Search NASA⌕ Search

Engineering topics

C K Shearer

Publications and source records attributed to C K Shearer.

Combining Multi-Faceted Laboratory Studies of 74001-2 and Regional Remote Sensing to Address How Pyroclastic Eruptions Record and Affect the Lunar Volatile Budget

Basaltic magmatism is an efficient process for bringing volatiles from a planetary interior to its surface, with the possibility of generation of a transient lunar atmosphere as abundant volcanic materials de-gassed. However, pyroclastic deposits are locations where trapped gases may be studied [e.g., 2,3]. Volatile-rich pyroclastic deposits occur over a wide surface area of the Moon, indicating that the transport of volatiles and associated pyroclastic materials from the Moon’s mantle to the surface was a wide-spread phenomenon. Numerous studies analyzing remotely sensed data and using empirical modeling have demonstrated that various stages of pyroclastic eruptions significantly influence gas release patterns, morphology, and mineralogy of the deposit. Many observations based on mare basalts and pyroclastic deposits have identified potential histories of gas release [e.g., 2-10] and their influence on volatiles and their stable isotopes [e.g., 11-13]. The best representation of these pyroclastic deposits in the sample collection is core sample 74001-74002 that was collected during the Apollo 17 mission to the Taurus-Littrow Valley (TLV). The double drive tube penetrated a part of a regional-scale pyroclastic deposit and sampled approximately 68.1 cm of that deposit in the TLV. Remnants of this and other pyroclastic depos-its are represented throughout and beyond the TLV [e.g., 14-16]. The stratigraphy of this core has been investigated and defined by numerous studies. The CASA Moon SSERVI research team is conducting a multi-faceted analytical study of this deposit. Data generated from revisiting the stratigraphy of 74001-74002 will be used to place stable isotopes (H, B, Cl, S, Zn, Cu, Rb, Ga, Pb), Ar-Ar and U-Pb chronology, geochemistry, nanometer-scale observations of mineral surfaces, orbital observations, and experiments and modeling within a stratigraphic, eruptive, and geologic context. It is important to place these data into such a context. For example, recent S isotope measurements reported by Dottin et al. show differences within this core that may be related to either changes in source or eruptive process over the course of the eruption (vs. multiple eruptions). A fuller understanding of the stratigraphy is fundamental to resolving this interpretation. This comprehensive approach can only be achieved within the context of a program such as SSERVI. In addition, imaging produced in this project will be incorporated into a citizen scientist program to further identify many of the textural features of this double drive tube.

SSERVI↗

The ANGSA Program: A Low-cost Lunar "Sample Return Mission". An Overview and Progress over the Last 18 Months

The Apollo Program returned 381 kg of samples. Analyses of these samples have provided fundamental insights into the origin and history of the Earth-Moon system and how planets and even solar systems work. These samples have provided ground truth for every post-Apollo mission to the Moon for the interpretation of remotely sensed data. After 50 years of analysis and study, our sophistication for handling and examining samples has greatly increased. Some special samples that were collected or preserved in unique containers or environments remain unexamined by standard or advanced analytical approaches. The Apollo Next Generation Sample Analysis (ANGSA) Program was designed to examine a subset of these special samples. The ANGSA consortium consists of 9 original teams funded by NASA that have combined into a single science team referred to as the ANGSA Science Team. The program was designed to function as the sample analysis portion of a sample return mission with processing, preliminary examination, and analyses utilizing new and improved technologies and recent mission observations. The ANGSA Program links the first generation of lunar explorers (Apollo) with future explorers of the Moon (Artemis). The purpose of this abstract is to highlight the ANGSA samples, science and engineering goals, and progress made so far. Related abstracts and talks will focus on the links between Apollo and Artemis, geologic context, and initial examination, processing, and results.

F M McCubbin↗

Exploring A Lunar Landslide Deposit In The Taurus-Littrow Valley (TLV). Variations In Mineralogy And Mineral Volatile Traps.

The double drive tube core sample (73001/73002), collected at Station 3 during the Apollo 17 mission, penetrated a lunar landslide deposit that was transported from the slope of the South Massif into the TLV (Figure 1). Orbital data suggest that this deposit represents multiple events that were triggered by movement along the Lee-Lincoln scarp [e.g., 1] or impact events [e.g., 2,3]. Although numerous core and trench samples were collected during the Apollo pro-gram and numerous landslide deposits have been identified on the lunar surface by orbital missions [e.g., 3], the Station 3 double drive tube is the only core that penetrated a landslide deposit. The intentions of our study are: to establish the stratigraphy of the deposit; to better understand the processes at work during the event(s), including the role of volatiles in the event(e.g., fluidization-enabled flow, escape of fluidizing volatiles) [1] and the capability of deposits for trapping indigenous volatiles; the number of landslide events; and the trigger(s) of such events. Here, we report some initial petrologic observations of the < 1mm fraction of the regolith. A companion abstract [4] emphasizes <1 mm lithic fragments, compares them to surface lithologies, and to > 4 mm lithic fragments.

M J Cato↗

Initial Petrographic Analysis of Apollo 17 73002 Continuous Core Thin Sections Using QEMSCAN Mapping Techniques

In 1972, the Apollo 17 mission landed in the Taurus-Littrow Valley located in the southeastern edge of Mare Serenitatis [1].During EVA 2at Station 3,a double drive tube was used to collect a sealed core sample (73001/2)of the upper~70cm of the lunar regolith[2-4].The core was taken from the surface of the light mantle deposit, found at the base of the South Massif [3]. For nearly 50 years, the sealed core samples have remained unopened. This study is part of the Apollo Next Generation Sample Analysis (ANGSA) initiative to analyze the continuous thin sections from the Apollo 17 drive tubes opened in 2019[5-7].

QEMSCAN↗

X-Ray Computed Tomography During Preliminary Examination of Apollo Drive Tube 73001

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This began with unsealed core tube 73002 [1,2] that is the upper part of a station 3 double drive tube. More recently the pro-gram extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dis-section [5] of 73001, the lower half of the station 3 double drive tube, that was sealed under vacuum on the Moon. In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) Core Sample Vacuum Container (CSVC). XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube, to ensure it was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into In-Ag alloy). Both scans will provide constraints on future work of this type, particularly for samples collected during the Artemis mission. Another finding from these "engineering" scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection; and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. So far, 92 of the 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition. Because of the dust adhering to particle exteriors it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and basalts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗