Search NASA⌕ Search

Engineering topics

Burton, R. L.

Publications and source records attributed to Burton, R. L..

High pressure Mach 10 to 20 electrothermal hypersonic wind tunnel

A new technique is described for generating high enthalpy, long pulse flows for testing scramjet combustors at equivalent flight Mach numbers of 10 to 20. The approach derives from high pressure discharge technology developed for electrothermal guns and space thrusters. Cryogenic liquid air is heated with a high power electric discharge (500 MW for a 15 kg/sec test flow rate) in a capillary tube, generating a quasi-steady pressure of up to 6800 atm at 20,000 K. The heated air is mixed with additional cryogenic air and is expanded in a conventional supersonic nozzle to 0.5 to 1 atm at 3000 to 6000 m/sec. Combustion and nozzle expansion test time of approximately 300 m/sec are contemplated. Facility nozzle chemical kinetics calculations show that above Mach 16 increasing concentrations of argon and oxygen replenishment are required to obtain suitable test conditions. Initial experiments on a subscale test rig are described for 0.5 kg/sec and 300 atm pressure.

Burton, R. L.↗

Experiments on a repetitively pulsed electrothermal thruster

This paper presents experimental results from an investigation of a pulsed electrothermal (PET) thruster using water propellant. The PET thruster is operated on a calibrated thrust stand, and produces a thrust to power ratio of T/P = 0.07 + or - 0.01 N/kW. The discharge conditions are inferred from a numerical model which predicts pressure and temperature levels of 300-500 atm and 20,000 K, respectively. These values in turn correctly predict the measured values of impulse bit and discharge resistance. The inferred ideal exhaust velocity from these conditions is 17 km/sec, but the injection of water propellant produces a test tank background pressure of 10-20 Torr, which reduces the exhaust velocity to 14 km/sec. This value corresponds to a thrust efficiency of 54 + or - 7 percent when all experimental errors are taken into account.

Burton, R. L.↗

Investigation of a repetitive pulsed electrothermal thruster

A pulsed electrothermal (PET) thruster with 1000:1 ratio nozzle is tested in a repetitive mode on water propellant. The thruster is driven by a 60J pulse forming network at repetition rates up to 10 Hz (600W). The pulse forming network has a .31 ohm impedance, well matched to the capillary discharge resistance of .40 ohm, and is directly coupled to the thruster electrodes without a switch. The discharge is initiated by high voltage breakdown, typically at 2500V, through the water vapor in the interelectrode gap. Water is injected as a jet through a .37 mm orifice on the thruster axis. Thruster voltage, current and impulse bit are recorded for several seconds at various power supply currents. Thruster to power ratio is typically T/P = .07 N/kW. Tank background pressure precludes direct measurement of exhaust velocity which is inferred from calculated pressure and temperature in the discharge to be about 14 km/sec. Efficiency, based on this velocity and measured T/P is .54 + or - .07. Thruster ablation is zero at the throat and becomes measurable further upstream, indicating that radiative ablation is occurring late in the pulse.

Burton, R. L.↗

Investigation of a pulsed electrothermal thruster system

The performance of an ablative wall Pulsed Electrothermal (PET) thruster is accurately characterized on a calibrated thrust stand, using polyethylene propellant. The thruster is tested for four configurations of capillary length and pulse length. The exhaust velocity is determined with twin time-of-flight photodiode stagnation probes, and the ablated mass is measured from the loss over ten shots. Based on the measured thrust impulse and the ablated mass, the specific impulse varies from 1000 to 1750 seconds. The thrust to power varies from .05 N/kW (quasi-steady mode) to .10 N/kW (unsteady mode). The thruster efficiency varies from .56 at 1000 seconds to .42 at 1750 seconds. A conceptual design is presented for a 40 kW PET propulsion system. The point design system performance is .62 system efficiency at 1000 seconds specific impulse. The system's reliability is enhanced by incorporating 20, 20 kW thruster modules which are fired in pairs. The thruster design is non-ablative, and uses water propellant, from a central storage tank, injected through the cathode.

Burton, R. L.↗

Experimental investigation of the pulsed electrothermal (PET) thruster

Burton et al. (1982) have discussed the theory of the Pulsed Electrothermal (PET) thruster, a device which in principle can operate with 70 percent efficiency at a specific impulse of 1000 seconds and higher. It is pointed out that this level of performance would be particularly attractive for orbit raising of large satellites and other near-earth missions, which cannot be easily accomplished by chemical propulsion. The present investigation is concerned with two PET thruster operating modes. A PET thruster was built and tested on a thrust stand. Exhaust velocities for polyethylene propellant vary from 20 to 27 km/sec. Single pulse specific impulse and efficiency measurements based on ablated mass show a thruster efficiency of 37-56 percent in the time range from 1000 to 1750 seconds. It is believed that an improved design with a thruster efficiency in the range from 70 to 80 percent might be possible.

Burton, R. L.↗

Proposed system design for a 20 kW pulsed electrothermal thruster

A conceptual design is presented for a Pulsed Electrothermal (PET) propulsion system for the Air Force Space Based Radar satellite, which has a mass of 7000 kg. The proposed system boosts the SBR satellite from 150 n.m. to 600 n.m. with a 4 deg plane change, for a total mission Delta v of 1 km/sec. Satellite power available is 50 kW, and 45 kW are used to drive two water-injected 20 kW PET thrusters, delivering 5.6 N thrust to the SBR at 1000 seconds specific impulse. The predicted mission trip time is 15 days. The proposed system consumes 850 kg of water propellant, stored in a central tank and injected with pressurized helium. Component mass estimates based on space-qualified hardware are presented for the propellant handling, power conditioning and thruster subsystems. The estimated total mass is 400 kg and the propulsion system specific mass is alpha = 10 kg/kW. The proposed system efficiency of 0.62 at 1000 seconds specific impulse is supported by experimental performance measurements.

Burton, R. L.↗

Investigation of a pulsed electrothermal thruster

Exhaust velocity and thrust measurements are performed on a pulsed electrothermal thruster using polyethylene and Teflon propellants. The results verify theoretical predictions of equilibrium flow in the nozzle, resulting in substantial recovery of the energy of dissociation and ionization. The thruster is tested in an unsteady mode (15 micro sec current pulse and 15 cm discharge length) and in a quasi-steady mode (48 micro sec current pulse and 5 cm discharge length). All tests are run at 2 kJ. The exhaust velocity of the propellant mass exiting during the current pulse is measured with two types of time of flight probes, and the impulse bit is measured on a thrust stand. It is inferred from both theory and experiment that an additional amount of mass is exhausted after the pulse. The measured thrust to power ratio for polyethylene is T/P = 0.10 NkW at 21 km/sec in the unsteady mode, and T/P = .053 N/kW at 27 km/sec in the quasi-steady mode, where the velocities are measured by the time-of-flight probes. For Teflon propellant, T/P = .20 N/kW at 15 km/sec (unsteady mode) and 0.090 N/kW at 20 km/sec (quasi-steady mode). The discharge pressure and temperature predicted by a computational model for polyethylene are consistent with the measured thrust and discharge resistance.

Burton, R. L.↗

Thrust and efficiency of a self-field MPD thruster

Thrust and efficiency of a quasi-steady multi-MW argon MPD thruster are determined for one-millisecond current pulses. Terminal voltage and impulse bit per pulse are measured for a benchmark thruster geometry on a swinging gate thrust stand in a dielectric vacuum tank, at a background pressure of 0.0001 torr, for a range of argon flow rates and arc currents. The quasi-steady thrust data scale quadratically with arc current, and confirm previous estimates of the electromagnetic and electrothermal components of thrust from magnetic and pressure probe measurements. Thruster efficiency is found to increase monotonically with specific impulse, reaching a value of 25% for 4.5 to 6.0 g/sec at 2000 seconds. Results of further experiments show that the inferred specific impulse for voltage fluctuation onset can be increased to 3000 seconds, and the thrust efficiency to above 30%.

Burton, R. L.↗