concentrator will contain suites of ultra-high purity target materials, each of which is tailored to enable the analysis of a different family of elements. This abstract is meant to give a brief overview of the Genesis mission, insight into what materials were chosen for flight and why, as well as head s up information as to what will be available to planetary scientist for analysis when the solar-wind samples return to Earth in 2003. Earth. The elemental and isotopic abundances of the solar wind will be analyzed in state-of-the-art laboratories, and a portion of the sample will be archived for the use of future generations of planetary scientists. Technical information about the mission can be found at www.gps.caltech.edu/genesis.

Jurewicz, A. J. G.