Search NASA⌕ Search

Engineering topics

Bush, David A.

Publications and source records attributed to Bush, David A..

Fractionated Proton Radiotherapy for Benign Cavernous Sinus Meningiomas

Purpose: To evaluate the efficacy of fractionated proton radiotherapy for a population of patients with benign cavernous sinus meningiomas. Methods and Materials: Between 1991 and 2002, 72 patients were treated at Loma Linda University Medical Center with proton therapy for cavernous sinus meningiomas. Fifty-one patients had biopsy or subtotal resection; 47 had World Health Organization grade 1 pathology. Twenty-one patients had no histologic verification. Twenty-two patients received primary proton therapy; 30 had 1 previous surgery; 20 had more than 1 surgery. The mean gross tumor volume was 27.6 cm{sup 3}; mean clinical target volume was 52.9 cm{sup 3}. Median total doses for patients with and without histologic verification were 59 and 57 Gy, respectively. Mean and median follow-up periods were 74 months. Results: The overall 5-year actuarial control rate was 96%; the control rate was 99% in patients with grade 1 or absent histologic findings and 50% for those with atypical histology. All 21 patients who did not have histologic verification and 46 of 47 patients with histologic confirmation of grade 1 tumor demonstrated disease control at 5 years. Control rates for patients without previous surgery, 1 surgery, and 2 or more surgeries were 95%, 96%, and 95%, respectively. Conclusions: Fractionated proton radiotherapy for grade 1 cavernous sinus meningiomas achieves excellent control rates with minimal toxicities, regardless of surgical intervention or use of histologic diagnosis. Disease control for large lesions can be achieved by primary fractionated proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Proton Therapy: PPAS

The supplier adjusted the process for manufacturing the Short Head Pod section of the Modular Patient Support System in an attempt to eliminate the voids and discontinuities that prevented them from passing the shoot-through clinical requirements, critical to the use of these parts for patient treatment. The remanufactured unit, while an improvement over the previously supplied unit, it still was unable to meet the stringent shoot-through clinical requirements as tested by the LLUMC Medical Physics Laboratory. The vendor was unable to refine the process further, requiring the team to seek alternative solutions. A new replacement, the KVue system provided by Q-Fix, was evaluated by the LLUMC team and found to provide the desired functionality. The remaining funding from this grant was utilized to purchase components of this new system for patient immobilization on the robotic Precision Patient Alignment System.

99 GENERAL AND MISCELLANEOUS↗

Systems and Methods for Injecting Helium Beams into a Synchrotron Accelerator (Final Technical Report)

A research grant was approved to fund development of requirements and concepts for extracting a helium-ion beam at the LLUMC proton accelerator facility, thus enabling the facility to better simulate the deep space environment via beams sufficient to study biological effects of accelerated helium ions in living tissues. A biologically meaningful helium-ion beam will be accomplished by implementing enhancements to increase the accelerator's maximum proton beam energy output from 250MeV to 300MeV. Additional benefits anticipated from the increased energy include the capability to compare possible benefits from helium-beam radiation treatment with proton-beam treatment, and to provide a platform for developing a future proton computed tomography imaging system.

43 PARTICLE ACCELERATORS↗